Worcester Bosch C7 fault codewhat it means and how to fix it

Get it checkedBoilerGreenstar i and i System ErP and the CDi Compact, Si Compact and 27i/30i System Compact, where C7 is shown with 214 beneath it if the fan did not run at start-up and 217 if the airflow was lost after a set period. Not published for the CDi Classic, whose fan fault is C6. Greenstar 8000 Life, 8000 Style, 8000+, 4000 and 2000 show the fan faults as plain numbers: 214, fan shut down during safety time; 2961 and 2962, no fan signal available or fan not running; and on the 2000, 215 for a fan too fast.Last updated

The fan is not running at all, as distinct from running at the wrong speed. The burner is locked out until it is fixed.

Take care

Some of this is safe to check yourself, but the repair itself is not. If the fault comes back after one reset, stop resetting it and get a Gas Safe registered engineer to look at the Worcester Bosch properly.

Get a Gas Safe registered engineer to look at your Worcester Bosch C7

We do not pass enquiries to a repair firm, so there is no form here. Find a Gas Safe registered engineer through the Gas Safe Register, and ask to see their registration card when they arrive — it is the register, not the van, that tells you they are qualified.

What C7 means

Worcester separate two fan conditions and it is worth knowing which you have. C6 means the fan speed is wrong — too low, or on some models too high. C7 means the fan is not running. That distinction narrows the diagnosis usefully: a fan turning at the wrong speed is usually a worn fan or a flue restriction changing its loading, whereas a fan not turning at all is more often electrical — a failed motor, a lost supply, or a broken connection.

The interlock behind both is the same and it is absolute. No condensing appliance will open its gas valve without proof that the fan is clearing combustion products through the flue, and there is no way to run around that. What a householder can usefully contribute is history: whether the appliance has been getting noisier over recent months, and whether anything obvious is blocking the flue terminal when viewed from the ground.

What causes it

Causes of the Worcester Bosch C7 fault code, most common first
CauseWhat is actually happeningHow likely
Fan motor failedThe most direct explanation for a fan that is not turning. Often the end point of months of increasing start-up noise.Common
Fan seized mechanicallyBearings that have finally bound up rather than merely worn. Sometimes accompanied by a brief hum as the appliance tries to start it.Common
Wiring or connector failureNo supply reaching the fan, or a broken connection in the harness. Considerably cheaper than a fan and worth eliminating first.Occasional
Control board not driving the fanThe board is failing to energise it. Diagnosed once the fan and its wiring have been proved.Occasional

Can you fix it yourself?

What it costs to fix

Typical repair cost

£200–£450

A replacement fan is typically £300 to £450 fitted on the Greenstar range. A wiring repair is a call-out charge of £80 to £150.

Typical UK prices including parts and labour, updated September 2026. Your quote may differ.

Parts you may need

We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.

Worcester Bosch Greenstar fan assembly

87161431070£130–£250Authorised Worcester parts distributor

Price checked 28 September 2026

Own this appliance and had this code? . Nothing is published until a person has read it.

Common questions about Worcester Bosch C7

What is the difference between C6 and C7?

C6 means the fan speed is wrong; C7 means the fan is not running. C6 more often turns out to be a worn fan or a flue restriction, while C7 skews towards an electrical failure. Quote whichever number you can actually see, because it changes where the engineer starts.

The boiler was grinding for months before this. Related?

Almost certainly. A fan bearing that grumbles on start-up and quietens as it spins up is wearing out, and a seizure is where that ends. Reporting that noise early turns an emergency into a planned repair.

Can I get heating any other way in the meantime?

Not from the boiler — the fan interlock blocks every burner operation including hot water. A plug-in electric heater for a day is the practical answer.

Written by

Andrew Pickett

Researcher and writer

Last updated

Technical review

Not reviewed by an engineer

No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.

What we check instead

Sources and how we verified this

We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.

  • Manufacturer technical and service documentation

This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.

Read our full verification process

Was this page helpful?