Worcester Bosch EA 227 fault codewhat it means and how to fix it

Stop — call an engineerBoilerGreenstar i, CDi and 8000 seriesLast reviewed

The boiler tried to light and never detected a flame, so it has shut the gas off and locked out. This is the most common Worcester fault code.

Get a Gas Safe registered engineer to look at your Worcester Bosch EA 227

Gas Safe Register engineers only. No obligation.

What is happening elsewhere in the house?

The right answer depends on what you can see. Pick the one that matches.

Choose the option on the left that matches what your appliance is doing, and the answer for that case appears here.

The gas hob will not light either

There is no gas reaching the property. The boiler is behaving correctly by locking out.

Check the emergency control valve at the meter is in line with the pipe, and check a prepayment meter for credit. If both are fine, call your supplier.

It is freezing outside and the boiler worked yesterday

A frozen condensate pipe is the most likely cause. It is the classic first-cold-snap Worcester fault.

Pour warm — not boiling — water along the external white plastic pipe, then reset. If it fires and stays lit, that was it.

You hear repeated clicking, then it stops

That clicking is the ignition sparking. Gas is reaching the ignition point but either not igniting or not being detected once lit — the electrode is the prime suspect.

Book a Gas Safe registered engineer. Do not reset more than twice while you wait.

You can smell gas

Stop immediately. Do not reset, do not operate any electrical switch, and do not try to find the leak.

Open the windows, leave the property, and call the National Gas Emergency Service on 0800 111 999 from outside.

What EA 227 means

EA 227 means no flame was sensed during the ignition sequence. The boiler opens the gas valve, sparks, and then looks for an ionisation current across the flame sensing electrode to confirm that gas is actually burning. No current means no flame, and the boiler closes the valve and locks out rather than continuing to release gas. The 227 suffix specifically identifies flame detection failure at startup, as opposed to other EA conditions. In practice the cause is usually mundane: no gas reaching the appliance, or an electrode that has carboned up and can no longer detect the flame it has successfully lit.

What causes it

Causes of the Worcester Bosch EA 227 fault code, most common first
CauseWhat is actually happeningHow likely
No gas at the applianceEmpty prepayment meter, a service valve knocked shut, or a supply interruption. Test by trying another gas appliance.Common
Dirty or worn flame sensing electrodeCarbon deposits reduce the ionisation current below the detection threshold. The boiler lights and immediately decides it has not.Common
Frozen condensate pipeIn cold weather a blocked condensate backs up and prevents the boiler completing a successful cycle.Common
Gas valve failureThe valve does not open, or opens too slowly for the ignition window.Occasional

Can you fix it yourself?

What it costs to fix

Typical repair cost

£130–£480

Time on site

1h 15m

Electrode replacement £130–£220. Gas valve £300–£480. Frozen condensate cleared free if you can reach the pipe yourself.

Typical UK prices including parts and labour, updated August 2026. Your quote may differ.

Parts you may need

We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.

Worcester Bosch Greenstar electrode set

87161431020£22–£52Authorised Worcester parts distributor

Price checked 5 August 2026

Condensate trap and siphon

COND-TRAP£15–£38Plumbing merchant

Price checked 5 August 2026

What other owners found

Nobody has shared what worked for them on this code yet. If you have had it, you would be the first — and it genuinely helps the next person.

Common questions about Worcester Bosch EA 227

What does the 227 part mean?

It is the specific condition within the EA category. EA on its own tells an engineer the boiler locked out on a flame fault; 227 tells them it was flame detection failure at ignition. Always quote both halves — it saves diagnostic time and it saves you money.

How many times can I reset it?

Twice. Each reset triggers a fresh set of ignition attempts, and each attempt releases a little gas before the valve shuts. If two resets have not fixed it, the fault is real.

Why does it happen every winter?

Because the condensate pipe freezes. Worcester boilers, like all condensing boilers, produce acidic condensate that runs out through a plastic pipe. If that pipe runs outside in 21mm plastic with a long horizontal section, the first hard frost will block it.

What will an engineer charge to fix EA 227?

If it is the electrode, £130 to £220 including the call-out and combustion check. A gas valve is £300 to £480. If it turns out to be gas supply, your supplier deals with it and it costs you nothing.

Written by

Fault Code Check editorial team

Updated

Reviewed by

Technical reviewer

Gas Safe registration to be displayed on appointment

Last reviewed

Sources and how we verified this

We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.

  • Manufacturer technical and service documentation
  • Manufacturer support portal
  • Trade body guidance

Checked by Technical reviewer (Gas Safe registration to be displayed on appointment) on 5 August 2026.

Read our full verification process