Potterton E119 fault codewhat it means and how to fix it

Get it checkedBoilerTwo-character window beside the ON/OFF/RESET selector knob, showing E1 and then 19 in turn: Potterton Promax Combi HE Plus, HE A and Promax Combi 24/28/33 (2008–2019), Promax System (2008–2019), Promax Store, Titanium Combi (2012–2017), Gold Combi HE, HE A, Gold Combi and Gold System (2007–2019), Promax Heatmax HE. Assure and Promax Ultra owners with a digital display see 118 instead.Last updated

The sealed system on a rotary-switch Potterton — Promax, Titanium, Gold, Heatmax — has dropped below half a bar. The window shows E1 and then 19. Fill to 1–1.5 bar and it clears itself.

Take care

Some of this is safe to check yourself, but the repair itself is not. If the fault comes back after one reset, stop resetting it and get a Gas Safe registered engineer to look at the Potterton properly.

How often does the Potterton need topping up?

The right answer depends on what you can see. Pick the one that matches.

Choose the option on the left that matches what your appliance is doing, and the answer for that case appears here.

First time, or once a year

Normal for a sealed system. Fill and carry on.

Nothing further unless it recurs within a few weeks.

Every few weeks

The guide's "regular re-pressurising" — a leak, or an expansion vessel that has lost its charge.

Tenants: report it in writing with the dates. Owners: book a leak trace and vessel check.

Gauge is above 1 bar but E119 stays

The switch or its wiring, not the water. The boiler cannot see the pressure the gauge shows.

Engineer: a quick diagnosis and a cheap part.

What E119 means

Every Promax, Titanium and Gold manual from 2007 to 2017 defines the code by a single threshold, and the sentence does not change between ranges: the primary circuit has fallen below half a bar. The table row behind it names the water pressure switch as the part that has not operated, which tells you how a Potterton knows — a switch on the hydraulic block that stays open until there is enough water behind it.

Potterton write the user guides for a householder who has never touched a boiler, so the E119 paragraph adds something the other codes do not get: once the system is back up to pressure the boiler is expected to run again, and the installer is named as the person to ask about how to repressurise. The repressurising section that follows it is unusually specific about Potterton hardware. The filling loop supplied with these boilers is not a braided hose left in place; it is two blue-handled isolating taps under the right-hand side of the boiler with a separate temporary filling pipe that must be connected for the top-up and removed afterwards, blanking caps refitted.

Many installers fitted a permanent loop on the pipework instead, so look for either. The Potterton installed base is heavily rented and social housing, and the relevant point for a tenant is that E119 is not a repair: the user guide gives you the procedure, and a boiler that needs it more than a couple of times a season is what you report.

What causes it

Causes of the Potterton E119 fault code, most common first
CauseWhat is actually happeningHow likely
Water has left the system somewhereThe Promax user guide says it plainly: pressure below 0.5 bar "may indicate a leak on the central heating system", and "if the water pressure requires regular re-pressurising a fault or leak is indicated". Gland nuts on radiator valves, a corroded panel, a fitting under the floorboards.Common
Expansion vessel has lost its chargeWith no air cushion the pressure climbs to 3 bar on heating and the relief valve lets water out through the wall. By morning the gauge is under 0.5 bar again. A common finding on a Promax past ten years old.Common
Switch contacts not closing, or the lead to themSection A of the Promax fault-finding chart: with the gauge reading over half a bar and E119 still up, check the switch connection (COM–NO to PCB connector X400) and replace the water pressure switch, part 5114748 in the Promax Combi parts list.Occasional
Air worked out of a newly filled systemAfter a repair or a radiator change the pressure drops as trapped air bleeds off. One further top-up is expected; the user guide's "regular" is the threshold for calling someone.Occasional

What to try yourself

  1. With the boiler cold, read the pressure gauge on the front panel. The Promax and Titanium user guides want at least 0.5 bar cold and normally 1 to 1.5; the green sector on the gauge runs from 1 to 2.5.

  2. Look underneath the right-hand side of the boiler for two blue-handled taps. If they carry blanking caps, remove the caps and fit the temporary filling pipe between them, flanged washers at both ends, wing nuts tightened. If a permanent loop with two valves is fitted on the pipework instead, use that.

  3. Fully open one blue tap first, then open the second slowly while watching the gauge. When the needle is between 1 and 2 bar, close both taps.

    Do not go above 2.5 bar. At 3 bar the safety valve opens, and Potterton's guide treats that as a fault to report to your installer.
  4. Remove the temporary pipe, refit the blanking caps and keep the pipe somewhere you will find it. Leaving it connected is the mistake Potterton's guide warns about, because a passing tap can then flood the system to the relief valve.

  5. The display should return to the temperature. Do not turn the selector to Reset; the reset does not act on E119. Note the date so you know how long the fill lasts.

Get a Gas Safe registered engineer to look at your Potterton E119

We do not pass enquiries to a repair firm, so there is no form here. Find a Gas Safe registered engineer through the Gas Safe Register, and ask to see their registration card when they arrive — it is the register, not the van, that tells you they are qualified.

What it costs to fix

Typical repair cost

£0–£300

Time on site

10 minutes

Nothing to top up. Water pressure switch replaced £110–£170. Expansion vessel recharge £80–£120, replacement £180–£300. Leak trace from £90.

Typical UK prices including parts and labour, updated September 2026. Your quote may differ.

Parts you may need

We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.

Expansion vessel (8 litre, sealed system)

EV-8L£35–£85Plumbing merchant

Price checked 28 September 2026

Pressure relief valve, 3 bar

PRV-3B£18–£42Plumbing merchant

Price checked 28 September 2026

Baxi / Potterton / Main hydraulic pressure switch (600, 800, Assure, Eco Compact)

5114748£40–£90Authorised Baxi parts distributor

Price checked 28 September 2026

Own this appliance and had this code? . Nothing is published until a person has read it.

Common questions about Potterton E119

The display flashes E1 and then 19. Is that two faults?

One. The window shows two characters, so Potterton split the code: "code E133 will be displayed by 'E1' alternating with '33'" is the example in the user guide, and E119 follows the same pattern.

My Potterton Assure shows 118, not E119. Same thing?

Same fault — the primary circuit below half a bar — but a different generation with a different display. The Assure and Promax Ultra pages for 118 apply to you.

I cannot find a filling loop under the boiler.

On a Promax the loop is two blue-handled taps with a separate pipe that the installer may have taken away or left in the cupboard. If there are no taps under the boiler, the loop is on the pipework nearby; if there is nothing at all, an engineer will need to bring one.

Written by

Andrew Pickett

Researcher and writer

Last updated

Technical review

Not reviewed by an engineer

No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.

What we check instead

Sources and how we verified this

We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.

  • Manufacturer technical and service documentation

This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.

Read our full verification process

Was this page helpful?