This fault can involve incomplete combustion and carbon monoxide.
If anyone in the property feels sick, dizzy or drowsy, or you can smell gas: open the windows, leave the building, and do not switch anything on or off. Then call the National Gas Emergency Service.
0800 111 999Potterton E128 fault codewhat it means and how to fix it
Flame failure during normal operation on the Potterton Assure and Promax Ultra: the burner was lit and went out. Resettable; recurring E128 wants an engineer.
Take care
How long does the burner run before 128?
The right answer depends on what you can see. Pick the one that matches.
Choose the option on the left that matches what your appliance is doing, and the answer for that case appears here.
A few seconds after lighting
Flame detection: electrode or earth.
Engineer; a modest part.
Minutes into a run, often at full output
Gas supply pressure or flue disturbance.
Engineer with a manometer at the meter; the fix may be outside the boiler.
Only in wind or rain
Flue terminal position or a damaged seal.
Flue inspection. Do not ignore it; recirculation affects combustion.
What E128 means
This is the digital-display generation's code for a flame that was established and then lost, as distinct from one that never lit. The Assure System and Promax Ultra installation manuals separate the two in the same paragraph: 133, 134 and 135 cover a gas supply that was interrupted, an ignition that failed or a flame that was never detected, while 128 is reserved for a flame that was lost once the boiler was already running normally.
The table entry is simply "Flame failure", it carries the R symbol, and it is on both manuals' list of codes that a one-to-three-second press of the Reset button will clear. It is not on the older Promax and Titanium tables; those boilers report a lost flame as E133 whatever stage it happened at, so an owner used to a Promax will not have seen this number before. The fault-finding chart in the Assure System manual reaches 128 at the step "Burner goes out after 5 seconds" and sends the engineer to section G, which is the flame-sensing side: electrode condition, its connection, and the earth.
If the burner lit and ran for minutes before dropping out, the causes move to the gas supply (pressure falling under load, a regulator on its way out), the flue (recirculation on a windy day), or a condensate pipe that is filling up faster than it drains.
What causes it
| Cause | What is actually happening | How likely |
|---|---|---|
| Flame sensing electrode | The Assure uses one combined "detection / spark ignition electrode" (part 7686344). Worn or cracked, it reports a flame that is there as missing and the boiler shuts down to protect itself. | Common |
| Gas pressure falling when the burner is running | The Assure installer manual asks for a minimum 19 mbar at the meter. A supply that is fine at rest and low under load produces a flame that lifts off and dies at full rate. | Occasional |
| Flue recirculation or condensate backing up | Products of combustion drawn back into the air intake, or a condensate trap that cannot drain, both disturb a running flame. Both are also things a service should catch. | Occasional |
| Earth or wiring to the burner | Flame detection relies on a good earth path. The Assure Heat manual's ignition-fault remedy begins with "check earthing of the appliance", and the same applies here. | Rare |
What to try yourself
Check other gas appliances still work, and in cold weather check any external condensate pipe for ice.
Press Reset for about one second. Holding it longer than two seconds will not reset an Assure, according to its user guide.
If 128 comes back within the day, note the time and what the weather was doing, and contact your installer or Baxi Customer Support. Do not keep resetting it.
Get a Gas Safe registered engineer to look at your Potterton E128
We do not pass enquiries to a repair firm, so there is no form here. Find a Gas Safe registered engineer through the Gas Safe Register, and ask to see their registration card when they arrive — it is the register, not the van, that tells you they are qualified.
What it costs to fix
Typical repair cost
£0–£250
Time on site
5 minutes
Free if a reset holds. Electrode £80–£150 fitted. Gas pressure fault at the meter is the supplier's. Flue seal or terminal work £120–£250.
Typical UK prices including parts and labour, updated September 2026. Your quote may differ.
Parts you may need
We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.
Baxi / Potterton / Main detection and spark ignition electrode
7686344£25–£60Authorised Baxi parts distributor
Price checked 28 September 2026
Baxi / Potterton / Main gas valve
7683968£120–£240Authorised Baxi parts distributor
Price checked 28 September 2026
Own this appliance and had this code? . Nothing is published until a person has read it.
Related Potterton fault codes
- E133Get it checkedGas supply interrupted, ignition failed or no flame detected — every Potterton generation. Confirm the gas supply, one reset (5 s on the knob, 1–3 s on the button), and call if it returns.Related: ignition and gas supply
- E135Get it checkedThe Assure and Promax Ultra's internal-error ignition code: the control blames its own side of the gas valve rather than the supply for the flame that never came. One reset; then an engineer.Related: ignition and gas supply
- E09Get it checkedThe Assure and Promax Ultra's gas valve connection cable fault: the board has lost its wiring link to the valve. Resettable once; recurring 09 is a wiring or PCB job.Related: ignition and gas supply
- Red light flashingGet it checkedPotterton Assure Heat, Titanium Heat and Ultra Heat have no display: the illuminated button flashes red a number of times when the boiler has locked out. The count is the code.Related: ignition and gas supply
- E15Get it checkedThe Assure and Promax Ultra's own-valve code: the board has detected a fault in the gas valve itself, not its cable. One reset allowed; then an engineer with a meter.Related: ignition and gas supply
- E384Get it checkedThe Assure and Promax Ultra report a flame signal while the gas valve is shut. An electrode or PCB fault, and the Assure manual's answer is to go over the board.Related: ignition and gas supply
Own a Potterton boiler? Save it and its codes come first next time.
Related guides
Technical review
Not reviewed by an engineer
No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.
Sources and how we verified this
We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.
- Manufacturer technical and service documentation
This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.