Worcester Bosch FA 306 fault codewhat it means and how to fix it

Stop — call an engineerBoilerGreenstar i and i System ErP and the CDi Compact, Si Compact and 27i/30i System Compact, where FA is shown with 306 beneath it: ionisation detected after the gas valve closed. Greenstar CDi Classic and the Heatronic 3 ranges, where FA appears alone as flame detected after gas shut off, with Worcester's coil resistances of 190 and 390 ohms printed beside it for the engineer. Greenstar 8000 Life, 8000 Style, 8000+, 4000 and 2000 show 306 alone as a locking fault, flame signal after closing the fuel supply, with the tip that the working pressure should return to standing pressure the moment the valve closes. The 2004 to 2007 Greenstar HE range shows FA alone, flame detected after gas shut off: gas valve and its wiring, clean the condensation trap, check the electrode assembly and the flue.Last updated

The boiler detected a flame after it had closed the gas valve. That points to a valve letting gas past when it should be shut, and it must not be reset.

Get a Gas Safe registered engineer to look at your Worcester Bosch FA 306

We do not pass enquiries to a repair firm, so there is no form here. Find a Gas Safe registered engineer through the Gas Safe Register, and ask to see their registration card when they arrive — it is the register, not the van, that tells you they are qualified.

What can you smell or hear?

The right answer depends on what you can see. Pick the one that matches.

Choose the option on the left that matches what your appliance is doing, and the answer for that case appears here.

You can smell gas

Treat this as an emergency and stop reading. Do not touch the boiler, any switch, or any electrical appliance.

Open windows, get everyone out, and ring the National Gas Emergency Service on 0800 111 999 from outside the property.

A carbon monoxide alarm has sounded

Combustion is happening somewhere it should not be, or products are not leaving as they should. This needs immediate action, not diagnosis.

Get everyone into fresh air, ring 0800 111 999, and seek medical advice for anyone with headache, nausea or drowsiness.

Nothing obvious — it simply locked out

Most likely the electrode or a moisture path rather than the valve, but that is a conclusion only a combustion test can reach.

Leave the boiler switched off and book a Gas Safe registered engineer. Do not reset it while you wait.

What FA 306 means

FA 306 means an ionisation current was still being measured after the burner was supposed to have stopped. In plain terms the boiler shut the gas off, looked to confirm the flame had gone out, and found it had not. There are only two explanations and both are serious. Either the gas valve is passing gas when commanded closed, or the flame detection circuit is reporting a flame that no longer exists.

The boiler cannot tell which, so it treats the situation as the more dangerous of the two and locks out hard. This is the one Worcester code where the usual advice to try a reset does not apply. If gas really is getting through a closed valve, resetting invites it to burn outside a controlled cycle, and unburnt gas or products of combustion in the wrong place is how carbon monoxide incidents begin.

What causes it

Causes of the Worcester Bosch FA 306 fault code, most common first
CauseWhat is actually happeningHow likely
Gas valve passing when closedA worn seat or debris on it lets gas seep through after the valve has been commanded shut.Common
Flame detection circuit reporting falselyA wet, cracked or heavily carboned electrode can generate a signal that mimics a flame still burning.Common
Moisture bridging the sensing electrodeCondensate finding its way onto the electrode or its lead creates a conductive path the board reads as ionisation.Occasional
Burner control unit misreading the signalEstablished only after the valve has been tested properly, because the safe assumption has to be the valve.Rare

Can you fix it yourself?

What it costs to fix

Typical repair cost

£140–£500

Electrode replacement with combustion check £140–£230. Gas valve £300–£500 fitted. Both include the safety checks that must follow work on the gas carrying components.

Typical UK prices including parts and labour, updated September 2026. Your quote may differ.

Parts you may need

We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.

Worcester Bosch Greenstar electrode set

87161431020£22–£52Authorised Worcester parts distributor

Price checked 28 September 2026

Own this appliance and had this code? . Nothing is published until a person has read it.

Common questions about Worcester Bosch FA 306

Can I reset it just once?

No. On almost every other code one reset is reasonable. Here the fault the boiler is reporting is gas escaping past a valve that should be closed, and a reset asks the appliance to run again on that assumption. Leave it locked out.

Should I turn the gas off at the meter?

If you can smell gas, leave the property and ring 0800 111 999 rather than doing anything else. If you cannot smell gas, turning the appliance isolation valve off is a sensible precaution and worth mentioning to the engineer when they arrive.

How is this different from F7?

F7 228 is a flame signal seen before the burner starts. FA 306 is a flame signal seen after it stops. The sequence position is what matters: a signal after shutdown implicates the valve holding gas back, which is the more serious of the two.

What will it cost to put right?

An electrode and a combustion check comes to £140 to £230. A gas valve is £300 to £500 fitted. On an older appliance an engineer may reasonably advise you to weigh that against replacement.

Written by

Andrew Pickett

Researcher and writer

Last updated

Technical review

Not reviewed by an engineer

No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.

What we check instead

Sources and how we verified this

We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.

  • Manufacturer technical and service documentation
  • Manufacturer support portal
  • Trade body guidance

This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.

Read our full verification process

Was this page helpful?