The flame was established and then repeatedly lost. That is a different fault from failing to light and it points somewhere else.

Take care

Some of this is safe to check yourself, but the repair itself is not. If the fault comes back after one reset, stop resetting it and get a Gas Safe registered engineer to look at the Potterton properly.

What E128 means

E128 is loss of flame, logged when the appliance lights successfully and then loses the flame signal during operation. Potterton documentation describes it as flame failure occurring repeatedly — some sources give twelve occurrences as the threshold before it latches. The distinction from an ignition lockout is the useful part. If the burner lit, then the electrode sparked well enough, gas arrived, and the valve opened. Something interrupted a flame that was already burning. In practice there are four realistic explanations: the gas supply sags under load rather than being absent, condensate backs up shortly after firing, the flue recirculates its own products once warm, or the sensing electrode loses a marginal signal as the combustion chamber heats up and components expand. Wind across an exposed flue terminal belongs on the list too, and on the flats and end-terrace properties where Promax appliances often sit, exposed terminals are not unusual.

What causes it

Causes of the Potterton E128 fault code, most common first
CauseWhat is actually happeningHow likely
Sensing electrode at the end of its lifeOn a Promax that has never had one replaced, this is the front-runner by some distance. It reads well enough cold and drifts below threshold as the chamber warms, which is why the fault is intermittent long before it becomes permanent.Common
Condensate trap silted after years of serviceQuite distinct from a frozen pipe, and not seasonal at all. A decade of acidic condensate leaves the internal trap partly obstructed, so it floods back a couple of minutes into every firing whatever the weather.Common
Gas supply that will not hold at full rateOften surfaces after a range cooker or a gas fire has been added to a supply that was already marginal. The boiler lights, then loses out to the competition.Occasional
Exposed flue terminalPromax appliances went into a great many flats and end terraces where the terminal sits high and unsheltered. Wind across it can lift the flame clear of the burner.Occasional

What to try yourself

  1. Keep a short log over a few days: what time it failed, what else was running in the house, and what the weather was doing. E128 is a pattern fault, and the pattern is most of the diagnosis.

  2. Pay particular attention to whether it drops out at the same point every single time. A stopwatch-consistent failure two or three minutes in is the signature of condensate backing up internally.

  3. Run it once with every other gas appliance off, then once with the hob going flat out. A clear difference between those two tells an engineer to arrive with a manometer.

  4. Hand the log over when somebody attends. An intermittent fault that refuses to perform on the day is the most expensive kind to chase, and your notes are what stops it taking three visits.

Get a Gas Safe registered engineer to look at your Potterton E128

Gas Safe Register engineers only. No obligation.

What it costs to fix

Typical repair cost

£90–£450

Time on site

25 minutes

Clearing a condensate blockage is £80 to £150. An electrode is £110 to £190 fitted. Gas supply pipework corrections range from £150 to over £600 depending on what has to be replaced.

Typical UK prices including parts and labour, updated August 2026. Your quote may differ.

Parts you may need

We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.

Condensate trap and siphon

COND-TRAP£15–£38Plumbing merchant

Price checked 5 August 2026

What other owners found

Nobody has shared what worked for them on this code yet. If you have had it, you would be the first — and it genuinely helps the next person.

Written by

Fault Code Check editorial team

Updated

Reviewed by

Technical reviewer

Gas Safe registration to be displayed on appointment

Last reviewed

Sources and how we verified this

We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.

  • Manufacturer technical and service documentation
  • Interviews with working engineers

Checked by Technical reviewer (Gas Safe registration to be displayed on appointment) on 5 August 2026.

Read our full verification process