Potterton E40 fault codewhat it means and how to fix it

Get it checkedBoilerDigital display, flashing 40 with a spanner: Potterton Assure Combi and System (2019–2023), Promax Ultra Combi (2015–2019). No equivalent on the rotary-switch ranges.Last updated

Central heating return NTC fault on the Potterton Assure and Promax Ultra. The return sensor is open or short. Shown with a spanner; engineer.

Take care

Some of this is safe to check yourself, but the repair itself is not. If the fault comes back after one reset, stop resetting it and get a Gas Safe registered engineer to look at the Potterton properly.

Get a Gas Safe registered engineer to look at your Potterton E40

We do not pass enquiries to a repair firm, so there is no form here. Find a Gas Safe registered engineer through the Gas Safe Register, and ask to see their registration card when they arrive — it is the register, not the van, that tells you they are qualified.

What E40 means

The digital-display Pottertons carry a sensor the rotary-switch ranges never had: a return NTC on the water coming back from the radiators, which lets the board compare flow and return (the 154 test) and modulate more finely. Code 40 is that sensor failing open or short — "Central heating return NTC fault" in the Assure and Promax Ultra tables, in the group the installation manual introduces as "followed by 20, 28, 40, 160 or 321 indicates possible faulty components". It is displayed with the spanner symbol, which the Assure user guide explains: "The spanner symbol appears it cannot be reset by the user. Please contact your Installer, Annual Service Provider or Baxi Customer Support."

The fault-finding chart takes "20, 28, 40 or 321 flashing" to section A, the sensor checks. Practically this is E20's twin. The two heating sensors are supplied as one spare on the Assure — "Flow sensor and return sensor" 7207471 — and the same lead and connector faults apply. There is nothing for the owner to do but report it, and no reset to try.

What causes it

Causes of the Potterton E40 fault code, most common first
CauseWhat is actually happeningHow likely
Connector or lead to the return sensorLoose plug or damaged lead reads as open circuit. First check.Common
Return thermistor out of rangeTested against the flow sensor and the 10 kΩ at 25 °C figure; replaced as the pair.Common
PCB inputRare; after a new sensor still shows 40.Rare

Can you fix it yourself?

What it costs to fix

Typical repair cost

£50–£120

Time on site

30 minutes

Sensor pair and fitting £60–£110.

Typical UK prices including parts and labour, updated September 2026. Your quote may differ.

Parts you may need

We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.

Baxi / Potterton / Main NTC temperature sensor (flow, return or DHW)

7207471£18–£45Authorised Baxi parts distributor

Price checked 28 September 2026

Own this appliance and had this code? . Nothing is published until a person has read it.

Written by

Andrew Pickett

Researcher and writer

Last updated

Technical review

Not reviewed by an engineer

No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.

What we check instead

Sources and how we verified this

We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.

  • Manufacturer technical and service documentation

This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.

Read our full verification process

Was this page helpful?