Worcester Bosch boiler fault codes

Worcester Bosch publish their fault codes to the trade, not to owners. There is no householder code table on their website; the codes live in the installation and servicing instructions written for each range, and that is where these pages are read from. It also explains the confusion around Worcester codes: the same fault is written three different ways depending on how old the boiler is — four, counting the boilers from before the Greenstar name, which have no display at all and flash their indicator lights instead. A Greenstar i or Compact shows a letter pair such as EA with a three-digit number such as 227 beneath it, and both halves matter. A CDi Classic shows only the letters. A Greenstar 8000 Life shows only the number. Quoting half a code is why so many Worcester diagnoses go round in circles — EA 227 and EA 229 are different faults with different fixes.

Where the code shows on a Worcester Bosch

Work out which display you have before you look anything up, because it decides what the characters mean. Five generations are in UK homes. The Greenstar CDi Classic and its Heatronic 3 relatives — the earlier CDi combi, system and regular boilers, the Highflow CDi and the FS CDi — have a small display that normally shows the flow temperature and, in a fault, two characters only: EA, E9, A1, b1, Fd. There is no number. The Greenstar i and i System from 2015, and the CDi Compact, Si Compact and 27i/30i System Compact from 2014, show the two characters with a three-digit cause code beneath them, and Worcester's user guide asks you to quote both, their example being "EA and 227". During a lockout the number flashes on the display; during a blocking pause it is only visible in the info menu. The Greenstar 8000 Life, 8000 Style and 8000+, the 4000 and the 2000 have a text display and give a plain number — 224, 227, 1017, 2951 — alongside a description, with no letters at all. Worcester sort those numbers into categories: operating messages in the 200s that are not faults, blocking faults the boiler clears itself, locking faults that need the keys, and maintenance codes in the 1000s that leave it running. On the 2000 a fault shows with an H symbol, and on the 8000 Life the display alternates LoPr with the reading when the pressure has dropped out. And the Greenstar 24i and 28i Junior, the 25Si and 30Si, the Ri and the Ri Compact have no display. On those the blue light is the code, and Worcester do publish its meaning, in the installation instructions rather than the user guide: a slow flash that is mostly off with the reset button flashing is an ignition lockout; a slow flash that is mostly on is a flue or heat exchanger overheat; a fast flash with the reset button dark is a sensor, fan or code plug fault; a fast flash with the reset button flashing is an internal fault; and two or five pulses mean an engineer has left the boiler in its minimum or maximum service mode. The 27Ri and 30Ri Compact from 2015 are the exception even here: their light counts one to five flashes after a five-second gap, in three groups told apart by where a burst of four fast flashes falls, and the fifteen meanings are on the blue light page. A steady blue light is a boiler switched on and healthy. Count the pattern before you ring anyone. Older still are the Worcesters from before the Greenstar name — the 24CDi, 28CDi and 35CDi II, the 26CDi Xtra, the 25Si and 28Si, the 24i and 28i Junior, the Si II, the CBi and the floor-standing Highflow 400 Electronic — which have indicator lights, mostly red, and no display: a light flashing slowly is a lockout you may reset once, a light flashing fast is a fault the boiler waits out or an engineer clears, and the red light page gives the decode Worcester print in each user guide. The 2004 to 2007 Greenstar HE range, the R 25 and 30 HE combi, R 28 HE system and 30, 35 and 40 HE Plus, is the odd one out: it has the two-character display of the CDi Classic and shares its table. Two things these pages do not cover. Worcester's oil-fired boilers — the Greenstar Heatslave II combi, whose display uses the same letter-pair-and-number system and adds burner codes such as 9F 855, and the Danesmoor, Camray and earlier Heatslave, which have a lockout light rather than codes — are serviced by OFTEC registered technicians rather than Gas Safe engineers, and oil work is not restricted by law the way gas work is. The Heatslave II's own codes are written up here with that trade named on each page: 9F 855, the burner lock-out, and 9F 856 after four resets; E9 210, the flue gas, air pressure and tank thermostat trip; A0 809, the thermal store sensor; E2 233 and 9A 360, the code plug; and H27 and H29, the two advisories. The codes it shares with the gas Greenstar i — E5 218, E9 219, E2 222 and the F0 electronics numbers — mean the same thing on the Heatslave, but those pages are written for gas boilers and name a Gas Safe engineer; for the Heatslave the person to call is an OFTEC registered technician. The Danesmoor, Camray and earlier Heatslave have no codes to write up. Nor are the letterless status numbers an engineer reads in the info menu.

