Worcester Bosch D5 fault codewhat it means and how to fix it
The condensate pump has failed or cannot discharge. Acidic water will back up inside the appliance, so it needs attention promptly.
Take care
What D5 means
Not every boiler has a condensate pump, but a good many Worcester installations do — wherever the appliance sits below the drain it has to discharge into, such as a basement, a converted loft, or a kitchen where the only available drain is on the far side of the room. In those cases a small electric pump lifts the condensate to where gravity can take over. D5 means that pump has failed or cannot discharge. This matters more than it might sound. A condensing boiler produces a surprising volume of water — several litres a day in cold weather — and it is mildly acidic, typically around pH 3 to 4. With nowhere to go it backs up into the appliance and eventually into the room. The appliance shuts down to limit the damage, which is the correct behaviour. Because a condensate pump is often an add-on fitted alongside the boiler rather than part of it, it is also the component most likely to be forgotten at service time.
What causes it
| Cause | What is actually happening | How likely |
|---|---|---|
| Pump failed electrically | These are small, inexpensive units running several cycles an hour for years. They wear out, and they usually do so without warning. | Common |
| Pump reservoir silted or scaled | The reservoir accumulates deposit over years, and eventually the float switch stops moving freely or the outlet restricts. | Common |
| Discharge pipe blocked or frozen | Where the pump discharges to an external drain, the same freezing that affects gravity condensate runs affects this one. The pump then runs against a blockage and reports a fault. | Occasional |
| Power supply to the pump lost | A tripped spur or a disconnected plug. Worth checking because it costs nothing, and these pumps are sometimes on a separate supply from the boiler. | Occasional |
What to try yourself
Find the condensate pump. It is a small plastic box, usually white or grey, sitting below or beside the appliance with a thin discharge pipe leaving it.
Check whether it has power. Some are plugged into a socket or fed from their own fused spur, and a tripped switch is a free fix.
Look for standing water in or around the unit, and check whether the floor beneath is wet. If water has escaped, mop it up and put a towel down — it is mildly acidic and will mark flooring over time.
Do not dismantle the pump or the appliance. Condensate is acidic enough to irritate skin and eyes; if you get any on you, rinse it off.In cold weather, check where the discharge pipe ends outside for ice, and thaw it with hand-hot water as you would a normal condensate run.
If none of that resolves it, book an engineer. A replacement condensate pump is one of the cheaper repairs on a boiler and it is not worth living with.
Get a Gas Safe registered engineer to look at your Worcester Bosch D5
Gas Safe Register engineers only. No obligation.
What it costs to fix
Typical repair cost
£140–£320
Time on site
20 minutes
A replacement condensate pump is typically £160 to £300 fitted. Clearing a frozen or blocked discharge line is a call-out charge of £80 to £150.
Typical UK prices including parts and labour, updated August 2026. Your quote may differ.
Parts you may need
We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.
Condensate trap and siphon
COND-TRAP£15–£38Plumbing merchant
Price checked 5 August 2026
What other owners found
Nobody has shared what worked for them on this code yet. If you have had it, you would be the first — and it genuinely helps the next person.
Related Worcester Bosch fault codes
- C6 224Get it checkedThe fan is not reaching the speed the boiler asked for, so combustion cannot be confirmed as safe and the burner has been prevented from firing.Related: fan and flue
- C7Get it checkedThe fan is not running at all, as distinct from running at the wrong speed. The burner is locked out until it is fixed.Related: fan and flue
- E16Get it checkedThe control board cannot confirm the fan is running at the speed it asked for, so it will not let the burner light. This one needs an engineer.Related: fan and flue
- F.32Get it checkedThe fan is not running at the speed the boiler expects, so combustion cannot be verified as safe and the boiler has locked out.Related: fan and flue
- E160Get it checkedThe fan is not running at the speed the appliance expects. Baxi direct engineers to check the fan and its cable, in that order.Related: fan and flue
- F3Get it checkedThe fan is not running at the speed the boiler expects, so it cannot confirm the flue is clearing and has stopped the burner firing.Related: fan and flue