Vaillant F.22 fault codewhat it means and how to fix it

Get it checkedBoilerAll ecoTEC models, 2005 onwardsLast reviewed

The boiler has shut down because there is not enough water in the system. Pressure has dropped below roughly 0.5 bar and it will not fire until you top it up.

Take care

Some of this is safe to check yourself, but the repair itself is not. If the fault comes back after one reset, stop resetting it and get a Gas Safe registered engineer to look at the Vaillant properly.

What does the pressure gauge read right now, with the boiler cold?

The right answer depends on what you can see. Pick the one that matches.

Choose the option on the left that matches what your appliance is doing, and the answer for that case appears here.

The gauge reads zero or is in the red

The system has lost a significant amount of water, which means an active leak rather than gradual loss. Top up to 1.2 bar so you have heating tonight, but book someone to find it.

Check under the boiler, around every radiator valve, and around the airing cupboard for damp before you refill — finding the leak while the pressure is low is much easier.

The gauge reads between 0.1 and 0.8 bar

Normal slow loss. Top up to 1.2 bar and reset. If it has been a year or more since you last did this, nothing is wrong.

Note the date. Topping up more than twice a year is a leak, not maintenance.

The gauge reads 1.0 bar or higher and F.22 is still showing

The pressure is fine, so the sensor reading it is not. That is either a failed pressure sensor or a blockage stopping water reaching it, and it needs an engineer.

Do not keep resetting. The boiler is refusing to fire because it believes it has no water, and repeatedly overriding that is how heat exchangers get destroyed.

It drops again within days of topping up

That rate of loss is a real leak or a failed expansion vessel. Continually refilling introduces fresh oxygenated water, which corrodes the system from the inside.

Stop topping up and get it diagnosed. A pressure test takes an engineer under an hour.

What F.22 means

F.22 is a dry-fire protection lockout. Vaillant boilers measure system pressure continuously, and if it falls below about 0.5 bar the control board stops the burner before the heat exchanger can run without enough water passing through it. Running a heat exchanger dry destroys it in minutes, so this cut-out is doing exactly what it should. The pressure loss itself is the actual fault. A sealed heating system is closed: the water in it has nowhere to go, so if the gauge is falling, water is leaving somewhere. That might be a slow weep from a radiator valve, a pinhole in pipework under the floor, or a failed expansion vessel pushing water out through the pressure relief valve every time the system heats up.

What causes it

Causes of the Vaillant F.22 fault code, most common first
CauseWhat is actually happeningHow likely
Water lost from the sealed systemA weeping radiator valve, a joint under the floor, or a leaking towel rail. Slow enough that you never see a puddle, fast enough to drop the gauge over a few weeks.Common
Air bled out of radiators without topping back upEvery time you bleed a radiator you remove volume from the system. Bleed six radiators and the gauge drops noticeably.Common
Failed expansion vesselThe vessel absorbs the expansion of heating water. When its internal bladder fails, pressure spikes on heating and dumps out through the pressure relief valve, so the system loses a little every cycle.Occasional
Passing or corroded pressure relief valveDebris on the seat holds the valve slightly open. Look for a copper pipe outside the wall near the boiler that drips or shows limescale staining.Occasional

What to try yourself

  1. Look at the pressure gauge on the boiler or on the pipework beneath it. Cold, it should read between 1.0 and 1.5 bar. If the needle is in the red or near zero, that is your fault confirmed.

  2. Find the filling loop — usually a braided silver hose with a valve at each end, underneath the boiler. On some Vaillant units it is an internal loop operated by a blue or grey key slot at the base.

  3. Open both valves slowly. You will hear water flowing. Watch the gauge and close them as soon as it reaches 1.2 bar.

    Do not overfill. Above 2.5 bar cold you risk the pressure relief valve dumping water, and you will be back where you started.
  4. Close both filling loop valves fully and reset the boiler by holding the reset button for three seconds.

  5. Write the date and the pressure on a sticky note by the boiler. Check it again in a week. If it has dropped again, you have a leak and it needs finding rather than topping up.

Get a Gas Safe registered engineer to look at your Vaillant F.22

Gas Safe Register engineers only. No obligation.

What it costs to fix

Typical repair cost

£0–£450

Time on site

10 minutes

Topping up costs nothing and takes five minutes. If it will not hold, expect £90–£160 for a leak trace, £150–£280 to replace an expansion vessel, and up to £450 if pipework has to be lifted.

Typical UK prices including parts and labour, updated August 2026. Your quote may differ.

Parts you may need

We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.

Expansion vessel (8 litre, sealed system)

EV-8L£35–£85Plumbing merchant

Price checked 5 August 2026

Pressure relief valve, 3 bar

PRV-3B£18–£42Plumbing merchant

Price checked 5 August 2026

What other owners found

Nobody has shared what worked for them on this code yet. If you have had it, you would be the first — and it genuinely helps the next person.

Common questions about Vaillant F.22

Can I just keep topping it up?

For a while, but it is a bad idea. Every refill brings fresh oxygenated water into a sealed system, and that is what causes internal corrosion and radiator sludge. Topping up twice a year is normal. Twice a month means you have a leak that will cost more the longer it runs.

What pressure should a Vaillant boiler be set to?

Between 1.0 and 1.5 bar with the system cold, and 1.2 bar is the usual target. It will read higher when the heating is running — up to about 2.0 bar is normal and nothing to worry about. Set it cold, never hot.

Why does F.22 come back every winter?

Cold weather makes you bleed radiators, and bleeding removes water. It also means the system runs more hours, so any slow leak loses more. A boiler that only shows F.22 in January usually has a small leak that stays hidden the rest of the year.

Is F.22 dangerous?

The lockout itself is a safety feature working correctly, so no. What matters is not defeating it. If the boiler will not hold pressure, leave it locked out and get it looked at rather than resetting repeatedly to force it to fire.

Written by

Fault Code Check editorial team

Updated

Reviewed by

Technical reviewer

Gas Safe registration to be displayed on appointment

Last reviewed

Sources and how we verified this

We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.

  • Manufacturer technical and service documentation
  • Manufacturer support portal
  • Interviews with working engineers

Checked by Technical reviewer (Gas Safe registration to be displayed on appointment) on 5 August 2026.

Read our full verification process