On a Viessmann the control unit decides what the display shows, not the boiler name, so the first thing to find is not "Vitodens 100-W" but the type designation printed after it. It is on the type plate, which on a wall-hung Vitodens sits on the top panel beside the flue connection (a second copy of the QR label is meant to be stuck inside the front of the operating instructions), and it reads WB1A, WB1B, WB1C, B1HA, B1HC, B1HF and so on for the 100-W; B1LA to B1LG for the 111-W; BPJD, B0HA or B0KA for the 050-W; B2HA, B2HB or B2HF for the 200-W. That designation picks the fault table. The two-character generations (WB1B through B1HC, 111-W B1LA to B1LD, 050-W BPJD) share one table with small differences: WB1B editions have no E3 row, the storage-combi 111-W has no 52/5A flow-sensor rows, the 2016-on B1HC adds 0A, 0C, A3 and b7. The 2020-on units with the black-and-white arrow-key programming unit (100-W B1HF/B1KF, B1HG and B1GA, 111-W B1LF/B1LG, and the 050-W B0HA from 2023) use a completely different numeric table — F.14, F.62, F.980 — in which a bare "E 3" on the home screen is the holiday programme, not the safety-chain fault of the same name. The Vitotronic-controlled 200-W, 222-F and 242-F print a sentence plus a code, report a failed ignition as EE rather than F4, and carry Lambda Pro combustion-controller calibration codes (E1, E2, E7, E8, EA, Eb) that no 100-W has. Viessmann distinguish a burner that is "blocked" (it waits for the condition to clear and restarts by itself) from a burner "in a fault state" (locked out until you reset it), and their instruction on resets is quoted here rather than softened: if faults are not rectified they can have life threatening consequences; do not reset the burner several times in quick succession; notify your heating contractor if a fault recurs. Viessmann publish no permitted number of resets. Their UK Fault Code Checker covers around a dozen entries; the tables that follow are from the installation and service instructions for each unit, which is the only place the full lists exist.

Where the code shows on a Viessmann

Vitodens 100 WB1A and 100-W WB1A (2004 to 2008): a two-character code flashes with the fault symbol and the Reset key lights up. WB1B, WB1C, B1HA/B1KA and 111-W B1LA/B1LB (2008 to 2016): the code flashes with a wrench symbol on the small LCD between the two rotary selectors; the system-pressure reading flashes instead when pressure is low. B1HC/B1KC and 111-W B1LD (2016 to 2020): a touch panel; the wrench flashes with the code, and when "R" also appears the burner is locked out. 050-W BPJD (2018 to 2023): a lower-priority fault shows the code steady with the warning triangle flashing, a higher-priority one flashes both. B1HF/B1KF, B1HG, B1GA and 111-W B1LF/B1LG (2020 on) and 050-W B0HA (2023 on): the same black-and-white programming unit on all of them shows a warning triangle with the fault code; a locked-out burner shows a "CL" glyph and the triangle flashes; the number itself is reached with the up and down arrows, and the last five faults are kept under "b.4". Viessmann write the numbers as F.14, F.62, F.980 in the instructions. Vitotronic 100 HC1B / 200 HO1B (200-W B2HA/B2HB, 222-F B2TA, 242-F B2UA): a red fault indicator, a plain-text description and the code beside it ("Outside t sens 18"), with a fault history under the menu. E3-platform 200-W B2HF and 222-F B2TF: F.xxx codes on a 3.5-inch black-and-white screen or a 7-inch colour touchscreen. Whatever the unit, write down the number; the symbol is the same for every fault.

