Worcester Bosch Blue light flashingwhat it means
On a Greenstar with no display, the blue light is the fault code. Steady means healthy; a flashing pattern, read with the reset button, is a diagnosis Worcester publish in the installation instructions.
Take care
What is the light actually doing?
The right answer depends on what you can see. Pick the one that matches.
Choose the option on the left that matches what your appliance is doing, and the answer for that case appears here.
Steady blue, and the heating works
Nothing is wrong. That is the appliance saying it has power, and it is what the light does in normal service.
Steady blue but no heating or hot water
Worcester's table has this as the boiler on but not receiving a demand, which points at the controls — a programmer, a thermostat, a room stat with flat batteries — rather than the appliance.
Turn the thermostat well above room temperature and see whether the boiler responds before booking anything.
Slow flash, mostly off, and the reset button is flashing
Ignition lockout. The boiler tried to light and did not detect a flame. In cold weather that is usually the condensate pipe; otherwise gas supply, electrodes or the flue.
Check the condensate pipe and the gas supply, reset once, and if it returns call a Gas Safe registered engineer. Do not keep resetting.
Slow flash, mostly on, and the reset button is flashing
An overheat thermostat has tripped — flue or heat exchanger. Water is not carrying heat away, or the flue is running hot.
Check the pressure and top up if low, reset once, and if it trips again leave it off and book an engineer. Repeated overheats damage the heat exchanger.
Fast flash
With the reset button dark, a sensor, fan or code plug fault the boiler may clear on its own. With the reset button flashing as well, an internal control fault.
Note whether the flashing began immediately after a reset or after about thirty seconds, then book an engineer. That timing is Worcester's own clue to which part it is.
Counted flashes after a five-second dark gap, on a 27Ri or 30Ri Compact
The Ri Compact's own code. One to five slow flashes alone is an ignition or gas fault; four fast flashes then the count is a temperature fault; the count then four fast flashes is electronics. Two slow flashes alone is the common one — a flame lost while running.
Write down the count and where the fast burst falls, reset once with the heating knob, and if it returns give the engineer both numbers. Any group-one code that returns is an ignition fault and needs a Gas Safe registered engineer.
What this means
Several Greenstars were built without a screen — the 24i and 28i Junior, the 25Si and 30Si Mk4, the Ri and the Ri Compact — and on those the blue mains indicator does the job a display would otherwise do. The user guide for these boilers only goes so far: it says the reset button flashes once a second and the blue light flashes to indicate a fault, and tells you to ring Worcester. The installation and servicing instructions for the same boilers go further, and publish the decode. Read the blue light together with the reset button. A slow flash that is mostly off, flicking on, with the reset button flashing, is an ignition lockout — the boiler tried to light and could not. A slow flash that is mostly on, flicking off, with the reset button flashing, is an overheat: the flue thermostat or the heat exchanger thermostat has tripped, and on the Ri the flue pressure switch is added to that list. A fast flash with the reset button dark is what Worcester call a volatile lockout — a temperature sensor, the fan or the code plug — and the Si manual adds a useful tell: if the light starts flashing immediately after a reset the fault is likely the code plug or a sensor, and if it starts after about thirty seconds it is more likely the fan. A fast flash with the reset button also flashing is an internal control fault.
Two pulses or five pulses are not faults at all: an engineer has left the boiler in its minimum or maximum service mode. No light is no power, and a steady light with no heat is a boiler waiting for a demand that is not arriving. That is the whole published account for the Junior, the Si and the 9-24 Ri, and it is enough to tell the difference between a frozen condensate pipe and a failed fan before anyone arrives. The 27Ri and 30Ri Compact from 2015 are different: their installation instructions publish a counted system instead.
After a five-second dark gap the light gives one to five flashes, on its own for group one, preceded by four fast flashes for group two, or followed by four fast flashes for group three — fifteen codes in all. Group one is ignition and gas: one flash is no flame after four attempts, two a flame lost while running, three the gas valve coil disconnected, four the flame not established inside four seconds, five a flame sensed when there should be none or a gas valve leak test failed. Group two is temperature: one is the sensor check at power-up failing, two the heat exchanger past 105 °C, three the flue thermostat or air pressure switch tripped, four the return too hot, five the flow past 110 °C. Group three is electronics: one is the heat control module, two the fan, three power interrupted during a lockout, four an internal board fault, five everything else. Those are the same faults the Compact combis show as EA 227, EA 228, EA 234, EA 261, Fb 365, E9 219, E9 224, D1 286, b1 and C6 215 — the Ri Compact simply has no screen to write them on.
