Worcester Bosch E2 222 fault codewhat it means and how to fix it
The flow temperature sensor is giving a reading the appliance cannot trust. Usually the sensor rather than the temperature.
Take care
Get a Gas Safe registered engineer to look at your Worcester Bosch E2 222
Gas Safe Register engineers only. No obligation.
What E2 222 means
E2 is a flow temperature sensor fault, with 222 as the sub-code Worcester use for the flow temperature condition. The flow sensor reports the temperature of water leaving the heat exchanger, and virtually every operating decision the appliance makes depends on it — how hard to fire, when to modulate down, when to stop. When that reading becomes implausible, whether open circuit, short circuit, or simply a value outside anything physically sensible, the appliance shuts down rather than operating blind. Two quite different situations produce this. The more common is that the sensor or its wiring has failed, in which case the water temperature is perfectly normal and only the measurement is wrong. The less common is that the temperature genuinely is extreme because circulation has stopped, in which case the sensor is working correctly and telling you something important. Those need entirely different repairs, which is why an engineer measures the sensor resistance rather than simply replacing it.
What causes it
| Cause | What is actually happening | How likely |
|---|---|---|
| Flow sensor failed | Thermistors drift out of tolerance with years of thermal cycling. The most likely cause and among the cheaper faults on a Greenstar. | Common |
| Wiring or connector fault | A chafed lead or a corroded connector produces exactly the same symptom as a dead sensor at a fraction of the cost. | Occasional |
| Genuine high temperature from circulation failure | The sensor is right and the water really is that hot. Usually accompanied or shortly followed by an E9 overheat code. | Occasional |
| Control board input fault | The board cannot read a healthy sensor. Concluded only after the sensor has been measured and found within tolerance. | Rare |
Can you fix it yourself?
Stop — this needs an engineer
What it costs to fix
Typical repair cost
£110–£480
A flow sensor is typically £120 to £200 fitted. A wiring repair is a call-out charge of £80 to £150. A control board, if it comes to that, is £350 to £550.
Typical UK prices including parts and labour, updated August 2026. Your quote may differ.
What other owners found
Nobody has shared what worked for them on this code yet. If you have had it, you would be the first — and it genuinely helps the next person.
Related Worcester Bosch fault codes
- E9 219Stop — call an engineerThe boiler has overheated and the safety thermostat has tripped. Water is not carrying heat away from the exchanger, and it should not be run until that is fixed.Related: overheat and circulation
- A1 229Stop — call an engineerThe boiler has detected a dry-fire condition — it is trying to heat water that is not moving. Turn it off and leave it off until an engineer has seen it.Related: overheat and circulation
- L1Get it checkedThe boiler is not seeing enough water flow through it to run safely, so it has stopped. Usually a pump, an air lock, or a blocked filter.Related: overheat and circulation
- E02Get it checkedThe overheat thermostat has tripped. Almost always this means water is not moving through the appliance properly rather than that it is running too hot.Related: overheat and circulation
- F.20Stop — call an engineerThe overheat thermostat has tripped because the boiler got too hot. It has shut down to protect itself and it should not be restarted repeatedly.Related: overheat and circulation
- A02Get it checkedThe safety limit thermostat has tripped on overheat. In practice this nearly always means water has stopped circulating properly.Related: overheat and circulation
Related guides
Sources and how we verified this
We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.
- Manufacturer technical and service documentation
Checked by Technical reviewer (Gas Safe registration to be displayed on appointment) on 5 August 2026.