How to reset a Viessmann

There is no single Viessmann reset, and the wrong one changes a setting rather than clearing a lockout. WB1A: press the illuminated Reset key. WB1B, WB1C, B1HA/B1KA and 111-W B1LA/B1LB: turn the heating rotary selector to the RESET position for less than two seconds, then back into the control range. B1HC/B1KC and 111-W B1LD: touch "R" for approximately two seconds. 050-W BPJD: press MODE and OK simultaneously; the display shows three dashes while it resets. B1HF/B1KF, B1HG, B1GA, 111-W B1LF/B1LG and 050-W B0HA: use the arrows to show the fault number, note it, then hold the up and down arrows together for approximately four seconds until a rotating bar appears; Viessmann add that a reset is only possible after the burner has cooled down. Vitotronic 100 HC1B / 200 HO1B: press reset button R on the control unit. E3-platform 200-W B2HF/B2KF and 222-F B2TF: a menu action called Unlock — select Unlock on the home screen and confirm with OK, or Active messages, Burner fault, Unlock. Only codes whose table row says "Burner in a fault state" need a reset at all; a "Burner blocked" code restarts itself when the cause is gone, and a "Constant" or "Continuous operation" code means the boiler is still running on a fallback. On every unit Viessmann say the same thing: do not reset repeatedly, and if it comes back, call your heating contractor.

Most common Viessmann faults

The Viessmann codes people look up most.

Every Viessmann fault code

56 published codes. Filtering happens in the page — every one is in the HTML.

