Worcester Bosch F7 228 fault codewhat it means and how to fix it

Stop — call an engineerBoilerGreenstar rangeLast reviewed

A flame is being detected before the burner has started. Switch the appliance off and get a Gas Safe engineer rather than resetting.

Get a Gas Safe registered engineer to look at your Worcester Bosch F7 228

Gas Safe Register engineers only. No obligation.

What F7 228 means

Worcester describe F7 as a flame detected even though the appliance is switched off, with the 228 sub-code specifying ionisation detected before burner start. There are two possible explanations and they carry very different weight. The likely one is that the sensing circuit is at fault and reporting a flame that does not exist — contamination on the ionisation electrode, moisture across a connector, or a degraded flame amplifier on the control board. The serious one is that the reading is correct and gas is reaching a burner that should be shut off, which means the gas valve is passing. Worcester's own literature is unambiguous that F7 is an engineer's job and instructs householders not to attempt to rectify it. Since neither you nor the appliance can distinguish the two without test equipment, the right response is to treat it as the serious one until proved otherwise. This is one of the few codes where the correct first action is to isolate rather than reset.

What causes it

Causes of the Worcester Bosch F7 228 fault code, most common first
CauseWhat is actually happeningHow likely
Ionisation electrode contaminated or shortingDeposit or moisture creating a conduction path that mimics a flame signal. The most common cause and the benign one.Common
Gas valve passingThe valve not sealing fully when closed. Less common, and the entire reason this code is treated as urgent.Occasional
Moisture in the electrode lead or connectorWater tracking after an internal leak, or condensation in a cold garage or loft installation.Occasional
Control board flame amplifier faultThe board misreading its own input. Diagnosed once the gas side has been proved sound.Rare

Can you fix it yourself?

What it costs to fix

Typical repair cost

£120–£450

An electrode is £120 to £200 fitted. A gas valve is £300 to £450. Expect a diagnostic charge on top, since separating the two needs a flue gas analyser.

Typical UK prices including parts and labour, updated August 2026. Your quote may differ.

Parts you may need

We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.

Worcester Bosch Greenstar electrode set

87161431020£22–£52Authorised Worcester parts distributor

Price checked 5 August 2026

What other owners found

Nobody has shared what worked for them on this code yet. If you have had it, you would be the first — and it genuinely helps the next person.

Common questions about Worcester Bosch F7 228

Is there anything I can try myself first?

No, and unusually the manufacturer says so directly. Worcester put it in writing in their own user literature: do not attempt to rectify F7 yourself. Manufacturers rarely word things that plainly, and it is worth heeding. Turn it off at the fused spur and leave it off.

Should I call Worcester or a local engineer?

Check the guarantee first. Greenstar guarantees run long — considerably longer than people assume — so an appliance you think is out of cover often is not. If it is still covered, book through Worcester directly, because an independent engineer opening the case can end the remaining cover.

How does F7 differ from FA?

F7 is a flame detected before the burner should start; FA is a flame detected after the gas valve has closed. Both concern flame where there should be none. FA is generally treated as the more safety-critical of the two, but neither is a householder repair.

What is the 228 part telling me?

It pins down the moment the ionisation current was measured — 228 is before burner start, whereas 328 relates to a different point in the sequence. Two appliances both showing F7 can need different investigations depending on the suffix, so quote it in full.

Could this just be a damp electrode after the cold snap?

It could, and on a garage or outbuilding installation that is a real possibility. But damp and a passing gas valve produce the same code, and only test equipment can separate them. Worcester's own instruction not to attempt a fix applies either way.

Written by

Fault Code Check editorial team

Updated

Reviewed by

Technical reviewer

Gas Safe registration to be displayed on appointment

Last reviewed

Sources and how we verified this

We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.

  • Manufacturer technical and service documentation
  • Manufacturer support portal
  • Trade body guidance

Checked by Technical reviewer (Gas Safe registration to be displayed on appointment) on 5 August 2026.

Read our full verification process