Skip to content
FaultcodeCheck

Potterton E270 fault codewhat it means and how to fix it

Get it checkedBoilerDigital display, flashing 270 without an R symbol: Potterton Assure Combi and System (2019–2023), Promax Ultra Combi (2015–2019). Not on the Promax, Titanium or Gold tables.Last updated

Circulation fault (dry fire) on the Potterton Assure and Promax Ultra: the burner lit with too little water passing the heat exchanger. Not resettable by the owner; engineer.

Take care

Some of this is safe to check yourself, but the repair itself is not. If the fault comes back after one reset, stop resetting it and get a Gas Safe registered engineer to look at the Potterton properly.

Get a Gas Safe registered engineer to look at your Potterton E270

We do not pass enquiries to a repair firm, so there is no form here. Find a Gas Safe registered engineer through the Gas Safe Register, and ask to see their registration card when they arrive — it is the register, not the van, that tells you they are qualified.

What does the pressure gauge show?

The right answer depends on what you can see. Pick the one that matches.

Choose the option on the left that matches what your appliance is doing, and the answer for that case appears here.

Low or zero

The system has lost water and the exchanger ran dry.

Do not refill and restart repeatedly; an engineer should check the exchanger for damage first.

Normal

Pump, air or a sensor.

Engineer.

What E270 means

"270 — Circulation fault (Dry fire)" is in the Assure and Promax Ultra tables and nowhere in the older Potterton manuals. It is the most serious of the circulation codes because of what it describes: the burner was firing while the heat exchanger had little or no water flowing through it, which is how aluminium heat exchangers get damaged.

The control detects it from the temperature sensors — a flow temperature climbing far faster than the return, or a spread between them that cannot happen with water moving — and shuts the burner down. It is not on either manual's reset list and the Assure user guide shows it without the R, so the boiler decides when it is safe to try again.

The causes are the E125 and 109 causes with less margin: a pump that has stopped, an air pocket at the exchanger, a system that has lost most of its water without the pressure switch having tripped yet, or a flow sensor giving a false reading. Potterton's Assure user guide does not describe 270 to the owner beyond listing it; the installer manual's section J (pump and circulation) is where the engineer goes. Treat it as a stop-and-call code.

What causes it

Causes of the Potterton E270 fault code, most common first
CauseWhat is actually happeningHow likely
Pump stopped with the burner able to lightThe pre-circulation test passed on residual movement and the pump then stalled, or its speed collapsed under load.Common
Air pocket at the heat exchangerSensors in air heat fast and unevenly. Follows a top-up or a system drain.Common
Flow or return sensor faultA sensor reading high (part 7207471, listed as "flow sensor and return sensor") makes the control see a dry fire that is not happening. 154 is the related sensor-test code.Occasional

Can you fix it yourself?

What it costs to fix

Typical repair cost

£60–£600

Time on site

1 hour

Pump £180–£300 fitted. Sensor £60–£110. Heat exchanger £450–£600.

Typical UK prices including parts and labour, updated September 2026. Your quote may differ.

Parts you may need

We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.

Baxi / Potterton / Main NTC temperature sensor (flow, return or DHW)

7207471£18–£45Authorised Baxi parts distributor

Price checked 28 September 2026

Baxi / Potterton / Main pump assembly

7684006£120–£240Authorised Baxi parts distributor

Price checked 28 September 2026

Baxi / Potterton / Main automatic air vent

7207776£15–£45Authorised Baxi parts distributor

Price checked 28 September 2026

Own this appliance and had this code? . Nothing is published until a person has read it.

Own a Potterton boiler? Save it and its codes come first next time.

Written by

Andrew Pickett

Researcher and writer

Last updated

Technical review

Not reviewed by an engineer

No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.

What we check instead

Sources and how we verified this

We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.

  • Manufacturer technical and service documentation

This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.

Read our full verification process

Was this page helpful?