How to reset a Worcester Bosch

Worcester publish a different reset for each generation, and they are not interchangeable. Greenstar CDi Classic and the other two-character displays: press the reset button for three seconds; the button and the blue fault indicator stop flashing when it has taken. The same user guide says five seconds after thawing a frozen condensate pipe, so anything from three to five is what Worcester mean. Greenstar i, i System, CDi Compact, Si Compact and i System Compact: there is a dedicated reset button, and you press it briefly once — the word Reset and a tick appear, and if it worked the boiler returns to normal. Do not press the blue light; on the Greenstar i it is an indicator, not a button. Greenstar 8000 Life, 8000 Style, 8000+, 4000 and 2000: there is no reset button. Press the up and down arrow keys together — the 8000 Life user guide says until the fault disappears, the 8000+ and 4000 guides until Reset is displayed, the 2000 manual until the H and warning symbols disappear, or switch its power off and on — and the boiler restarts and shows the current flow temperature. On the 8000+, 4000 and 2000 there is a limit: five locking-fault resets inside fifteen minutes puts the boiler into the 2980 super lock-out, which only an engineer can clear. Greenstar 24i/28i Junior and 25Si/30Si without a display: press the reset button for approximately five seconds, until it stops being lit. Greenstar Ri and Ri Compact: there is no button at all — turn the central heating temperature knob fully anticlockwise to its RESET position, hold it there for about five seconds, then turn it back to where it was. Two things on these boilers wipe settings rather than clear faults, and both are engineer procedures worth knowing about so you do not stumble into them. On a Greenstar i, holding the spanner and OK keys for about eight seconds opens the appliance menu, from which a further press returns every boiler setting and weather sensor setting to factory defaults. On an 8000 Life, service function 4-F1 in the engineer menu — reached by holding the heating and hot water keys together — resets the appliance to its basic settings and discards the installer's commissioning values. On the i Junior, holding the service and eco buttons for about seven seconds until every button flashes resets the control board itself. The pre-Greenstar boilers have their own: on the 24CDi, 28CDi, 35CDi II, 26CDi Xtra, 25Si and 28Si, and on the 24i and 28i Junior and Si II, press the reset button — on the Junior it is the fault light itself — for five seconds if a light is flashing slowly, and switch the power off and on at the socket if it is flashing fast; on the CBi and the Highflow 400 Electronic there is no button, and the heating temperature knob turned fully anticlockwise and back is the reset; on the 24i and 28i RSF a lockout is cleared by ending the demand. The Greenstar HE of 2004 to 2007 is held until the display shows two dashes. Whatever the range, Worcester say some codes cannot be cleared by a simple reset because of the internal safety systems, and their instruction is then to call them rather than keep trying. Stop after two attempts on any ignition code, stop immediately on any smell of gas or fumes, and for anything involving the gas valve, the flue or combustion the fix is a Gas Safe registered engineer's, not yours.

Most common Worcester Bosch faults

The Worcester Bosch codes people look up most.

Every Worcester Bosch fault code

54 published codes. Filtering happens in the page — every one is in the HTML.

