Glow-worm F75 fault codewhat it means and how to fix it

Get it checkedBoilerEnergy and Betacom rangesLast reviewed

The boiler saw no pressure rise when the pump started, so it locked out. Almost always the pressure sensor or the pump, not low pressure.

Take care

Some of this is safe to check yourself, but the repair itself is not. If the fault comes back after one reset, stop resetting it and get a Gas Safe registered engineer to look at the Glow-worm properly.

Is the pump running?

The right answer depends on what you can see. Pick the one that matches.

Choose the option on the left that matches what your appliance is doing, and the answer for that case appears here.

No pump noise at all

Pump failure or no signal reaching it. Either way it is inside the case.

Book an engineer rather than resetting.

The pump runs but it still locks out

Most often a failed pressure sensor — an inexpensive part and a short job.

Mention that the pump is audibly running; it saves diagnostic time.

It started right after the system was worked on

Air lock. Trapped air stops the pump generating any pressure change.

Call whoever did the work back to vent it properly.

What F75 means

F75 catches people out because it looks like a pressure fault and is not. When the boiler starts a heating cycle it runs the pump and expects the pressure sensor to register a small rise as circulation begins. If that rise never appears, the board concludes either the pump is not moving water or the sensor is not reading it, and it locks out. The absolute system pressure can be perfectly correct throughout. That is why topping the system up does nothing for F75, and why people spend a weekend refilling a boiler that never had a pressure problem in the first place.

What causes it

Causes of the Glow-worm F75 fault code, most common first
CauseWhat is actually happeningHow likely
Sensor silted with magnetiteGlow-worm mount the transducer where debris naturally settles. Once coated it reports a believable static figure and stops responding to change, which is exactly the condition this code detects.Common
Pump not shifting waterSeized after a summer idle, or worn to the point where it turns without producing useful flow. Frequently arrives with radiators that never quite get hot.Common
Air standing in the pump bodyCommon after a drain-down, a radiator swap, or a refill done at speed. The impeller spins in air and generates nothing for the sensor to see.Occasional
Broken wiring between sensor and boardAn open circuit reads the same as a dead sensor and costs a fraction as much. Worth eliminating before parts are ordered.Occasional

What to try yourself

  1. Read the gauge cold before anything else. A normal 1.0 to 1.5 bar alongside a persistent F75 is the confirmation you need that this is not a low-pressure fault, and it will stop you wasting a weekend refilling.

  2. Work round the radiators bleeding each one, ground floor first and the highest last, then bring the pressure back to 1.2 bar afterwards. Trapped air is the one cause on the list you can clear yourself.

  3. Put a hand on the pipework under the appliance while it tries to start. Warmth spreading within a minute means water is moving; a silent, cold pipe points squarely at the pump.

  4. Reset once. When you book, say the pressure gauge reads normal — on a Glow-worm that single sentence sends the engineer to the transducer rather than round the houses.

    Do not keep resetting. Forcing an appliance to fire with no proven circulation is how heat exchangers get destroyed.

Get a Gas Safe registered engineer to look at your Glow-worm F75

Gas Safe Register engineers only. No obligation.

What it costs to fix

Typical repair cost

£140–£450

Time on site

1 hour

Pressure sensor £140–£220 fitted. Pump £280–£450. System clean, if needed, £400–£700.

Typical UK prices including parts and labour, updated August 2026. Your quote may differ.

Parts you may need

We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.

Vaillant ecoTEC water pressure sensor

0020059717£26–£54Authorised Vaillant parts distributor

Price checked 5 August 2026

Central heating circulating pump

CH-PUMP-15-60£90–£180Plumbing merchant

Price checked 5 August 2026

What other owners found

Nobody has shared what worked for them on this code yet. If you have had it, you would be the first — and it genuinely helps the next person.

Common questions about Glow-worm F75

Will topping up the pressure fix F75?

No, and this is the single most common wasted afternoon with this code. F75 is about the change in pressure when the pump runs, not the absolute value. A boiler sitting at a perfect 1.2 bar throws F75 all day long.

What does the pressure sensor cost?

The part is £25 to £50 and the job is usually under an hour, so most people pay £140 to £220 all in.

Why does it clear sometimes and come back?

A sensor on the way out works intermittently before it fails completely, and an air lock can shift as the system circulates. Either way it is a fault in progress, not one that fixed itself.

Written by

Fault Code Check editorial team

Updated

Reviewed by

Technical reviewer

Gas Safe registration to be displayed on appointment

Last reviewed

Sources and how we verified this

We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.

  • Manufacturer technical and service documentation
  • Interviews with working engineers

Checked by Technical reviewer (Gas Safe registration to be displayed on appointment) on 5 August 2026.

Read our full verification process