Skip to content
FaultcodeCheck

Worcester Bosch H27 fault codewhat it means and how to fix it

Usually simple to fixBoilerGreenstar Heatslave II 12/18, 18/25 and 25/32, internal and External ErP+, on the controller with the warning triangle and no flashing blue light. The gas Greenstar i publishes its own H family, from H03 to H29, on the maintenance codes pages.Last updated

A warning triangle with H27 means the sensor on the incoming cold mains has failed. Worcester say operation is not affected, so heating and hot water carry on until the sensor is replaced.

Before you start

This one is usually safe to look at yourself. Do not remove any panel that is held on with screws or clips — everything below is done from the outside of the boiler.

What H27 means

H27 is the gentlest thing the Heatslave II can show you. Table 13 of the 2022+ manual lists two H codes for this boiler, and both come with a warning triangle rather than a flashing blue light: H27, "DCW in sensor defect (appliance operation not affected)", and H29, weather compensation activated but no weather sensor detected. DCW is domestic cold water, and the sensor in question reads the temperature of the mains water coming into the boiler. It matters more on this boiler than on most because of what the Heatslave does with the reading.

The manual's solar compatibility section describes the logic: if the incoming water is already warm — from a solar pre-heat cylinder, say — the burner is held off for hot water above a certain flow, and if it arrives above 80 °C the burner and pump are stopped altogether with 380 recorded in the service menu. Without a working inlet sensor the boiler cannot make those judgements, so it falls back to running as though the water were cold, which is why Worcester can say operation is not affected: you lose an efficiency, not a function.

Because it is an H code the boiler carries on; a reset will not clear a sensor that has failed, and the code is there to be noted rather than acted on urgently. The repair is a sensor on the cold inlet pipe inside the case, and it belongs with the next service or a visit at your convenience rather than an emergency call. The codes the Heatslave shares with Worcester's gas boilers behave the same way — the Greenstar i manual describes its H family as a situation that will need some attention while the boiler continues — and H29 on the Heatslave is the same H29 the Greenstar i shows when weather compensation is switched on with no outdoor sensor connected.

What causes it

Causes of the Worcester Bosch H27 fault code, most common first
CauseWhat is actually happeningHow likely
Inlet sensor failedA thermistor on the cold mains inlet that has failed open or short reads as a defect, and the boiler flags it and carries on without the reading.Common
Connector or lead disturbedThe sensor lead runs to the low-voltage strip in the control box. A plug not pushed home after a service, or a lead caught when the panels went back on, gives the same H27.Occasional

What to try yourself

  1. Confirm what you are seeing: a warning triangle with H27 and the blue light steady, not a flashing blue light with a letter pair and a three-digit number. If the blue light is flashing, look up that code instead — it is the one stopping the boiler.

  2. Check that the heating and the hot water are both working normally. Worcester say H27 does not affect operation, so if either has stopped there is a second fault to find, and that is the one to report.

  3. Note the code and book the sensor replacement with your next service, or at a convenient time. It is a small sensor on the cold inlet inside the case — an OFTEC registered technician's job, but not an urgent one.

  4. If solar-heated water feeds this boiler, mention it when you book. The boiler uses this sensor to decide when the burner can stay off for pre-heated water, so that saving is lost until the sensor is replaced.

Get an OFTEC registered technician to look at your Worcester Bosch H27

We do not pass enquiries to a repair firm, so there is no form here. Find an OFTEC registered technician through the OFTEC, and ask to see their registration card when they arrive — it is the register, not the van, that tells you they are qualified.

What it costs to fix

Typical repair cost

£80–£160

Time on site

30 minutes

Not urgent, so fold it into a service: the sensor is a small part and the extra time is short. On its own, a call-out with the sensor fitted is typically £80–£160.

Typical UK prices including parts and labour, updated September 2026. Your quote may differ.

Parts you may need

We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.

Worcester Bosch Heatslave II cold water inlet (DCW) sensor

£15–£45Authorised Worcester parts distributor

Price checked 28 September 2026

Own this appliance and had this code? . Nothing is published until a person has read it.

Common questions about Worcester Bosch H27

What about H29 with a house symbol?

The Heatslave II’s other H code: weather compensation is switched on in the settings but no outdoor sensor is connected. Worcester’s manual refers the installer to its weather compensation section. Either the sensor needs connecting or the setting needs turning off, both installer jobs, and like H27 it does not stop the boiler.

Will it clear if I press reset?

No. The reset clears lock-outs; an H code reports a condition, and the condition is a sensor that has failed. It stays until the sensor is replaced, and the boiler runs normally in the meantime.

Is it urgent?

Not by Worcester's own description, which says appliance operation is not affected. Treat it as something for the next service unless you rely on solar pre-heated water, in which case the boiler is burning oil it would otherwise have saved.

Written by

Andrew Pickett

Researcher and writer

Last updated

Technical review

Not reviewed by an engineer

No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.

What we check instead

Sources and how we verified this

We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.

  • Manufacturer technical and service documentation

This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.

Read our full verification process

Was this page helpful?