Viessmann A9 fault codewhat it means and how to fix it

Get it checkedBoilerVitodens rangeLast reviewed

The condensate drain is blocked and cannot flow freely. Worth checking the external pipe before you call anyone.

Take care

Some of this is safe to check yourself, but the repair itself is not. If the fault comes back after one reset, stop resetting it and get a Gas Safe registered engineer to look at the Viessmann properly.

What A9 means

A9 on a Vitodens indicates the condensate drain is blocked or cannot flow away. A condensing boiler produces a genuinely surprising volume of water — several litres a day in cold weather — and it is mildly acidic, typically around pH 3 to 4. It has to go somewhere. When the drain blocks, condensate backs up inside the appliance, and Viessmann shut the boiler down before it reaches anything it should not. Viessmann literature also associates A9 with a group of codes where the appliance cools down because sensor inputs are not being read correctly, so on some models it can present alongside sensor-related behaviour. The most common cause by far, and the one you can address yourself, is the external condensate pipe freezing. Beyond that the internal trap can silt up over years of service, and that one does need an engineer since it sits inside the case.

What causes it

Causes of the Viessmann A9 fault code, most common first
CauseWhat is actually happeningHow likely
External condensate pipe frozenBy far the most common cause and the only one you can resolve yourself. Dominates during any cold snap.Common
Condensate trap silted internallyYears of acidic condensate leave deposit in the trap until it stops draining. Produces the same symptom regardless of weather.Occasional
Discharge point blockedThe gully or drain the pipe discharges into is itself blocked with leaves or debris, so the condensate has nowhere to go.Occasional
Pipe run with inadequate fallA long horizontal run without enough slope holds water permanently and freezes readily. An installation issue rather than a fault, and it recurs every winter until corrected.Occasional

What to try yourself

  1. Go outside and find the condensate pipe — plastic, usually white or grey, running from the appliance towards a drain. Follow its whole length rather than just the section near the boiler.

  2. Feel along it for a rigid, ice-cold section. Bends, the lowest point of a horizontal run, and the open end are where ice forms first.

  3. Pour hand-hot water slowly along the frozen section, working from the open end back towards the appliance so the meltwater has somewhere to escape.

    Never boiling water and never a heat gun or naked flame. Cold plastic cracks readily and a split condensate pipe is a far worse position to be in.
  4. Check where the pipe discharges. If it goes into an outside gully, clear any leaves or debris blocking it.

  5. Press the reset button and call for heat. If it runs, lag the external pipe before the next cold spell — and if it freezes every year, ask about upsizing or rerouting it rather than accepting it as normal.

Get a Gas Safe registered engineer to look at your Viessmann A9

Gas Safe Register engineers only. No obligation.

What it costs to fix

Typical repair cost

£0–£280

Time on site

25 minutes

Free if you thaw the pipe yourself. Clearing a silted trap is £90 to £180. Lagging, upsizing or rerouting an external run is £120 to £280.

Typical UK prices including parts and labour, updated August 2026. Your quote may differ.

Parts you may need

We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.

Condensate trap and siphon

COND-TRAP£15–£38Plumbing merchant

Price checked 5 August 2026

What other owners found

Nobody has shared what worked for them on this code yet. If you have had it, you would be the first — and it genuinely helps the next person.

Common questions about Viessmann A9

The weather is mild and I still have A9. What now?

Freezing is ruled out, so the likely candidates are a silted internal trap or a blocked discharge point. Check the outside gully first since that is free, and if it is clear then the trap needs an engineer — it is inside the case.

Is the condensate harmful?

It is mildly acidic, roughly comparable to vinegar, so it will irritate skin and mark flooring over time but it is not dangerous in small quantities. Rinse it off if you get any on you and mop up any that has escaped.

It freezes every single winter. Is that just how condensing boilers are?

No, and it is worth pushing back. A pipe that freezes annually is undersized, poorly fallen, or unlagged. Guidance on external condensate runs has tightened considerably and a competent installer can usually put it right.

Written by

Fault Code Check editorial team

Updated

Reviewed by

Technical reviewer

Gas Safe registration to be displayed on appointment

Last reviewed

Sources and how we verified this

We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.

  • Manufacturer technical and service documentation
  • Trade body guidance

Checked by Technical reviewer (Gas Safe registration to be displayed on appointment) on 5 August 2026.

Read our full verification process