Worcester Bosch 2951 fault codewhat it means and how to fix it

Stop — call an engineerBoilerGreenstar 8000 Life, 8000 Style and 8000+, and the Greenstar 4000 and 2000, where the text display shows 2951 alone as a locking fault and 229 is logged in the history for each loss. The Greenstar i and Compact ranges show EA 229 for each loss and have no separate too-many-times code.Last updated

The flame has been lost too many times in a row and the boiler has locked out. Each loss was a 229; Worcester's instruction is to read the history and find what put it out.

Get a Gas Safe registered engineer to look at your Worcester Bosch 2951

We do not pass enquiries to a repair firm, so there is no form here. Find a Gas Safe registered engineer through the Gas Safe Register, and ask to see their registration card when they arrive — it is the register, not the van, that tells you they are qualified.

When does it happen?

The right answer depends on what you can see. Pick the one that matches.

Choose the option on the left that matches what your appliance is doing, and the answer for that case appears here.

It comes on in windy weather and clears later

The flue terminal is the likely culprit — wind driving flue gas back or disturbing the air supply, which Worcester list as incorrectly sited flues and which also produces the 2948 and 2949 blocking codes.

Reset once with the up and down keys. Tell the engineer it is weather-related; that points them at the terminal before anything inside the case.

The boiler is newly installed or the gas supply was recently worked on

Incomplete purging of the gas pipe is on Worcester's list, and so is undersized pipework. Both are installation matters rather than boiler faults.

Call the installer who commissioned it rather than a general engineer; it is their commissioning to finish.

You can smell gas

Stop. This is an emergency, not a fault code.

Turn the gas off at the meter, open windows, do not operate switches, and call the National Gas Emergency Service on 0800 111 999.

What 2951 means

On the Greenstar 8000 Life, 8000 Style, 8000+, 4000 and 2000 the display shows a plain number, and 2951 is one of the locking faults: loss of flame too many times. It is the end of a sequence. Each time the burner is running and the flame goes out the boiler logs 229, flame failed during burner operation, which on these boilers is a blocking fault — it purges and tries again by itself.

When that happens repeatedly within a short spell the board stops trusting the process and locks out on 2951, and it will not run again until someone presses the up and down keys together. Worcester's remedy list is unusually candid about how wide the field is. It starts with a note that the combustion case cover being off can cause it, then says to refer to the blocking errors that led to the lockout in the fault history, then lists incomplete purging of a new gas pipe, and then a wide variety of issues such as undersized pipework or gas pressure dropping off, incorrectly routed condensate drains, incorrectly sited flues and incorrect wiring.

In other words the boiler is telling you it kept losing its flame, and the history menu tells the engineer under what conditions — at high output, in wind, when the hot tap ran. The 229 page on this site covers a single loss; this page is what happens when they add up. It is an ignition-family lockout and Worcester's own guide says to reset once and call if it returns.

What causes it

Causes of the Worcester Bosch 2951 fault code, most common first
CauseWhat is actually happeningHow likely
Gas pressure falling under loadWorcester name undersized pipework and gas pressure dropping off. The flame is fine at low output and starves when the burner asks for more, which is why the history often shows the losses at full rate.Common
Flue or condensate problem putting the flame outIncorrectly sited flues and incorrectly routed condensate drains are on Worcester's list. Recirculating flue gas or a slug of condensate reaching the burner extinguishes it mid-run.Common
Combustion case cover off or not sealedThe note at the top of Worcester's remedy. An unsealed case disturbs the air the burner is metering and the flame lifts off.Occasional
Flame sensing or wiring faultA weak ionisation signal reads as a lost flame even when it is burning. Incorrect wiring is the last item on the manufacturer's list.Occasional

Can you fix it yourself?

What it costs to fix

Typical repair cost

£90–£480

Time on site

1h 30m

Diagnosis and a gas pressure test £90–£160. Electrode and lead £130–£220. Flue terminal re-siting or gas pipe upgrade is an installer's quote and can exceed £400.

Typical UK prices including parts and labour, updated September 2026. Your quote may differ.

Parts you may need

We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.

Worcester Bosch Greenstar electrode set

87161431020£22–£52Authorised Worcester parts distributor

Price checked 28 September 2026

Worcester Bosch Greenstar gas valve

£180–£320Authorised Worcester parts distributor

Price checked 28 September 2026

Condensate trap and siphon

COND-TRAP£15–£38Plumbing merchant

Price checked 28 September 2026

Own this appliance and had this code? . Nothing is published until a person has read it.

Common questions about Worcester Bosch 2951

How many times is too many?

Worcester do not publish the count on the boiler's own display; the manual only says loss of flame too many times and points the engineer at the history menu, which records the 229 events that led to it.

Can I keep resetting it?

No. Worcester's user guide says reset and call if it persists. On the 8000+ and 4000, five locking-fault resets inside fifteen minutes trigger the 2980 super lock-out, which only an engineer can clear.

Is 2951 the same as EA 229?

It is the lockout that follows repeated EA 229 events. On a Greenstar i the display would show EA 229 for each loss; on the 8000 generation you see 229 in the history and 2951 on the screen once the boiler has given up.

Written by

Andrew Pickett

Researcher and writer

Last updated

Technical review

Not reviewed by an engineer

No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.

What we check instead

Sources and how we verified this

We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.

  • Manufacturer technical and service documentation

This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.

Read our full verification process

Was this page helpful?