Skip to content
FaultcodeCheck

Worcester Bosch 2980 fault codewhat it means and how to fix it

Stop — call an engineerBoilerGreenstar 8000+ and 8000+ Style, and the Greenstar 4000 combi, where the text display shows 2980 with the words Boiler locked, contact a qualified heating engineer; Greenstar 2000, which publishes 2981 with the same wording. Not in the 8000 Life or 8000 Style tables read for this page, and not on any Greenstar i, Compact or CDi Classic.Last updated

Super lock-out. Five locking faults were reset inside fifteen minutes while the boiler saw a potentially safety-critical condition, so it has locked itself against further resets. Only an engineer can clear it.

Get a Gas Safe registered engineer to look at your Worcester Bosch 2980

We do not pass enquiries to a repair firm, so there is no form here. Find a Gas Safe registered engineer through the Gas Safe Register, and ask to see their registration card when they arrive — it is the register, not the van, that tells you they are qualified.

What 2980 means

2980 exists because people keep pressing reset. Worcester's Greenstar 8000+ and 4000 combi tables define it precisely: super lock-out occurs when a potential safety-critical condition is detected and five locking faults are reset within a fifteen-minute period. The display reads Locking fault: to unlock hold up and down arrow keys pressed simultaneously for 3 s, followed by Boiler locked, contact a qualified heating engineer, and the user guide gives it a caution box of its own — if 2980 is visible, contact a qualified heating engineer immediately, do not attempt to remedy the fault, otherwise there is a chance this could lead to a serious safety-related fault; heating and hot water will not be available until remedied.

The 2981 that follows is the boiler confirming it is still in super lock-out after the power has been cycled. The clearing procedure is written for the engineer and depends on the original fault having been diagnosed and remedied and the complete system, including sensors and harnesses, checked: only then is the boiler powered off and on, 2981 appears, the up and down arrows are held for three seconds, and after twenty-two seconds a further reset is performed.

The point is that the code is not the fault. Something else — an ignition lockout, a flue fault, an overheat — happened five times and was reset five times without being fixed, and the boiler has decided that the sixth attempt should not be yours to make. What the engineer needs is the history menu, which will show the five faults underneath.

What causes it

Causes of the Worcester Bosch 2980 fault code, most common first
CauseWhat is actually happeningHow likely
A locking fault reset five times without being fixedThe definition. Repeated resets of an ignition lockout such as 227 or 2951, a flue fault such as 2910, or an overheat such as 224 inside fifteen minutes.Common
Frozen condensate pipe in a cold snapThe classic way to reach five resets: the boiler fails to light, is reset, fails again. The condensate pipe is thawed by the householder, but the count has already been reached.Common
Power cycled to try to clear a lockoutSwitching the boiler off and on does not escape the super lock-out; the boiler comes back showing 2981.Occasional

Can you fix it yourself?

What it costs to fix

Typical repair cost

£90–£480

Time on site

1h 30m

The engineer's visit £90–£160, plus whatever the underlying fault turns out to be — an electrode, a gas valve, a flue repair.

Typical UK prices including parts and labour, updated September 2026. Your quote may differ.

Parts you may need

We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.

Worcester Bosch Greenstar electrode set

87161431020£22–£52Authorised Worcester parts distributor

Price checked 28 September 2026

Worcester Bosch Greenstar control board (PCB)

£250–£450Authorised Worcester parts distributor

Price checked 28 September 2026

Own this appliance and had this code? . Nothing is published until a person has read it.

Common questions about Worcester Bosch 2980

Can I clear 2980 myself?

No. Worcester's user guide says do not attempt to remedy the fault. The unlock sequence is published in the installation instructions for the engineer and only works once the underlying fault has been diagnosed and remedied.

What is 2981?

The same condition after a power cycle. The boiler is still in super lock-out and is saying so. The engineer's procedure expects to see it.

Which Worcester boilers have a super lock-out?

The Greenstar 8000+ and 8000+ Style, the Greenstar 4000 combi and the Greenstar 2000, whose tables publish 2980 and 2981. The 8000 Life and 8000 Style tables read for these pages do not include it.

Will I lose heating and hot water?

Yes, until an engineer clears it. Worcester say so in the user guide. Ringing Worcester is free if the boiler is under guarantee.

Written by

Andrew Pickett

Researcher and writer

Last updated

Technical review

Not reviewed by an engineer

No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.

What we check instead

Sources and how we verified this

We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.

  • Manufacturer technical and service documentation

This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.

Read our full verification process

Was this page helpful?