Showing 56 of 56 codes

Every published Viessmann fault code with its meaning and severity
CodeWhat it meansSeverity
F4No flame signal was detected during burner start on any two-character Vitodens, so the burner has locked out. Reset once; if it returns, call a Gas Safe engineer.Stop — call an engineer
F.74System pressure too low on a 2020-on Vitodens with the numeric display. The burner and pump stop until the pressure is back. Viessmann tell the householder to top up below 1.0 bar.Get it checked
F.65No flame signal at burner start on a 2020-on Vitodens — the numeric table's equivalent of F4. Burner locked out. Check the gas is on, reset once; if it returns, call a Gas Safe engineer.Stop — call an engineer
EAA Lambda Pro combustion-controller code on Vitotronic-controlled 200-W, 222-F and 242-F boilers: the ionisation current during calibration was outside the permissible range or implausibly different from last time. Lockout; engineer.Stop — call an engineer
F2The temperature limiter has responded — the boiler water got hot enough to trip the safety chain. Viessmann want the fill level, pump and limiter checked before any reset.Stop — call an engineer
F.62The high limit safety cut-out has tripped on a 2020-on Vitodens: the boiler water got too hot and the burner is locked out. A Gas Safe engineer checks circulation, fill level and diverter valve.Stop — call an engineer
F3The control unit saw a flame signal before it had opened the gas — a flame where there should be none, or a false signal from the ionisation electrode. Lockout; Gas Safe engineer.Stop — call an engineer
A9On a 100-W, 111-W or 050-W, A9 is a communication error with the OpenTherm room controller: the boiler carries on heating without it. On a 242-F it means the internal pump is blocked.Usually simple to fix
E3A fault in the safety chain — the temperature limiter circuit has opened or its wiring has failed. Not a sensor fault; a Gas Safe engineer checks the limiter and control unit.Stop — call an engineer
F.87System pressure too high on a numeric-display Vitodens. Burner and internal pump stop. Usually an overfilled system or a flat expansion vessel; the contractor checks vessel charge and the pressure sensor.Get it checked
F1Maximum flue gas temperature exceeded. The flue gas sensor has seen the heat exchanger run too hot, almost always because water is not moving through it. Lockout; engineer.Stop — call an engineer
F9Fan speed too low during burner start. The control unit will not release gas until the fan proves it is turning fast enough, so the burner has locked out. Engineer job.Get it checked
30Boiler water temperature sensor fault: 30 is a short circuit, 38 a lead break. The burner is blocked until the sensor reads plausibly again. Engineer replaces the sensor.Get it checked
E5Viessmann call E5 an "internal fault" but their only instruction is to check the ionisation electrode and its cables — a flame-monitoring fault, blocked not locked, and one for a Gas Safe engineer.Get it checked
F.71Fan fault on a 2020-on Vitodens: F.71 and F.371 speed too low, F.72 fan still turning, F.457 sluggish or blocked, F.349 air flow not detected. Burner locked out; an engineer checks the fan unit.Get it checked
F.75No flow rate detected through a 2020-on Vitodens. Viessmann start with top up and vent; if it recurs the engineer checks the boiler isolating valves, flow sensor and pump.Get it checked
F.63The flue gas temperature limiter has tripped on a 2020-on Vitodens and the burner is locked out. Reset only once the flue has cooled; the cause is a circulation check for a Gas Safe engineer.Stop — call an engineer
F.89The internal circulation pump of a 2020-on Vitodens is blocked (F.89), reporting an electrical fault (F.799) or running dry (F.982). No heating or hot water until it is freed or replaced by an engineer.Get it checked
F.352The combustion controller measured carbon monoxide above its limit on a 2020-on Vitodens and locked the burner out. Leave it off. The whole flue gas path is inspected by a Gas Safe engineer.Stop — call an engineer
F.357Insufficient gas supply on a 2020-on Vitodens. F.353 is the softer version with output reduced; F.467, F.383 and F.384 blame calibration or a contaminated gas line. Check the gas is on, then call an engineer.Get it checked
F.359No ignition spark on a 2020-on Vitodens, so the burner locked out before it could light. Ignition electrode, ignition module or heat management unit: a Gas Safe engineer's diagnosis.Stop — call an engineer
F.381Flame lost while the burner was running on a 2020-on Vitodens and it has locked out; F.378 is the same event. The gas supply, flue and ionisation electrode are for a Gas Safe engineer.Stop — call an engineer
F.540Condensate has backed up into the heat cell of a 2020-on Vitodens; F.176 is the same finding on the 100-W and 111-W. Burner locked out. The condensate trap and drain need clearing by an engineer.Get it checked
F0Internal fault in the burner control unit. Viessmann's only measure on the two-character units is "Replace control unit"; the Vitotronic B2HB allows one reset first. Not a householder repair.Get it checked
E6System water pressure too low — a code only on the WB1A, early WB1B and Vitotronic 200-W. Viessmann's measure is to top up with water; later 100-W units show the flashing pressure instead.Get it checked
F.59Mains undervoltage on a 2020-on Vitodens: the burner locks out and the pump stops until the supply recovers. If the voltage is good and it recurs, Viessmann replace the fan unit.Get it checked
F.64Flame loss on a 2020-on Vitodens that the boiler recovered from by itself — a message, not a lockout. Worth a service visit before it becomes F.381; not a reason to reset anything.Get it checked
F.67Ionisation current outside its permitted range on a 2020-on Vitodens; F.69, F.350 and F.351 are the same finding. The burner locks out until the electrode, gas supply and fan unit are checked by an engineer.Get it checked
