Skip to content
FaultcodeCheck

Potterton E20 fault codewhat it means and how to fix it

Get it checkedBoilerAll Potterton code displays. Rotary knob and two-character window, shown as E then 20: Promax Combi, System and Store, Titanium Combi, Gold Combi and System, Heatmax (2007–2019). Digital display, flashing 20 with a spanner: Assure Combi and System (2019–2023), Promax Ultra (2015–2019).Last updated

Central heating NTC fault on every Potterton code display — the flow temperature sensor is open or short circuit. The user guide says note the code and call; no reset is offered.

Take care

Some of this is safe to check yourself, but the repair itself is not. If the fault comes back after one reset, stop resetting it and get a Gas Safe registered engineer to look at the Potterton properly.

Get a Gas Safe registered engineer to look at your Potterton E20

We do not pass enquiries to a repair firm, so there is no form here. Find a Gas Safe registered engineer through the Gas Safe Register, and ask to see their registration card when they arrive — it is the register, not the van, that tells you they are qualified.

Does the boiler still make hot water?

The right answer depends on what you can see. Pick the one that matches.

Choose the option on the left that matches what your appliance is doing, and the answer for that case appears here.

Yes, but no heating

Consistent with the heating flow sensor alone.

Engineer; a short visit.

Nothing works

The sensor is in the common flow path; expected.

Engineer.

What E20 means

E20 opens every Potterton table from the 2007 Gold Combi HE to the 2019 Assure: "Central Heating NTC Fault". The NTC is the thermistor that reads the heating flow temperature, and the boiler stops when its reading is impossible — open circuit or short.

Potterton's user guides file E20 with E28, E50, E125 and E160 as the component faults, where the owner's only job is to write the code down and ring the installer. The installation manuals confirm it is a component code, and fault-finding section E gives the bench test: a sound sensor reads roughly 10 kΩ when cold at 25 °C and its resistance falls as it warms, so anything wildly off that curve is replaced.

On the Assure and Promax Ultra the number is 20, it is shown with the spanner rather than the R — the installer manuals say "followed by 20, 28, 40, 160 or 321 indicates possible faulty components" — and it is not on the reset list. The sensor is cheap and the job is short; the reason it fails is usually a connector or a lead rather than the thermistor itself, which is why a good engineer checks the plug before fitting a part.

What causes it

Causes of the Potterton E20 fault code, most common first
CauseWhat is actually happeningHow likely
Sensor lead or connectorA plug off or corroded at the sensor or the PCB reads as open circuit. First check on the chart, and the most common finding.Common
Thermistor failedOut of range against the 10 kΩ at 25 °C figure. On the Assure the flow and return sensors are one spare (7207471); on the Promax, "NTC Sensor" 5114725.Common
PCB inputRare; suspected only when a new sensor and a good lead still show E20.Rare

Can you fix it yourself?

What it costs to fix

Typical repair cost

£50–£120

Time on site

30 minutes

Sensor and fitting £60–£110. Connector repair at a call-out £60–£90.

Typical UK prices including parts and labour, updated September 2026. Your quote may differ.

Parts you may need

We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.

Baxi / Potterton / Main NTC temperature sensor (flow, return or DHW)

7207471£18–£45Authorised Baxi parts distributor

Price checked 28 September 2026

Own this appliance and had this code? . Nothing is published until a person has read it.

Written by

Andrew Pickett

Researcher and writer

Last updated

Technical review

Not reviewed by an engineer

No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.

What we check instead

Sources and how we verified this

We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.

  • Manufacturer technical and service documentation

This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.

Read our full verification process

Was this page helpful?