Worcester Bosch C6 224 fault codewhat it means and how to fix it
The fan is not reaching the speed the boiler asked for, so combustion cannot be confirmed as safe and the burner has been prevented from firing.
Take care
What can you hear at startup?
The right answer depends on what you can see. Pick the one that matches.
Choose the option on the left that matches what your appliance is doing, and the answer for that case appears here.
No fan noise at all
The fan is not turning — seized, or not receiving power from the board.
Book an engineer. Worcester fans are stocked parts and usually a single visit.
Grinding or droning, then lockout
Worn bearings. The fan turns but cannot hold commanded speed.
Straightforward fan replacement.
There is visibly something in or against the flue terminal
A restricted flue stops the fan reaching speed and, more importantly, stops combustion products clearing properly.
Do not run the boiler and do not clear it yourself. This needs a Gas Safe registered engineer who will check the whole flue run.
What C6 224 means
The fan on a condensing boiler both supplies combustion air and clears flue gases, and the control board monitors its actual speed against the commanded speed on every cycle. C6 224 means the two do not agree. The boiler will not fire when it cannot verify that flue products are being removed, which is exactly the behaviour you want. The usual physical cause is a fan reaching the end of its service life, and it normally warns you first with weeks of rattling or droning on startup. The alternative cause — a restricted flue or air intake — produces an identical reading and carries a genuine combustion risk, which is why the flue is always checked as part of diagnosing this code.
What causes it
| Cause | What is actually happening | How likely |
|---|---|---|
| Worn fan bearings | Most common past eight to ten years. Usually preceded by a rattle or drone. | Common |
| Obstructed flue terminal | Nesting birds in spring, leaves, or a new structure built too close to the terminal. | Occasional |
| Failed fan speed sensor or wiring | The fan spins correctly but the board cannot read the speed signal. | Occasional |
| Control board fault | The board is not driving the fan correctly. Diagnosed by elimination. | Rare |
What to try yourself
Look at the flue terminal outside. Check for nests, leaves, or anything built near it since the boiler last worked — a new fence panel or shed roof is enough.
Look only. Never push anything into a flue terminal; you risk driving a clearable obstruction deeper into the flue.Listen at startup. Rattling, droning or grinding before the lockout means worn bearings, and telling the engineer that saves them diagnostic time.
Reset once. If it returns within a cycle or two, leave it and book someone.
Get a Gas Safe registered engineer to look at your Worcester Bosch C6 224
Gas Safe Register engineers only. No obligation.
What it costs to fix
Typical repair cost
£240–£400
Time on site
1h 30m
Fan replacement £240–£400 fitted. Flue terminal clearance £90–£180.
Typical UK prices including parts and labour, updated August 2026. Your quote may differ.
Parts you may need
We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.
Worcester Bosch Greenstar fan assembly
87161431070£130–£250Authorised Worcester parts distributor
Price checked 5 August 2026
What other owners found
Nobody has shared what worked for them on this code yet. If you have had it, you would be the first — and it genuinely helps the next person.
Related Worcester Bosch fault codes
- C7Get it checkedThe fan is not running at all, as distinct from running at the wrong speed. The burner is locked out until it is fixed.Related: fan and flue
- D5Get it checkedThe condensate pump has failed or cannot discharge. Acidic water will back up inside the appliance, so it needs attention promptly.Related: fan and flue
- E16Get it checkedThe control board cannot confirm the fan is running at the speed it asked for, so it will not let the burner light. This one needs an engineer.Related: fan and flue
- F.32Get it checkedThe fan is not running at the speed the boiler expects, so combustion cannot be verified as safe and the boiler has locked out.Related: fan and flue
- E160Get it checkedThe fan is not running at the speed the appliance expects. Baxi direct engineers to check the fan and its cable, in that order.Related: fan and flue
- F3Get it checkedThe fan is not running at the speed the boiler expects, so it cannot confirm the flue is clearing and has stopped the burner firing.Related: fan and flue
Related guides
Common questions about Worcester Bosch C6 224
How long should a Worcester fan last?
Ten to fifteen years typically. They rarely fail without warning — months of noise on startup is a bearing wearing out, and replacing it before it strands you costs the same as an emergency call-out but at a time you choose.
What does the repair cost?
Fan replacement is usually £240 to £400 fitted. Clearing an obstructed terminal is £90 to £180. If the board is at fault, £320 to £520.
Can I run the boiler until the part arrives?
You will not be able to — the boiler prevents the burner firing when it cannot verify the fan. That refusal is a safety interlock and it is not something to try to work around.