Worcester Bosch D5 fault codewhat it means and how to fix it

Get it checkedBoilerGreenstar models fitted with a condensate pumpLast reviewed

The condensate pump has failed or cannot discharge. Acidic water will back up inside the appliance, so it needs attention promptly.

Take care

Some of this is safe to check yourself, but the repair itself is not. If the fault comes back after one reset, stop resetting it and get a Gas Safe registered engineer to look at the Worcester Bosch properly.

What D5 means

Not every boiler has a condensate pump, but a good many Worcester installations do — wherever the appliance sits below the drain it has to discharge into, such as a basement, a converted loft, or a kitchen where the only available drain is on the far side of the room. In those cases a small electric pump lifts the condensate to where gravity can take over. D5 means that pump has failed or cannot discharge. This matters more than it might sound. A condensing boiler produces a surprising volume of water — several litres a day in cold weather — and it is mildly acidic, typically around pH 3 to 4. With nowhere to go it backs up into the appliance and eventually into the room. The appliance shuts down to limit the damage, which is the correct behaviour. Because a condensate pump is often an add-on fitted alongside the boiler rather than part of it, it is also the component most likely to be forgotten at service time.

What causes it

Causes of the Worcester Bosch D5 fault code, most common first
CauseWhat is actually happeningHow likely
Pump failed electricallyThese are small, inexpensive units running several cycles an hour for years. They wear out, and they usually do so without warning.Common
Pump reservoir silted or scaledThe reservoir accumulates deposit over years, and eventually the float switch stops moving freely or the outlet restricts.Common
Discharge pipe blocked or frozenWhere the pump discharges to an external drain, the same freezing that affects gravity condensate runs affects this one. The pump then runs against a blockage and reports a fault.Occasional
Power supply to the pump lostA tripped spur or a disconnected plug. Worth checking because it costs nothing, and these pumps are sometimes on a separate supply from the boiler.Occasional

What to try yourself

  1. Find the condensate pump. It is a small plastic box, usually white or grey, sitting below or beside the appliance with a thin discharge pipe leaving it.

  2. Check whether it has power. Some are plugged into a socket or fed from their own fused spur, and a tripped switch is a free fix.

  3. Look for standing water in or around the unit, and check whether the floor beneath is wet. If water has escaped, mop it up and put a towel down — it is mildly acidic and will mark flooring over time.

    Do not dismantle the pump or the appliance. Condensate is acidic enough to irritate skin and eyes; if you get any on you, rinse it off.
  4. In cold weather, check where the discharge pipe ends outside for ice, and thaw it with hand-hot water as you would a normal condensate run.

  5. If none of that resolves it, book an engineer. A replacement condensate pump is one of the cheaper repairs on a boiler and it is not worth living with.

Get a Gas Safe registered engineer to look at your Worcester Bosch D5

Gas Safe Register engineers only. No obligation.

What it costs to fix

Typical repair cost

£140–£320

Time on site

20 minutes

A replacement condensate pump is typically £160 to £300 fitted. Clearing a frozen or blocked discharge line is a call-out charge of £80 to £150.

Typical UK prices including parts and labour, updated August 2026. Your quote may differ.

Parts you may need

We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.

Condensate trap and siphon

COND-TRAP£15–£38Plumbing merchant

Price checked 5 August 2026

What other owners found

Nobody has shared what worked for them on this code yet. If you have had it, you would be the first — and it genuinely helps the next person.

Written by

Fault Code Check editorial team

Updated

Reviewed by

Technical reviewer

Gas Safe registration to be displayed on appointment

Last reviewed

Sources and how we verified this

We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.

  • Manufacturer technical and service documentation
  • Interviews with working engineers

Checked by Technical reviewer (Gas Safe registration to be displayed on appointment) on 5 August 2026.

Read our full verification process