What causes it
| Cause | What is actually happening | How likely |
|---|---|---|
| Ignition lockout — slow flash, mostly off, reset flashing | Worcester's checks are gas present and at pressure, the gas valve solenoids, combustion, a blocked flue, a blocked or frozen condensate pipe, and the ignition electrodes and leads. In winter the condensate pipe is the first suspect. | Common |
| Overheat — slow flash, mostly on, reset flashing | The flue overheat thermostat or the heat exchanger thermostat has tripped. Worcester list water pressure, air in the system, the pump and its wiring, and heat exchanger baffles removed and not refitted after a service. | Common |
| Volatile lockout — fast flash, reset dark | A temperature sensor, the fan or the code plug. The boiler clears this itself when the condition passes, which is why the reset button is not lit. Immediately after a reset points to plug or sensor; after thirty seconds, the fan. | Occasional |
| Internal fault — fast flash, reset flashing | A control board fault. On the Junior, Worcester describe a board reset by holding the service and eco buttons together for about seven seconds until every button flashes; otherwise the board is replaced. | Rare |
What to try yourself
Watch the light for a full minute and decide which pattern it is: mostly off with brief flashes on, mostly on with brief flashes off, or a fast even flash. Then look at the reset button and note whether it is flashing too. On a 27Ri or 30Ri Compact count instead: the number of slow flashes after the five-second gap, and whether a burst of four fast flashes comes before them, after them, or not at all.
If it is the slow, mostly-off pattern in freezing weather, check the white plastic condensate pipe outside. If it is frozen, thaw it with warm — not boiling — water along its length. Worcester's own guide gives this as the householder's check.
Check the pressure gauge reads between 1 and 1.5 bar cold. Low pressure sits behind the overheat pattern, and topping up is yours to do.
Reset once. On a Junior or Si, press the reset button for about five seconds until it goes out. On an Ri or Ri Compact there is no button: turn the heating temperature knob fully anticlockwise to RESET, hold it for five seconds, and turn it back.
Once. If the slow mostly-off pattern returns, the boiler is failing to light, and repeated resets on an ignition fault are not safe. Call a Gas Safe registered engineer.Tell whoever comes which pattern you saw and whether the reset button was flashing. That is the decode Worcester give their engineers, and it turns a vague call into a specific one.
Get a Gas Safe registered engineer to look at your Worcester Bosch boiler
We do not pass enquiries to a repair firm, so there is no form here. Find a Gas Safe registered engineer through the Gas Safe Register, and ask to see their registration card when they arrive — it is the register, not the van, that tells you they are qualified.
What it costs to fix
Typical repair cost
£0–£120
Time on site
10 minutes
Nothing to read the pattern and reset. A diagnostic visit is £70–£120 before parts, and free if the appliance is still under Worcester guarantee.
Typical UK prices including parts and labour, updated September 2026. Your quote may differ.
Parts you may need
We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.
Worcester Bosch Greenstar heat control module (HCM) or code plug
£30–£90Authorised Worcester parts distributor
Price checked 28 September 2026
Condensate trap and siphon
COND-TRAP£15–£38Plumbing merchant
Price checked 28 September 2026
Own this appliance and had this code? . Nothing is published until a person has read it.
Related Worcester Bosch fault codes
- F0Get it checkedThe boiler has found a fault inside its own electronics and stopped. F0 covers the control board and the burner control unit, and it needs an engineer.Related: electronics and power
- A7Get it checkedThe hot water temperature sensor has failed. Heating usually carries on as normal while the hot water runs cold, scalding, or swings between the two.Related: electronics and power
- Red light flashingGet it checkedOn a Worcester built before the Greenstar era, the flashing lights are the fault code. Slow means a lockout you can reset once; fast means a fault the boiler is waiting out or an engineer's.Related: electronics and power
- 9U 233Get it checkedThe heat control module is loose, missing or faulty. This small plug-in part carries the identity of your boiler, and nothing runs without it.Related: electronics and power
- Fd 231Get it checkedPower to the boiler was cut while it sat in a lockout, so a fault happened before the interruption. On older Greenstars, Fd simply means the reset button was pressed by mistake.Related: electronics and power
- 2980Stop — call an engineerSuper lock-out. Five locking faults were reset inside fifteen minutes while the boiler saw a potentially safety-critical condition, so it has locked itself against further resets. Only an engineer can clear it.Related: electronics and power
Own a Worcester Bosch boiler? Save it and its codes come first next time.
Related guides
Common questions
Does a slow flash mean standby?
No. Worcester's installation instructions give the two slow patterns as ignition lockout and overheat, and neither is standby. Repair sites that say a slow flash is normal have not read the table. If it is flashing and the boiler is not working, it is a fault.
Which Greenstar models have no display?
The 24i and 28i Junior, the 25Si and 30Si Mk4, the 9-24 Ri and the 27Ri and 30Ri Compact. The first three share the slow-and-fast pattern table; the Ri Compact counts flashes in three groups instead. The Greenstar i and i System from 2015 do have a display, behind the flap, and on those the light is not the diagnostic — read the letter pair and number instead.
Where did the decode come from if the user guide does not have it?
From the installation and servicing instructions for the same boilers, which Worcester publish on their website in the professional literature library. The user guide says to ring Worcester; the installer's manual says what the engineer will be looking at when they arrive.
What does two or five pulses mean?
Not a fault. An engineer has left the boiler in service mode — two pulses for minimum output, five for maximum — and Worcester's remedy is to press the service button, or on the Ri return the mode switch to NORM.
What does it cost to have someone look at it?
A diagnostic visit runs £70 to £120 before parts. If the appliance is still under Worcester guarantee, ringing Worcester first costs nothing.
Technical review
Not reviewed by an engineer
No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.
Sources and how we verified this
We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.
- Manufacturer technical and service documentation
- Manufacturer support portal
This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.