Potterton boiler fault codes

Potterton boilers are built by Baxi Heating UK, and since 2023 the Potterton website has forwarded to baxi.co.uk, so an owner searching for help lands on Baxi pages that never mention their badge. The manuals do still exist, and they are what these pages are written from: the Promax, Titanium and Gold guides for the boilers with a rotary switch, the Assure and Promax Ultra guides for the ones with a proper digital display, and the Heat-only manuals for the ranges that flash a light instead. The platform under the casing is shared — a Potterton Assure and a Baxi 600 are the same appliance with different badges — but Potterton documented every range in its own name, and where a Potterton manual says something different from the Baxi one, this site follows the Potterton one. There is more variation between Potterton generations than between brands: E28 has had three different meanings on Potterton combis since 2007, and the code for low water pressure changed from E119 to E118 when the display changed. Find your display type below before you look up a number.

Where the code shows on a Potterton

Three systems, and the front of the boiler tells you which. A two-character window beside a rotary ON/OFF/RESET knob is the Promax, Titanium, Gold and Heatmax family (2007–2019): three-digit codes are shown in halves, "E1" then "33" for E133, and Potterton's guides spell this out because owners report E1 as the fault. A larger digital screen with a separate Reset button and a spanner symbol is the Assure Combi and System and the Promax Ultra (2015–2023): the code is a flashing number, 118 or 133, with a spanner when you cannot clear it yourself and an R when you can, and low pressure is 118 rather than 119. No display at all but an illuminated button that flashes green or red is a heat-only boiler — Assure Heat, Titanium Heat, Ultra Heat — where the count of red flashes is the code. Older heat-only Promax HE Plus, Promax SL and Gold Heat boilers have three small LEDs whose on/off/flash pattern is read against a table in the installer's manual; those and the Suprima's neon codes are described at the bottom of this page rather than given pages of their own.

How to reset a Potterton

Different for each display, and the hold time is not interchangeable. Rotary-switch boilers (Promax, Titanium, Gold, Heatmax): turn the selector knob fully anticlockwise against the spring to the Reset position and hold it there for at least five seconds — Potterton's wording in every one of those manuals — and only E110, E130 and E133 respond; E119 clears itself when the pressure is restored. Digital-display boilers (Assure, Promax Ultra): press the Reset button for one to three seconds according to the installation manual; the Assure user guide says approximately one second and warns that holding it for more than two seconds will not reset the boiler, so a long press is the wrong instinct here. The same user guide's flowchart says "press and hold for 5 seconds", which contradicts its own instruction two pages later; the one-to-three-second figure appears in every installer manual and is the one to trust. Heat-only boilers with the flashing button: hold Reset until the flashing speeds up and goes out, five seconds in the Ultra Heat user guide, and the boiler allows five resets in an hour before it must be powered off and on. On every range Potterton's advice after a reset that does not hold, or a code that comes back regularly, is the same: stop and contact your installer or Baxi Customer Support, which is who answers for Potterton now.

Most common Potterton faults

The Potterton codes people look up most.

Every Potterton fault code

28 published codes. Filtering happens in the page — every one is in the HTML.

