Worcester Bosch C1 264 fault codewhat it means and how to fix it

Get it checkedBoilerGreenstar i and i System ErP and the CDi Compact, Si Compact and 27i/30i System Compact, where C1 is shown with 264 beneath it: fan stopped during operation. Not published for the CDi Classic, whose only fan code is C6, fan speed too low. The Greenstar 2000 shows 264 alone as a blocking fault, air handling failed during operation, with the fan plug, the fan, mains voltage, the flue and the venturi as its checks. The 8000 Life and 4000 tables do not use 264 and file fan faults under 214, 2961 and 2962. The 2004 to 2007 Greenstar HE range shows C1 alone, fan speed too low: fan lead and connector, then the fan.Last updated

Airflow stopped part way through a firing cycle. The fan has quit or the flue is obstructed, and combustion gases may not be leaving safely.

Take care

Some of this is safe to check yourself, but the repair itself is not. If the fault comes back after one reset, stop resetting it and get a Gas Safe registered engineer to look at the Worcester Bosch properly.

Get a Gas Safe registered engineer to look at your Worcester Bosch C1 264

We do not pass enquiries to a repair firm, so there is no form here. Find a Gas Safe registered engineer through the Gas Safe Register, and ask to see their registration card when they arrive — it is the register, not the van, that tells you they are qualified.

What happened around the time it stopped?

The right answer depends on what you can see. Pick the one that matches.

Choose the option on the left that matches what your appliance is doing, and the answer for that case appears here.

A carbon monoxide alarm went off

Do not treat this as a boiler repair question. Products of combustion have reached the room, and people come first.

Everyone outside into fresh air, ring 0800 111 999, and get medical advice for anyone feeling unwell.

It runs for a few minutes then locks out every time

A repeatable failure once warm fits a fan giving up under heat or a restriction that only matters at full flow.

Leave it off and describe the timing to the engineer. It genuinely narrows the diagnosis.

There are birds or nesting around the flue outside

A partially blocked terminal is a common cause and one an engineer can confirm quickly from outside.

Do not poke anything into the flue. Mention what you have seen and let it be inspected properly.

What C1 264 means

Worcester publish this one exactly as it appears here. Their Greenstar i fault table gives C1 264 under the heading "fan/airflow fault" with the description "fan stopped during operation", and the checks they list are the fan harness and connector, 230 V ac across the brown and blue wires, and the operation of the fan itself, replacing it if necessary.

Note what is not on that list: Worcester do not attribute this code to a blocked flue, and an earlier version of this page did. The distinction that matters is the timing rather than the flue. C1 264 is reported when the boiler loses airflow during operation rather than at start-up. The fan draws air in for combustion and pushes the products out through the flue, and the boiler watches that this continues for as long as the burner is lit.

Losing it mid-cycle is treated more seriously than never establishing it, because the burner has already been running and there is a real prospect that exhaust gases were not being carried away for some part of that time. The usual causes are a fan failing under load, a loss of power or signal to it, or a flue that has become restricted. Whatever the cause, the possibility that combustion products entered the room is what drives the response: leave it off, and get it checked before it runs again.

What causes it

Causes of the Worcester Bosch C1 264 fault code, most common first
CauseWhat is actually happeningHow likely
Fan failing once warmWorn bearings often turn freely from cold and then stall as the casing heats and clearances close up.Common
Flue obstructionNesting material, debris or a collapsed liner narrows the path until the fan can no longer maintain flow.Common
Loss of power or control signal to the fanA connector that expands slightly with heat can break contact only once the appliance is up to temperature.Occasional
Condensate backing up into the flue pathA blocked trap or siphon can fill enough of the passage to disturb the airflow the boiler is monitoring.Occasional

Can you fix it yourself?

What it costs to fix

Typical repair cost

£120–£400

Fan assembly £220–£400 fitted. Flue clearance and test £120–£280, more where access is difficult. A combustion check should follow either.

Typical UK prices including parts and labour, updated September 2026. Your quote may differ.

Parts you may need

We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.

Worcester Bosch Greenstar fan assembly

87161431070£130–£250Authorised Worcester parts distributor

Price checked 28 September 2026

Condensate trap and siphon

COND-TRAP£15–£38Plumbing merchant

Price checked 28 September 2026

Own this appliance and had this code? . Nothing is published until a person has read it.

Common questions about Worcester Bosch C1 264

Is this worse than a fan fault at start-up?

Yes, and for a specific reason. If the fan never starts, the boiler refuses to light and nothing has burned. C1 264 means the burner was already alight when airflow was lost, so there is a window during which exhaust may not have been leaving properly.

Do I have a carbon monoxide problem?

Not necessarily, and the code alone cannot tell you. The boiler stopped precisely to prevent one. But because the burner was running when airflow failed, it must be treated as a possibility until an engineer has tested the flue and combustion. If you do not have a CO alarm, fit one.

How is it different from C6 and C7?

They describe the fan at other moments — running at the wrong speed, or not starting at all. C1 264 is specifically airflow ceasing during operation. Same components, different point in the cycle, and a different level of concern.

What does the repair usually come to?

A fan is £220 to £400 fitted. Clearing and testing a flue is £120 to £280, more if scaffolding or roof access is needed. Both should end with a combustion analysis to confirm the appliance is burning correctly.

Written by

Andrew Pickett

Researcher and writer

Last updated

Technical review

Not reviewed by an engineer

No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.

What we check instead

Sources and how we verified this

We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.