Skip to content
FaultcodeCheck

Worcester Bosch E9 224 fault codewhat it means and how to fix it

Stop — call an engineerBoilerGreenstar i and i System ErP, where the text display reads Temperature fault with E9 above and 224 below; Greenstar CDi Compact, Si Compact and 27i/30i System Compact, where 224 is the locking code shown under E9 and 210 — flue gas thermostat or air pressure switch activated — is the blocking stage before it. On the CDi Classic the display shows E9 alone. Greenstar 8000 Life, 8000 Style, 8000+, 4000 and 2000 show 224 alone; the 8000 Life describes it as the maximal flue gas thermostat or heat exchanger maximal thermostat activated, and the 4000 and 2000 as the safety temperature limiter tripped, a blocking fault that becomes locking if it persists.Last updated

One of the two safety thermostats has tripped: the flue overheat thermostat or the high-limit stat on the heat exchanger. Worcester's own check list includes the burner gasket for flue gas leakage.

Get a Gas Safe registered engineer to look at your Worcester Bosch E9 224

We do not pass enquiries to a repair firm, so there is no form here. Find a Gas Safe registered engineer through the Gas Safe Register, and ask to see their registration card when they arrive — it is the register, not the van, that tells you they are qualified.

What happens when you reset it?

The right answer depends on what you can see. Pick the one that matches.

Choose the option on the left that matches what your appliance is doing, and the answer for that case appears here.

It runs for a while, then locks out on 224 again

A thermostat is genuinely reaching its limit each cycle. Either the water is not carrying heat away or the flue gases are too hot, and both need the case off to tell apart.

Leave the boiler off and book a Gas Safe registered engineer. Repeated cycles into an overheat are what damage the heat exchanger.

It locks out on 224 again straight away, stone cold

Nothing can be overheating from cold, so the safety circuit itself is open — a thermostat that has failed, or a harness connector that has come adrift.

Still an engineer visit, but tell them this: it points them straight at the thermostats and wiring rather than the pump and system.

There is a smell of fumes near the boiler

Combustion products may be escaping inside the case. That is the burner gasket scenario Worcester list, and it is the reason this code is treated as a danger code.

Switch the boiler off, open windows, and do not use it until an engineer has checked the flue and burner seal. If anyone feels unwell, leave the property and call 0800 111 999.

What E9 224 means

Worcester's Greenstar i table lists this under "Temperature fault" as E9 with cause code 224, described as "flue or high limit thermostat activated (safety circuit)". The Compact family manuals put it more bluntly: "max temperature thermostat activated — flue gas thermostat overheat". It is a different fault from E9 219, which is the electronic safety sensor reading too hot. Here a physical thermostat has opened. Two of them sit in one series loop: a flue overheat thermostat clipped to the flue outlet, and a high-limit stat on the heat exchanger body.

If either one opens, the control board loses the circuit and locks out with 224. The engineer's checks in Worcester's order are the thermostat harness and connector, the operation of both thermostats, circulation through the heating system, the burner gasket for leakage of flue gases, the heat exchanger for debris, and the air-gas ratio.

Two of those six are about combustion products escaping where they should not, which is why this page carries no steps for you to try. A flue thermostat that keeps tripping is telling you the flue gases are hotter than they should be, and the usual reasons are a heat exchanger fouled with debris on the combustion side or a burner running off-ratio. A high-limit stat that keeps tripping is a circulation problem that the pump, air locks or sludge will explain. Worcester describe a reset as a brief press of the reset button on the i and Compact ranges, but the fault will simply return until the thermostat that opened has been found and the reason for it dealt with.

What causes it

Causes of the Worcester Bosch E9 224 fault code, most common first
CauseWhat is actually happeningHow likely
Poor circulation through the heat exchangerA failing pump, an air lock or a sludged system lets the exchanger get hot enough to open the high-limit stat even though the burner is modulating normally.Common
Flue gases running too hotDebris on the combustion side of the heat exchanger, or an air-gas ratio that has drifted, sends hotter products up the flue and trips the flue overheat thermostat.Common
Burner gasket leakingWorcester name this specifically. A deteriorated gasket lets hot combustion products escape past the burner and heat parts of the appliance the thermostats protect.Occasional
Thermostat or harness faultA corroded connector or a thermostat that has failed open gives 224 with nothing actually overheating. The engineer proves this with a continuity check before condemning anything else.Occasional

Can you fix it yourself?

What it costs to fix

Typical repair cost

£90–£450

Time on site

1h 30m

Flue or high-limit thermostat £90–£180 fitted. Heat exchanger combustion-side clean £120–£250. Pump £280–£450.

Typical UK prices including parts and labour, updated September 2026. Your quote may differ.

Parts you may need

We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.

Central heating circulating pump

CH-PUMP-15-60£90–£180Plumbing merchant

Price checked 28 September 2026

Worcester Bosch Greenstar high limit thermostat

87072061960£15–£45Authorised Worcester parts distributor

Price checked 28 September 2026

Worcester Bosch Greenstar flue overheat thermostat

87105062670£20–£50Authorised Worcester parts distributor

Price checked 28 September 2026

Own this appliance and had this code? . Nothing is published until a person has read it.

Common questions about Worcester Bosch E9 224

Is 224 the same as E9 219?

No. Both are E9 temperature faults and both stop the boiler, but 219 is the electronic safety sensor on the heat exchanger reporting too high a temperature, and 224 is a mechanical thermostat in the flue or on the exchanger physically opening. They have overlapping causes but an engineer diagnoses them differently.

My display just says E9 with no number — is that this fault?

On a Greenstar CDi Classic the display only ever shows the two characters, and Worcester describe E9 there as the safety temperature limiter in the flow having tripped. Treat it as the same family of overheat fault. On a Greenstar i or Compact you can read the three-digit number in the info menu or, during a lockout, flashing under the letters.

Can I reset it and carry on?

You can press reset once — Worcester's user guide allows that — but if 224 comes back, stop. Each overheat cycle stresses the heat exchanger, and if the cause is flue gas leaking past the burner gasket, running the boiler is not safe.

What does the repair cost?

If it is a thermostat or connector, around £90 to £180 including the visit. A combustion-side clean of the heat exchanger at a service is £120 to £250. If the pump has failed, £280 to £450. A burner gasket is cheap as a part but is fitted as part of a strip-down and combustion check.

Written by

Andrew Pickett

Researcher and writer

Last updated

Technical review

Not reviewed by an engineer

No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.

What we check instead

Sources and how we verified this

We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.

  • Manufacturer technical and service documentation

This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.

Read our full verification process

Was this page helpful?