Showing 28 of 28 codes

Every published Potterton fault code with its meaning and severity
CodeWhat it meansSeverity
E119The sealed system on a rotary-switch Potterton — Promax, Titanium, Gold, Heatmax — has dropped below half a bar. The window shows E1 and then 19. Fill to 1–1.5 bar and it clears itself.Get it checked
E133Gas supply interrupted, ignition failed or no flame detected — every Potterton generation. Confirm the gas supply, one reset (5 s on the knob, 1–3 s on the button), and call if it returns.Get it checked
E118The digital-display Pottertons — Assure Combi, Assure System, Promax Ultra — have dropped below half a bar on the heating circuit. Repressurise to 1–1.5 bar and the boiler restarts on its own.Get it checked
E110Safety thermostat operated — the primary water overheated — on every Potterton code display. One reset is permitted (5 s knob or 1–3 s button); a second E110 is a circulation fault for an engineer.Get it checked
E125Circulation fault (primary circuit) on every Potterton code display — the water did not warm as expected after lighting, or overshot twice. Pump, air or sludge; an engineer job after one reset.Get it checked
E28Three meanings on Potterton: incorrect PCB fitted (Gold Combi HE 2007), flue NTC fault (2008–2014 and all digital displays), or flue NTC, air pressure switch, blocked flue or condensate (2015–2019 combis).Get it checked
E128Flame failure during normal operation on the Potterton Assure and Promax Ultra: the burner was lit and went out. Resettable; recurring E128 wants an engineer.Get it checked
E130Flue NTC operated — the flue gas got too hot — on every Potterton code display. Reset once as the user guide allows; if it returns the heat exchanger or flue needs an engineer.Get it checked
E160Fan or fan wiring fault on every Potterton code display: the fan did not start or reach speed. A component fault in the user guide's words — note it and call; no reset is offered.Get it checked
E20Central heating NTC fault on every Potterton code display — the flow temperature sensor is open or short circuit. The user guide says note the code and call; no reset is offered.Get it checked
E193The rotary-switch Pottertons' pre-ignition pump check has failed: the pump ran and the flow never proved. Same causes as E125; no owner reset is offered.Get it checked
E135The Assure and Promax Ultra's internal-error ignition code: the control blames its own side of the gas valve rather than the supply for the flame that never came. One reset; then an engineer.Get it checked
E50Hot water NTC fault on rotary-switch Potterton combis — Promax Combi, Titanium, Gold Combi, Store, Heatmax. The domestic hot water sensor is open or short. Note the code and call.Get it checked
E109The digital-display Pottertons' pre-ignition pump check — Assure Combi, Assure System, Promax Ultra. The flow never proved, so the burner was not lit. Bleed and check pressure; then an engineer.Get it checked
E117Primary water pressure above 2.7 bar on the Potterton Promax Ultra. Usually an over-filled system or a failed expansion vessel; an engineer should let it down and find out which.Get it checked
E09The Assure and Promax Ultra's gas valve connection cable fault: the board has lost its wiring link to the valve. Resettable once; recurring 09 is a wiring or PCB job.Get it checked
Red light flashingPotterton Assure Heat, Titanium Heat and Ultra Heat have no display: the illuminated button flashes red a number of times when the boiler has locked out. The count is the code.Get it checked
E15The Assure and Promax Ultra's own-valve code: the board has detected a fault in the gas valve itself, not its cable. One reset allowed; then an engineer with a meter.Get it checked
E384The Assure and Promax Ultra report a flame signal while the gas valve is shut. An electrode or PCB fault, and the Assure manual's answer is to go over the board.Get it checked
E270Circulation fault (dry fire) on the Potterton Assure and Promax Ultra: the burner lit with too little water passing the heat exchanger. Not resettable by the owner; engineer.Get it checked
E83Communication error on the Potterton Assure and Promax Ultra: the board has lost contact with a connected control such as an OpenTherm room unit. Check the control and its wiring first.Usually simple to fix
E134The Promax Ultra's timed-out ignition: the gas valve was held open for the whole ignition period and nothing arrived to light. Check the supply, reset once, then call.Get it checked
E154Flow/return sensor temperature test on the Potterton Assure and Promax Ultra: the two heating sensors disagree with each other or with physics. Usually circulation; sometimes a sensor.Get it checked
E321Hot water NTC fault on the Potterton Assure Combi and Promax Ultra — the digital-display successor to E50. Shown with a spanner; hot water stops, engineer needed.Get it checked
E40Central heating return NTC fault on the Potterton Assure and Promax Ultra. The return sensor is open or short. Shown with a spanner; engineer.Get it checked
E103Codes 103, 104, 107 and the word "Bat" on the Potterton Assure: the user guide names them only to say contact your installer or Baxi Customer Support. They concern the safety board's battery.Get it checked
E55Calibration required on the Potterton Promax Ultra — shown after the gas valve or board is replaced until the engineer runs the calibration routine. Not a fault an owner will meet unprompted.Usually simple to fix
E131Interruption of power supply while in fault mode — the Potterton Promax Store only. The power went off while another code was showing. Restore power, read the code that follows.Usually simple to fix