Showing 54 of 54 codes

Every published Worcester Bosch fault code with its meaning and severity
CodeWhat it meansSeverity
EA 227The boiler tried to light and never detected a flame, so it has shut the gas off and locked out. This is the most common Worcester fault code.Stop — call an engineer
CE 207System water pressure has dropped too low for the boiler to run safely. Topping the system back up to 1.2 bar usually clears it in five minutes.Get it checked
E9 219The boiler has overheated and the safety thermostat has tripped. Water is not carrying heat away from the exchanger, and it should not be run until that is fixed.Stop — call an engineer
C6 224The fan is not reaching the speed the boiler asked for, so combustion cannot be confirmed as safe and the burner has been prevented from firing.Get it checked
EA 229The burner lit and then the flame was lost during operation. That is a different fault from failing to light in the first place.Get it checked
H07A maintenance warning, not a lockout. The boiler is still running but water pressure has fallen far enough to limit how well it heats.Get it checked
E9 224One of the two safety thermostats has tripped: the flue overheat thermostat or the high-limit stat on the heat exchanger. Worcester's own check list includes the burner gasket for flue gas leakage.Stop — call an engineer
A1 229The boiler has detected a dry-fire condition — it is trying to heat water that is not moving. Turn it off and leave it off until an engineer has seen it.Stop — call an engineer
Blue light flashingOn a Greenstar with no display, the blue light is the fault code. Steady means healthy; a flashing pattern, read with the reset button, is a diagnosis Worcester publish in the installation instructions.Get it checked
F0The boiler has found a fault inside its own electronics and stopped. F0 covers the control board and the burner control unit, and it needs an engineer.Get it checked
E5 218The flow temperature sensor has measured water leaving the heat exchanger far hotter than it should be. The boiler shut down to protect itself, and heat is not being carried away fast enough.Get it checked
A7The hot water temperature sensor has failed. Heating usually carries on as normal while the hot water runs cold, scalding, or swings between the two.Get it checked
C7The fan is not running at all, as distinct from running at the wrong speed. The burner is locked out until it is fixed.Get it checked
F7 228A flame is being detected before the burner has started. Switch the appliance off and get a Gas Safe engineer rather than resetting.Stop — call an engineer
FA 306The boiler detected a flame after it had closed the gas valve. That points to a valve letting gas past when it should be shut, and it must not be reset.Stop — call an engineer
Red light flashingOn a Worcester built before the Greenstar era, the flashing lights are the fault code. Slow means a lockout you can reset once; fast means a fault the boiler is waiting out or an engineer's.Get it checked
D5The condensate pump has failed or cannot discharge. Acidic water will back up inside the appliance, so it needs attention promptly.Get it checked
2951The flame has been lost too many times in a row and the boiler has locked out. Each loss was a 229; Worcester's instruction is to read the history and find what put it out.Stop — call an engineer
E2 222The flow temperature sensor is giving a reading the appliance cannot trust. Usually the sensor rather than the temperature.Get it checked
C1 264Airflow stopped part way through a firing cycle. The fan has quit or the flue is obstructed, and combustion gases may not be leaving safely.Get it checked
A8The boiler has lost communication with a Worcester control on the two-wire bus — a Sense, FX or FW controller, or a Wave thermostat. Heating usually carries on at the boiler's own settings.Get it checked
D1 240The return temperature sensor has short circuited. The boiler has lost its reading of how warm the water is when it comes back from the radiators.Get it checked
9U 233The heat control module is loose, missing or faulty. This small plug-in part carries the identity of your boiler, and nothing runs without it.Get it checked
9F 855The oil burner could not establish or keep a flame and its control box has locked out. Worcester allow a reset and an oil-level check; four lockouts in one demand become 9F 856.Get it checked
2910Fault in flue system. The boiler has detected a problem with its flue and locked out. Worcester's checks are obstructions, the flue integrity test and water in the sump. Not a code to reset repeatedly.Stop — call an engineer
Fd 231Power to the boiler was cut while it sat in a lockout, so a fault happened before the interruption. On older Greenstars, Fd simply means the reset button was pressed by mistake.Get it checked
1065The system pressure sensor is faulty or not connected. The boiler cannot read its own water pressure, so it stops rather than guess. Worcester check the plug, the harness, the voltage, then the sensor.Get it checked
EA 261An ignition fault that Worcester define two ways: on the Greenstar i it points at the heat control module, on the Compact range it means the flame was not established inside the four-second ignition window.Stop — call an engineer
