Viessmann F.59 fault codewhat it means and how to fix it
Mains undervoltage on a 2020-on Vitodens: the burner locks out and the pump stops until the supply recovers. If the voltage is good and it recurs, Viessmann replace the fan unit.
Take care
Get a Gas Safe registered engineer to look at your Viessmann F.59
We do not pass enquiries to a repair firm, so there is no form here. Find a Gas Safe registered engineer through the Gas Safe Register, and ask to see their registration card when they arrive — it is the register, not the van, that tells you they are qualified.
What F.59 means
F.59 reads "Burner locked out, boiler circuit pump off. No central heating, no DHW heating — Power supply, undervoltage — Check mains voltage. If voltage is correct and the fault occurs repeatedly, replace the fan unit." The B1HG table gives the cause as "Undervoltage, HBMU heat management unit" and the 050-W B0HA/B0KA and B1GA as "Undervoltage, power supply", with the same measure. The boiler's electronics need a supply within tolerance to drive the gas valve and fan safely, and when the mains sags — a brown-out, a long extension of the house wiring, a loose neutral, a neighbour's welder — the unit stops rather than run the burner on a supply it cannot trust. It should recover when the voltage does; the row lists no reset.
The fan unit appearing as the remedy surprises people. On these boilers the fan carries its own drive electronics and reports back to the heat management unit, and a fan whose electronics have begun to fail can present as a supply that keeps dipping. Viessmann make the contractor measure the mains first, and only replace the fan if the supply is proven good and the fault persists. There is no householder step in the operating instructions for F.59 itself; the "heating system is off" checks — ON/OFF switch, mains isolator, the MCB — are for a boiler with no power at all, not one complaining about low voltage. If lights in the house dim when large appliances start, the supply is the suspect and the electricity network operator, not the heating contractor, may be who to call. The two-character B1HC/B1KC reports the same condition as 0C, "Insufficient power supply".
What causes it
| Cause | What is actually happening | How likely |
|---|---|---|
| Mains supply sagging | Low voltage at the socket during peak demand, a poor connection in the house wiring, or a supply fault outside. The first thing measured. | Common |
| Fan unit electronics | Viessmann's remedy when the voltage is correct and F.59 recurs: replace the fan unit. | Occasional |
| Boiler on an overloaded circuit or long extension | A spur shared with heavy loads, or a fused spur with a poor terminal. Shows as dips only when something else runs. | Occasional |
| HBMU heat management unit | The B1HG table names the unit in the cause. Rare; reached after the supply and fan are cleared. | Rare |
Can you fix it yourself?
Stop — this needs an engineer
What it costs to fix
Typical repair cost
£0–£320
Time on site
1 hour
A supply dip costs nothing. A wiring fault is an electrician's visit; a fan unit is the top of the range.
Typical UK prices including parts and labour, updated September 2026. Your quote may differ.
Parts you may need
We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.
Viessmann Vitodens fan
£150–£300Authorised Viessmann parts distributor
Price checked 28 September 2026
Viessmann burner control unit (control unit PCB / HBMU heat management unit)
£250–£500Authorised Viessmann parts distributor
Price checked 28 September 2026
Own this appliance and had this code? . Nothing is published until a person has read it.
Related Viessmann fault codes
- F0Get it checkedInternal fault in the burner control unit. Viessmann's only measure on the two-character units is "Replace control unit"; the Vitotronic B2HB allows one reset first. Not a householder repair.Related: electronics and power
- F.70Get it checkedAn internal fault in the HBMU heat management unit of a 2020-on Vitodens. Nearly twenty numbers say the same: reset once, and if it returns the unit is replaced. Engineer only.Related: electronics and power
- FdGet it checkedBurner control unit fault, which Viessmann first blame on the ignition electrodes, their cables or electrical interference, and only then on the unit. FF is the same row. Engineer job.Related: electronics and power
- FFGet it checkedOn the two-character units FF is the same burner control unit fault as Fd. On a Vitotronic 200-W it means an internal fault or a disabled reset key, and Viessmann say restart the appliance.Related: electronics and power
- 0CGet it checkedMains voltage too low. The burner is blocked while the supply is out of range and restarts on its own when it recovers. Viessmann's measure on the WB1A is to contact the electricity supplier.Related: electronics and power
- b7Get it checkedOn the B1HC-generation 100-W and 111-W, b7 is emergency mode after a control unit fault and Viessmann say to switch the boiler off and on. On a Vitotronic unit it is a coding card fault.Related: electronics and power
Own a Viessmann boiler? Save it and its codes come first next time.
Related guides
Technical review
Not reviewed by an engineer
No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.
Sources and how we verified this
We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.
- Manufacturer technical and service documentation
This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.