F.70An internal fault in the HBMU heat management unit of a 2020-on Vitodens. Nearly twenty numbers say the same: reset once, and if it returns the unit is replaced. Engineer only.Get it checked
F.345Temperature limiter responded on a 2020-on Vitodens, but this row releases itself after cooling. Heat is not getting away from the boiler: check pressure and bleed radiators, and call an engineer if it keeps happening.Get it checked
F.346The combustion controller on a 2020-on Vitodens could not calibrate its ionisation current. F.372, F.464, F.468 and F.377 lock out; F.374 to F.376 restart by themselves. Gas supply, electrode, flue and condensate: engineer's checks.Stop — call an engineer
F.369The flame lit and was lost within the safety time on a 2020-on Vitodens; F.380 is the same row. Burner locked out. Gas supply, flue recirculation and the ionisation electrode need a Gas Safe engineer.Stop — call an engineer
F.980Hot water stopped on a 2020-on Vitodens because the boiler could not get enough flow through itself before (F.980) or during (F.981) cylinder heating. Heating carries on. Cylinder valves, air and pump for the engineer.Get it checked
F8The gas train closed later than the control unit expected when the burner shut down. Viessmann treat it as a gas valve fault: lockout, no reset by the householder, Gas Safe engineer.Stop — call an engineer
FdBurner control unit fault, which Viessmann first blame on the ignition electrodes, their cables or electrical interference, and only then on the unit. FF is the same row. Engineer job.Get it checked
50Cylinder temperature sensor fault — 50 short circuit, 58 lead break. Heating continues; hot water from the cylinder stops until the sensor or its lead is replaced. Not a safety fault.Usually simple to fix
b0Flue gas temperature sensor fault — b0 short circuit, b8 lead break. The burner is blocked until the sensor reads plausibly, because it is part of the flue overheat protection. Engineer job.Get it checked
F.95The OpenTherm room controller a 2020-on Vitodens expects is not connected (F.95) or connected but not configured (F.738). On a 100-W or 111-W the burner will not run; the 050-W carries on.Get it checked
F.347Flue gas recirculation detected on a 2020-on Vitodens — exhaust is getting back into the combustion air. F.463 adds contaminated air. Burner locked out; flue inspection by a Gas Safe engineer.Stop — call an engineer
FAThe fan did not come to rest when the control unit expected it to — "fan idle state not reached". A lockout on the fan or its control, for an engineer.Get it checked
FCOn a 100-W, 111-W or 050-W the electrical fan control in the control unit is faulty. On a Vitotronic 200-W the same letters mean a gas train or blocked flue fault. Engineer either way.Get it checked
10Outside temperature sensor fault — 10 short circuit, 18 lead break. The boiler keeps heating, in constant-temperature mode rather than weather-compensated. Not urgent; an engineer replaces the sensor.Usually simple to fix
51DHW outlet temperature sensor fault on a combi: 51 short circuit, 59 lead break. Heating continues but hot water stops, because the boiler cannot see the tap temperature it is controlling.Usually simple to fix
52Flow sensor fault on a 100-W combi: 52 is a short circuit, 5A a lead break. The burner is blocked, because the boiler cannot tell whether a tap is running. Engineer job.Get it checked
F.68A flame signal was present before the burner started on a 2020-on Vitodens, which should be impossible, so it locked out. F.355 is the electronic version. Engineer only.Stop — call an engineer
F.102The WiFi communication module of a 2020-on Vitodens has lost contact: F.102 on the fault list, E10 or E12 during connection. Heating is unaffected; only the ViCare app link is down.Usually simple to fix
F.370The gas or modulation valve on a 2020-on Vitodens did not close when told to; burner locked out. F.365 to F.367 are the control side. Leave the boiler off; call a Gas Safe engineer.Stop — call an engineer
F.471The system pressure sensor is missing, open-circuit or shorted on a 2020-on Vitodens, so the boiler will not run at all. A sensor and lead check for the engineer.Get it checked
F5On the first-generation Vitodens 100 WB1A only, F5 is a faulty air pressure switch. No later Viessmann control unit has an F5 row; if yours shows one, check the type plate.Get it checked
FFOn the two-character units FF is the same burner control unit fault as Fd. On a Vitotronic 200-W it means an internal fault or a disabled reset key, and Viessmann say restart the appliance.Get it checked
0AOn the B1HC-generation 100-W and 111-W, 0A means a fitted CO limiter has responded to carbon monoxide, or a fitted gas pressure switch has seen gas pressure fall. Switch off; Gas Safe engineer.Stop — call an engineer
0CMains voltage too low. The burner is blocked while the supply is out of range and restarts on its own when it recovers. Viessmann's measure on the WB1A is to contact the electricity supplier.Get it checked
A3Flue gas temperature sensor incorrectly positioned — the sensor test at burner start saw no flame heat. Burner blocked. Viessmann: refit the sensor correctly and repeat the test.Get it checked
b7On the B1HC-generation 100-W and 111-W, b7 is emergency mode after a control unit fault and Viessmann say to switch the boiler off and on. On a Vitotronic unit it is a coding card fault.Get it checked
F.299Real-time clock fault on a 2020-on Vitodens: the date and time are wrong. Set them again from the menu; if the boiler keeps losing time, the heat management unit's clock has failed.Usually simple to fix
F.387Earth fault in the ionisation (flame-monitoring) circuit on a 2020-on Vitodens; F.385, F.395, F.399, F.401, F.403 and F.405 are the same family. Electrode first, heat management unit if it persists. Engineer job.Get it checked

Viessmann models

Codes can differ between generations. Check yours.