D4 341The water temperature in the boiler is climbing faster than it should, which means very little of it is moving. Worcester's checks are pressure, air, circulation and the pump, in that order.Get it checked
2980Super lock-out. Five locking faults were reset inside fifteen minutes while the boiler saw a potentially safety-critical condition, so it has locked itself against further resets. Only an engineer can clear it.Stop — call an engineer
b1The control board cannot find its code plug, the small module that tells it which boiler it is fitted to. Without it the board will not run. Usually follows a board or plug being disturbed.Get it checked
H03Planned maintenance required. The Greenstar i is saying a service interval has passed — H03 counts burner hours, H08 a set date, H13 a number of months. A reminder, not a fault.Usually simple to fix
9F 856Four 9F 855 burner lock-outs have been reset in one demand, so the controls have locked the reset out to protect the burner. A power-down clears the count; the cause is still there.Get it checked
C4 273The fan has run continuously for 24 hours, so the boiler has paused firing for two minutes as a precaution. Something has been calling for heat non-stop, and that is what to find.Usually simple to fix
SESE alternating with the temperature on a CDi Classic is a service reminder, not a fault. The burner has run the hours Worcester equate to a year, and the boiler wants its annual check.Usually simple to fix
2970The heating system's pressure has dropped too quickly too often. On an 8000 with the intelligent filling loop this usually follows venting after an automatic fill; otherwise it is a leak that needs finding.Get it checked
E9 210One of three manual-reset safety devices has opened: the flue gas overheat thermostat, the air pressure switch or the tank overheat thermostat. Overheated flue gases or a restricted flue are the usual reasons.Stop — call an engineer
EA 234The control board cannot see the gas valve coil, so it will not attempt to light. Worcester call it a gas valve error, coil disconnected. No gas is released, but it is a gas job.Get it checked
E9 220The safety temperature sensor on the heat exchanger has failed electrically — 220 is a short circuit, 221 an open circuit. Nothing is overheating; the boiler has stopped because it can no longer prove that.Get it checked
2948The burner lit but the flame signal was not there at low output. The boiler purges and tries again itself; Worcester's checks are the CO2 setting, the flue and the terminal, and they mention wind.Get it checked
D1 286The return water coming back into the boiler is too hot, and the boiler has locked out on overheat at the return sensor rather than the flow. Worcester describe it simply as boiler overheat.Get it checked
Fb 365The gas valve failed its own leak test. Worcester publish Fb 365 for the first valve seat and FA 364 for the second; both mean gas may pass a valve that should be shut.Stop — call an engineer
H09The control board has lost its data link to the pump. The boiler keeps running, but Worcester flag it because a pump the board cannot talk to is either wired wrongly or the wrong pump.Get it checked
A0 809The sensor reading the Heatslave II's internal hot water store has failed or lost its connection, so the boiler cannot tell how hot the store is and locks out until it is checked or replaced.Get it checked
A6The boiler thinks an external limit thermostat has opened — usually the underfloor heating stat — or the link that stands in for one is missing. Nothing runs until that circuit is closed again.Get it checked
EF 349The boiler is on its lowest flame and the water is still leaving far hotter than it returns — more than 18 °C hotter. Worcester call it boil detect, and it means circulation has collapsed.Get it checked
CCThe outdoor temperature sensor for weather compensation is not being read — open circuit, short circuit or disconnected. The boiler keeps heating but loses its weather-adjusted control.Usually simple to fix
F1An internal data error in the control board — Worcester call it a ROM error on the Highflow. The board's own memory check has failed and the remedy is the board itself.Get it checked
b7 257An internal error in the burner control. Worcester's remedy is the control board, after checking the heat control module is seated. There is nothing to try beyond one reset.Get it checked
E2 233The heat control module, the code plug that tells the board which Heatslave II it is running, is missing, loose or faulty. 9A 360 is its sibling: a plug fitted for the wrong boiler.Get it checked
2945Too many short heat demands in a short time. The Greenstar 2000 has locked out because it kept being asked to fire and stop — usually a system with nowhere for the heat to go.Get it checked
2911Calibration failed. The Greenstar 2000 sets its own combustion by reading the flame, and the reading did not add up. Worcester check the electrode, its earth, the siphon, then the gas valve or board.Get it checked
A5The cylinder or heat bank temperature sensor has failed — open or short circuit. Heating carries on; the boiler just no longer knows how hot the stored water is, so hot water control suffers.Usually simple to fix
H27A warning triangle with H27 means the sensor on the incoming cold mains has failed. Worcester say operation is not affected, so heating and hot water carry on until the sensor is replaced.Usually simple to fix