Worcester Bosch A8 fault codewhat it means and how to fix it
The boiler has lost communication with a Worcester control on the two-wire bus — a Sense, FX or FW controller, or a Wave thermostat. Heating usually carries on at the boiler's own settings.
Take care
What A8 means
A8 is the communication fault across every Worcester generation, and only the wording changes. The Greenstar CDi Classic table gives it as "break in communication to FX/Sense controls — check electrical connections"; the earlier CDi combi and system manuals say the same about the TD200 and RT10 controls of their day; the Highflow manual calls it "EMS communication error".
On the Greenstar i ErP the letters gain a cause code and a narrower meaning — A8 361, "HCM invalid: the inserted HCM does not correspond with the control box or HMI type", which is an internal mismatch rather than a wiring one. What all the bus versions share is the two-terminal EMS connection, marked B B on the boiler and on the control, over which a Worcester programmer or thermostat talks to the board. Break that pair, wire it to the wrong terminals, or fit a control the board does not recognise, and A8 appears.
Worcester's service booklet for the CDi Classic walks the engineer through it in order: continuity of the B wires between controller and boiler, then any branch box and bus module in between, then the programmer, then the bus module, and only then the control board. The boiler itself is usually not the problem. It keeps making heat, because the fault is in the instruction path rather than the burner, and the practical effect is that the room control has stopped talking to it.
What causes it
| Cause | What is actually happening | How likely |
|---|---|---|
| Loose or broken bus wiring | The two B wires run from the boiler terminal strip to the controller's wall plate. A backing plate pulled off the wall or a screw terminal worked loose is the usual break. | Common |
| Control wired to the wrong terminals | Worcester's booklet is specific that the B terminals must be used and the centre terminal must not carry a bus connection. A control fitted onto switched-live terminals cannot communicate. | Common |
| Controller or bus module failure | A programmer with a dead display, or a plug-in bus module that has failed, breaks the conversation at one end. Worcester have these replaced before the boiler's own board. | Occasional |
| Wrong heat control module on a Greenstar i | A8 361 on the i-series is a module that does not match the board or display it is plugged into, typically after a part has been swapped for the wrong variant. | Rare |
What to try yourself
Check the room controller. If its display is blank or it shows its own communication warning, the break is at that end — a wall plate that has come loose is worth pressing home.
Reset the boiler using the procedure for your range: three seconds on the reset button for a CDi Classic, a brief single press on a Greenstar i or Compact.
If the code clears and returns, leave the controller alone and book an engineer. Bus wiring runs at low voltage but it terminates inside the boiler casing, which is not for you to open.
Get a Gas Safe registered engineer to look at your Worcester Bosch A8
We do not pass enquiries to a repair firm, so there is no form here. Find a Gas Safe registered engineer through the Gas Safe Register, and ask to see their registration card when they arrive — it is the register, not the van, that tells you they are qualified.
What it costs to fix
Typical repair cost
£0–£250
Time on site
45 minutes
Free if it is a wall plate pressed home. Wiring repair or re-termination £90–£160. Replacement programmer or bus module £120–£250 fitted.
Typical UK prices including parts and labour, updated September 2026. Your quote may differ.
Parts you may need
We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.
Worcester Bosch Greenstar control board (PCB)
£250–£450Authorised Worcester parts distributor
Price checked 28 September 2026
Worcester Bosch Greenstar heat control module (HCM) or code plug
£30–£90Authorised Worcester parts distributor
Price checked 28 September 2026
Own this appliance and had this code? . Nothing is published until a person has read it.
Related Worcester Bosch fault codes
- H09Get it checkedThe control board has lost its data link to the pump. The boiler keeps running, but Worcester flag it because a pump the board cannot talk to is either wired wrongly or the wrong pump.Related: electronics and communication
- A6Get it checkedThe boiler thinks an external limit thermostat has opened — usually the underfloor heating stat — or the link that stands in for one is missing. Nothing runs until that circuit is closed again.Related: electronics and communication
- EA 227Stop — call an engineerThe boiler tried to light and never detected a flame, so it has shut the gas off and locked out. This is the most common Worcester fault code.Related: same brand
- CE 207Get it checkedSystem water pressure has dropped too low for the boiler to run safely. Topping the system back up to 1.2 bar usually clears it in five minutes.Related: same brand
- E9 219Stop — call an engineerThe boiler has overheated and the safety thermostat has tripped. Water is not carrying heat away from the exchanger, and it should not be run until that is fixed.Related: same brand
- C6 224Get it checkedThe fan is not reaching the speed the boiler asked for, so combustion cannot be confirmed as safe and the burner has been prevented from firing.Related: same brand
Own a Worcester Bosch boiler? Save it and its codes come first next time.
Related guides
Common questions about Worcester Bosch A8
Will I lose heating while A8 is showing?
Usually not. The boiler falls back to running on its own dials, so you may have heat you cannot time or set from the room. Hot water on a combi is unaffected.
I have just fitted a smart thermostat and now it shows A8.
If the old Worcester controller was on the bus and the new one is a switched-live thermostat, the boiler may still be configured for bus control. An engineer can either remove the bus expectation or fit the new stat correctly; either way it is a settings and wiring visit, not a boiler repair.
My display says A8 with 361 under it.
That is the Greenstar i's internal version: the heat control module does not match the control box or display. It follows a part change rather than a wiring fault, and the fix is the correct module. Quote both halves when you call.
Technical review
Not reviewed by an engineer
No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.
Sources and how we verified this
We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.
- Manufacturer technical and service documentation
This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.