Skip to content
FaultcodeCheck

Worcester Bosch E9 220 fault codewhat it means and how to fix it

Get it checkedBoilerGreenstar CDi Compact, Si Compact and 27i/30i System Compact ErP, where E9 is shown with 220 or 221 beneath it. The Greenstar i ErP table does not publish these cause codes, and the CDi Classic display shows E9 alone. Greenstar 8000 Life, 8000 Style, 8000+, 4000 and 2000 show the heat exchanger sensor as 1075 (short circuit) and 1076 (disconnected), maintenance codes, and 2963 when the heat exchanger sensor or both it and the flow sensor read as defective.Last updated

The safety temperature sensor on the heat exchanger has failed electrically — 220 is a short circuit, 221 an open circuit. Nothing is overheating; the boiler has stopped because it can no longer prove that.

Take care

Some of this is safe to check yourself, but the repair itself is not. If the fault comes back after one reset, stop resetting it and get a Gas Safe registered engineer to look at the Worcester Bosch properly.

Get a Gas Safe registered engineer to look at your Worcester Bosch E9 220

We do not pass enquiries to a repair firm, so there is no form here. Find a Gas Safe registered engineer through the Gas Safe Register, and ask to see their registration card when they arrive — it is the register, not the van, that tells you they are qualified.

What E9 220 means

The Compact family carries a dedicated safety sensor on the main heat exchanger, separate from the flow sensor, and E9 219 is that sensor reporting a genuine overheat. E9 220 and E9 221 are the same sensor failing to report at all.

Worcester's table reads "E9 220 — safety sensor short circuit — maximum temperature sensor on the main heat exchanger has failed" and "E9 221 — safety sensor open circuit — maximum temperature sensor on the main heat exchanger has not been recognised". Both are locking errors cleared with the reset button, and both stop the boiler for the same reason: the control will not run a burner whose safety limit it cannot measure. So the temperature that matters here is not high. What has happened is that a thermistor has gone to a resistance the board treats as impossible, either near zero — a short, often water in the connector — or effectively infinite, meaning the sensor or its lead is disconnected.

The remedy in the D1 return-sensor rows of the same table is a fair guide to what the engineer does: check the harness and connector, test the sensor against the published resistance curve, replace as needed. The Greenstar i table publishes E2 350 and E2 351 for the equivalent short and open circuit on the flow sensor but does not list 220 or 221, and the CDi Classic display shows E9 alone for any safety-circuit fault, so which range you have decides whether these numbers can appear.

What causes it

Causes of the Worcester Bosch E9 220 fault code, most common first
CauseWhat is actually happeningHow likely
Water in the sensor connectorA weeping joint above the heat exchanger drips onto the sensor plug, and a wet connector reads as a short circuit and gives 220.Common
Sensor lead disconnected or brokenA plug knocked off during a service, or a lead chafed through where it passes the casing, reads as open circuit and gives 221.Common
Failed thermistorThe sensor element itself drifts out of range with age and heat cycling. It is a cheap part, confirmed by comparing its resistance with Worcester's table.Occasional
Control board input faultIf the sensor and lead test correctly at the plug and the fault remains, the board's sensor input has failed and the board is replaced.Rare

Can you fix it yourself?

What it costs to fix

Typical repair cost

£90–£200

Time on site

40 minutes

Sensor or connector £90–£160 fitted. If a leak has caused it, add the cost of the leak repair.

Typical UK prices including parts and labour, updated September 2026. Your quote may differ.

Parts you may need

We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.

Worcester Bosch Greenstar flow temperature sensor (flow NTC)

87145000870£15–£40Authorised Worcester parts distributor

Price checked 28 September 2026

Worcester Bosch Greenstar control board (PCB)

£250–£450Authorised Worcester parts distributor

Price checked 28 September 2026

Own this appliance and had this code? . Nothing is published until a person has read it.

Common questions about Worcester Bosch E9 220

Is 220 more serious than 221?

No. They are the two ways the same sensor can fail — shorted or disconnected — and the fix is the same. Worcester list both as locking errors with the reset button. Quote whichever you see.

Why does the boiler stop if nothing is too hot?

Because it cannot tell. The safety sensor is the board's proof that the heat exchanger is within limits, and a boiler that lost that proof and kept firing would be running blind. Stopping is the correct response.

Is this the same as E9 219?

Same sensor, different message. 219 is the sensor working and reading too high — a real overheat with real causes in the pump and system. 220 and 221 are the sensor not working at all.

Written by

Andrew Pickett

Researcher and writer

Last updated

Technical review

Not reviewed by an engineer

No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.

What we check instead

Sources and how we verified this

We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.

  • Manufacturer technical and service documentation

This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.

Read our full verification process

Was this page helpful?