Vaillant F.75 fault codewhat it means and how to fix it

Get it checkedBoilerecoTEC plus and pro 2005–2021, ecoTEC exclusive, ecoFIT pure and sustain, ecoTEC sustain and the open-vent ecoTEC plus as F.75; ecoTEC plus CS/1-5 (2022 onwards) as F.075. The D.149 split is published for the 44 and 60 kW ecoTEC plus only.Last updated

The boiler cannot detect a rise in pressure when the pump starts, so it has locked out. Usually a failed pressure sensor or a pump that is not moving water.

Take care

Some of this is safe to check yourself, but the repair itself is not. If the fault comes back after one reset, stop resetting it and get a Gas Safe registered engineer to look at the Vaillant properly.

What happens when the boiler tries to start?

The right answer depends on what you can see. Pick the one that matches.

Choose the option on the left that matches what your appliance is doing, and the answer for that case appears here.

Nothing happens at all — no pump noise

The pump is not running. That is either a seized pump, a failed pump capacitor, or no signal reaching it from the board. All three are engineer jobs inside the case.

Leave it locked out and book an engineer. A seized Vaillant pump is often freed on the bench and replaced the same visit.

The pump runs but the boiler still locks out

The pump is turning but either not moving water or the sensor is not seeing it. In practice this is the failed pressure sensor case most of the time.

A pressure sensor is an inexpensive part and a short job — usually under an hour once the case is off.

It started right after the system was drained or worked on

Almost certainly an air lock. Air in the primary circuit stops the pump generating flow, so no pressure rise is detected.

Whoever did the work should return and vent it properly. This is a ten-minute job for them, not a new fault.

Radiators are cold at the bottom and warm at the top

Classic sludge. Restricted flow through the system stops the pump generating the expected pressure differential, and it will keep tripping until the system is cleaned.

A powerflush or a magnetic filter clean plus inhibitor is the fix. Replacing the sensor alone will not hold.

What F.75 means

F.75 is specific and often misdiagnosed. When the boiler starts a heating cycle it runs the pump and expects the pressure sensor to register a small rise as water begins to circulate. If that rise does not appear, the control board concludes that either the pump is not moving water or the sensor is not reading it, and it locks out. Crucially, F.75 is not the same as F.22. The system pressure can be perfectly correct and still throw F.75, because the fault is about the change in pressure when the pump runs, not the absolute value. That is why topping up the system does not clear it, and why people spend a weekend refilling a boiler that never had a pressure problem. How much the boiler itself can tell the engineer depends on the model.

On the domestic ecoTEC plus and pro, F.75 is one row — "insufficient pressure jump detected when starting the pump" — followed by a checklist: the water pressure sensor, the pump for a blockage, the circuit for air and enough water, the adjustable bypass, and an external expansion vessel, which Vaillant say must be connected at the return. The ecoFIT pure and ecoFIT sustain manuals print the same code more bluntly as "pressure sensor: pressure switch defective".

Only the 44 and 60 kW ecoTEC plus, the VU 446 and 606/5-5, go further: their manual sends the engineer to diagnostics code D.149, which splits F.75 into seven findings — pump blocked, electrical pump fault, pump dry running, pressure sensor fault, no feedback from the pump, an incorrect pump detected, and insufficient flow at the end of the purge programme, for which the manual wants a filling pressure at least 0.2 bar above the expansion vessel charge. If you have one of those, ask what D.149 read; if you have an ordinary combi, the checklist is the whole of Vaillant's guidance and the engineer works through it. Either way, someone who replaces the pressure sensor on the strength of the code alone is guessing.

What causes it

Causes of the Vaillant F.75 fault code, most common first
CauseWhat is actually happeningHow likely
Failed pressure sensorBy some distance the most common cause. The sensor sits on the return pipework inside the boiler and its readings drift or stop entirely as it ages.Common
Seized or failing pumpThe pump spins but moves little water, or does not start at all. Often accompanied by radiators that get warm at the top only, or by a boiler that gets hot very quickly then cycles off.Common
Air lock in the pump or primary circuitTrapped air stops the pump generating flow, so no pressure change is seen. Common after a repair or after the system has been drained.Occasional
Blocked heat exchanger or filterSludge restricts flow enough that the pump cannot generate the expected pressure differential. Usually accompanied by cold spots low on radiators.Occasional

What to try yourself

  1. Check the pressure gauge first, cold. If it reads between 1.0 and 1.5 bar, the system pressure is fine and the fault is genuinely F.75 rather than a low-pressure problem in disguise.

  2. Put your hand on the pipework immediately below the boiler when it tries to fire. If nothing warms and you hear no circulation, the pump is a strong suspect.

  3. Reset the boiler once, using the press for your range — one second on the fault clearance key of a 2012 to 2021 ecoTEC plus, pro or ecoFIT, longer than three seconds on an ecoTEC sustain or a CS/1-5. If F.75 returns within the same heating cycle, stop resetting — the fault is real.

    Repeated resets on F.75 can run the boiler with poor circulation, which is exactly the condition that damages heat exchangers.

Get a Gas Safe registered engineer to look at your Vaillant F.75

We do not pass enquiries to a repair firm, so there is no form here. Find a Gas Safe registered engineer through the Gas Safe Register, and ask to see their registration card when they arrive — it is the register, not the van, that tells you they are qualified.

What it costs to fix

Typical repair cost

£140–£320

Time on site

1 hour

Pressure sensor replacement is typically £140–£220 fitted. A pump is £280–£450. A powerflush, if the system is sludged, is £400–£700 and is a separate job.

Typical UK prices including parts and labour, updated September 2026. Your quote may differ.

Parts you may need

We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.

Vaillant ecoTEC water pressure sensor

0020059717£26–£54Authorised Vaillant parts distributor

Price checked 28 September 2026

Central heating circulating pump

CH-PUMP-15-60£90–£180Plumbing merchant

Price checked 28 September 2026

Own this appliance and had this code? . Nothing is published until a person has read it.

Common questions about Vaillant F.75

Is F.75 the same as low pressure?

No, and this is the single most common mistake with this code. F.22 means the absolute pressure is too low. F.75 means the pressure did not change when the pump started. A boiler sitting at a perfect 1.2 bar can show F.75 all day, and topping it up will not clear it.

How much does the pressure sensor cost to replace?

The part itself is usually £25 to £50. With labour, most people pay £140 to £220 for the job, and it is typically done inside an hour on the first visit if the engineer carries the part.

Can I replace the pressure sensor myself?

No. It sits inside the sealed casing of a gas appliance, and opening that casing is work only a Gas Safe registered engineer may legally carry out. It is also a wet job on a pressurised system.

Why does F.75 sometimes clear on its own?

A failing sensor often works intermittently before it fails completely, and an air lock can shift on its own as the system circulates. Both mean the fault is coming back. An F.75 that comes and goes is a sensor on the way out, not a fault that fixed itself.

Written by

Andrew Pickett

Researcher and writer

Last updated

Technical review

Not reviewed by an engineer

No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.

What we check instead

Sources and how we verified this

We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.

  • Manufacturer technical and service documentation
  • Manufacturer support portal

This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.