Skip to content
FaultcodeCheck

Worcester Bosch SE status codewhat it means

Usually simple to fixBoilerGreenstar CDi Classic and the Heatronic 3 generation with a two-character display, where SE alternates with the flow temperature. The Greenstar i and 8000 ranges publish the reminder as text and H codes instead.Last updated

SE alternating with the temperature on a CDi Classic is a service reminder, not a fault. The burner has run the hours Worcester equate to a year, and the boiler wants its annual check.

Before you start

This one is usually safe to look at yourself. Do not remove any panel that is held on with screws or clips — everything below is done from the outside of the boiler.

What SE means

On the Greenstar CDi Classic and its Heatronic 3 relatives the display normally shows the flow temperature. When it starts alternating that temperature with SE, the boiler is telling you it is due a service. Worcester's engineer booklet explains the mechanism: "the burner has run for 2324 hours since the boiler has been checked last", 2324 hours being Worcester's average of a year's burner running time. The booklet then asks the engineer a sensible question — when was the boiler actually checked last?

If it was twelve months or more ago, do the annual combustion and safety check. If it was more recent, the burner has simply run for longer than average, probably at lower output and higher efficiency, and there is no need to check the boiler yet. Either way the code is cleared through the service menu, function 5.A, which is an engineer procedure involving holding the service button until it glows orange and stepping through the menu with the eco button. It cannot be cleared by the reset button and it does not need to be, because it does not stop the boiler doing anything.

Heating and hot water continue exactly as before. The Greenstar i and the 8000 Life do the same job with text — "Planned maintenance required" and the H03, H08 and H13 maintenance codes — so if your display is showing words rather than SE, that page is the one you want.

What causes it

Causes of the Worcester Bosch SE status code, most common first
CauseWhat is actually happeningHow likely
A year's burner hours have accumulatedWorcester's threshold is 2324 hours of burner operation since the reminder was last reset, which they take to represent twelve months of typical use.Common
Reminder not reset at the last serviceIf the engineer serviced the boiler but did not clear function 5.A, the counter carried on from where it was and the reminder arrives early.Common
Heavy useA boiler running a large house or one left on constant reaches 2324 hours well inside a year. Worcester's booklet says this alone is not a reason to service early.Occasional

What to try yourself

  1. Check when the boiler was last serviced. If it is a year or more, book an annual service with a Gas Safe registered engineer — that is all the code is asking for.

  2. Ask the engineer to reset the service reminder through service function 5.A when they have finished. If they do not, SE will return before its time.

  3. Do not press reset repeatedly to try to clear it. SE is not a lockout, the reset button has no effect on it, and the boiler is running normally underneath.

Get a Gas Safe registered engineer to look at your Worcester Bosch SE

We do not pass enquiries to a repair firm, so there is no form here. Find a Gas Safe registered engineer through the Gas Safe Register, and ask to see their registration card when they arrive — it is the register, not the van, that tells you they are qualified.

What it costs to fix

Typical repair cost

£80–£150

Time on site

1 hour

An annual service is £80–£150 and includes resetting the reminder.

Typical UK prices including parts and labour, updated September 2026. Your quote may differ.

Own this appliance and had this code? . Nothing is published until a person has read it.

Common questions about Worcester Bosch SE

Is the boiler safe to use while SE is showing?

Yes. Worcester describe SE as a service reminder and it does not interrupt operation. It is asking for the annual check that keeps the boiler efficient and the guarantee valid.

Can I clear it myself?

Not without entering the service menu, which Worcester document for engineers. The sequence involves holding the service button for ten seconds and stepping to function 5.A. Leave it for the engineer at the service visit.

What does the Greenstar i show instead?

Words. The Greenstar i and the 8000 ranges display Planned maintenance required and log an H code — H03 for burner hours, H08 for a set date, H13 for a set interval in months. Same idea, different display.

Written by

Andrew Pickett

Researcher and writer

Last updated

Technical review

Not reviewed by an engineer

No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.

What we check instead

Sources and how we verified this

We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.

  • Manufacturer technical and service documentation

This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.

Read our full verification process

Was this page helpful?