Potterton E28 fault codewhat it means and how to fix it

Get it checkedBoilerRotary knob and two-character window, shown as E then 28: Gold Combi HE (2007, "Incorrect PCB Fitted"); Promax Combi HE Plus and HE A, Promax System HE Plus and HE A, Gold HE A, Titanium Combi 2012, Heatmax, Promax Store ("Flue NTC Fault"); Promax Combi 2015–19, Titanium Combi 2015–17, Promax System 2016–19, Gold Combi and System 2016–19 (flue NTC, air pressure switch, blocked flue or condensate). Digital display, flashing 28 with a spanner: Assure Combi and System, Promax Ultra ("Flue NTC fault").Last updated

Three meanings on Potterton: incorrect PCB fitted (Gold Combi HE 2007), flue NTC fault (2008–2014 and all digital displays), or flue NTC, air pressure switch, blocked flue or condensate (2015–2019 combis).

Take care

Some of this is safe to check yourself, but the repair itself is not. If the fault comes back after one reset, stop resetting it and get a Gas Safe registered engineer to look at the Potterton properly.

Which Potterton and which year?

The right answer depends on what you can see. Pick the one that matches.

Choose the option on the left that matches what your appliance is doing, and the answer for that case appears here.

Gold Combi HE, 2007–2009

"Incorrect PCB Fitted". A board-configuration fault.

Engineer; usually follows board work.

Promax or Gold HE Plus / HE A, Titanium 2012, Heatmax, or any Assure / Promax Ultra

Flue temperature sensor or its lead.

Engineer; note the code as the user guide says.

Promax Combi 2015+, Titanium 2015+, Promax System 2016+, Gold Combi/System 2016+

Sensor, switch, blocked flue or blocked condensate.

Check the condensate pipe in frost; otherwise engineer, and mention the flue.

What E28 means

No other Potterton code has changed meaning as often, and the year of the boiler decides which one you have. The 2007 Gold Combi HE installation instructions list E28 as "Incorrect PCB Fitted" — a board check, nothing to do with the flue. From the 2008 Promax Combi HE Plus through the 2010–2014 HE A ranges and the 2012 Titanium it is "Flue NTC Fault", the flue temperature sensor open or short circuit, in the group the user guide says to "make a note of ... and contact your installer or service engineer".

Then the 2015 Promax Combi, 2015 Titanium Combi, 2016 Promax System and 2016–17 Gold Combi and System gained an air pressure switch, and the row became "Flue NTC Fault, Air Pressure Switch Fault, Blocked Flue, Blocked Condensate or Wiring Fault", with a new sentence in the user guide: "E28 may also indicate a blocked flue or condensate drain."

The installation manuals for those ranges add a test — apply light suction to the switch's negative spigot and "Error Code E28 should display whilst suction is applied" — and the fault-finding section E now ends with "Flue blocked or damaged: Unblock or repair flue. Condensate trap or pipework blocked: Unblock." The Assure and Promax Ultra dropped the switch again; their 28 is "Flue NTC fault" only, with a spanner and no reset. For the owner of a 2015-or-later rotary-switch combi, E28 in freezing weather is worth a look at the condensate pipe before anyone is called. For everyone else it is a sensor or a board and an engineer's visit.

What causes it

Causes of the Potterton E28 fault code, most common first
CauseWhat is actually happeningHow likely
Flue NTC sensor or its lead (all ranges from 2008)Section E of the chart: cold resistance about 20 kΩ at 25 °C for the flue sensor, falling as it warms; out of range, replace it. The connector at the sensor is the first thing to reseat.Common
Condensate pipe blocked or frozen (2015–2019 combis)Back-pressure in the flue operates the air pressure switch. External condensate runs in cold weather are the usual reason; the user guide names "a blocked flue or condensate drain" for E28.Common
Air pressure switch or its tube (2015–2019 combis)The switch reads the negative pressure at the venturi through a small tube. A split tube, a switch stuck open, or the wiring between it and the board give E28 with a clear flue.Occasional
Flue blocked, damaged or recirculating (2015–2019 combis)The reason the switch exists. Debris at the terminal, a crushed flue, or a seal failure. This is a combustion safety fault and the boiler is right to stop.Occasional
Wrong or unconfigured PCB (Gold Combi HE 2007)The 2007 table's only meaning. Seen after a board replacement with the wrong part or an unset output.Rare

What to try yourself

  1. Find the year and range on the data badge or the user guide. If it is a 2015-or-later Promax Combi, Titanium Combi, Promax System or Gold with the rotary knob, continue; otherwise E28 is a sensor or board fault and the user guide's instruction is to note it and call.

  2. In cold weather, check any external condensate pipe for ice and thaw it with warm water. Check the flue terminal outside is not obstructed by leaves, a nest or snow.

  3. Potterton offer no reset for E28. Switch the boiler off at the spur for a minute and back on; if the flue or condensate was the cause it will run. If E28 returns, contact your installer or Baxi Customer Support and say which range you have.

    A blocked or damaged flue is a carbon monoxide risk. Do not try to clear anything but a frozen condensate pipe, and make sure there is a working CO alarm in the room.

Get a Gas Safe registered engineer to look at your Potterton E28

We do not pass enquiries to a repair firm, so there is no form here. Find a Gas Safe registered engineer through the Gas Safe Register, and ask to see their registration card when they arrive — it is the register, not the van, that tells you they are qualified.

What it costs to fix

Typical repair cost

£0–£300

Time on site

15 minutes

Free if a frozen condensate pipe was the cause. Flue NTC £70–£130 fitted. Air pressure switch £90–£160. Condensate re-route £120–£250. Flue repair varies.

Typical UK prices including parts and labour, updated September 2026. Your quote may differ.

Parts you may need

We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.

Condensate trap and siphon

COND-TRAP£15–£38Plumbing merchant

Price checked 28 September 2026

Baxi / Potterton / Main flue NTC sensor

7207892£22–£50Authorised Baxi parts distributor

Price checked 28 September 2026

Baxi Platinum / Potterton air pressure switch

£35–£80Authorised Baxi parts distributor

Price checked 28 September 2026

Own this appliance and had this code? . Nothing is published until a person has read it.

Own a Potterton boiler? Save it and its codes come first next time.

Written by

Andrew Pickett

Researcher and writer

Last updated

Technical review

Not reviewed by an engineer

No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.

What we check instead

Sources and how we verified this

We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.

  • Manufacturer technical and service documentation

This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.