Viessmann F.65 fault codewhat it means and how to fix it

Stop — call an engineerBoilerF.65: Vitodens 100-W B1HF/B1KF, B1HG/B1KG; 111-W B1LF, B1LG. F.361 and F.379: those units plus 100-W B1GA and 050-W B0HA/B0KALast updated

No flame signal at burner start on a 2020-on Vitodens — the numeric table's equivalent of F4. Burner locked out. Check the gas is on, reset once; if it returns, call a Gas Safe engineer.

Get a Gas Safe registered engineer to look at your Viessmann F.65

We do not pass enquiries to a repair firm, so there is no form here. Find a Gas Safe registered engineer through the Gas Safe Register, and ask to see their registration card when they arrive — it is the register, not the van, that tells you they are qualified.

What F.65 means

Three rows in the numeric table say the burner tried to light and the ionisation electrode saw nothing. F.65 — "Burner in a fault state — Flame signal not present or insufficient at burner start" — is in the 100-W B1HF/B1KF and B1HG/B1KG tables and the 111-W B1LF/B1LG, but not in the B1GA or the 050-W B0HA/B0KA, whose tables carry only F.361 with the same words: "Flame signal is not present or insufficient at burner start." F.379, "Flame signal not present or insufficient", is on every unit and is the same failure without the qualifier. All three lock the burner out. The measures for F.65 are the long list: gas supply (pressure and gas flow switch), gas solenoid valve, condensate backup and the condensate drain, then the ionisation electrode and its cable, the ignition and its module, and the ignition electrode's distance, contamination and insulation, ending "Reset the appliance." F.361's measures are shorter and point at the electrode and its connections, with a note that "deposits on the electrodes indicate foreign bodies in the combustion air" — laundry detergents, cleaning agents, toiletries or a dusty air supply — which is Viessmann telling the contractor to look at the room the boiler is in, not just the boiler.

For the householder the operating instructions give the same short list they give for any flashing fault code with a burner that will not start: with natural gas, that the gas shut-off valve is open (and if necessary check with your gas supply utility); with LPG, that there is fuel; then "Reset the burner" once, by showing the fault number with the arrow keys and holding up and down together for about four seconds until the rotating bar appears. If the code recurs, notify the heating contractor and do not reset again — Viessmann's warning that unrectified faults can have life threatening consequences is printed beside that instruction. The electrode that proves the flame on these boilers is a wear part, and the condensate trap that backs up into the heat cell in a cold snap is the seasonal cause; both are in the row.

What causes it

Causes of the Viessmann F.65 fault code, most common first
CauseWhat is actually happeningHow likely
Gas not reaching the burnerA closed shut-off valve, an empty prepayment meter or LPG cylinder, or a supply interruption. Viessmann's first measure, and the only cause the householder can clear.Common
Ionisation electrode worn or contaminatedThe flame may be there and unseen. Deposits on the electrode are Viessmann's clue to contaminated combustion air; the electrode and its cable are named in all three rows.Common
Condensate backed up into the heat cellNamed in the F.65 measures. A blocked or frozen condensate drain floods the bottom of the heat exchanger and the burner cannot light through it. F.176 and F.540 are the same cause caught by other means.Common
Ignition electrode or ignition moduleNo spark, a weak one, or cracked insulation earthing it. In the F.65 list; when the control unit can tell there was no spark at all it shows F.359 instead.Occasional
Gas solenoid valve or gas pressureA gas train that does not open, or inlet pressure below the type-plate figure under load. Contractor measurements.Occasional

Can you fix it yourself?

What it costs to fix

Typical repair cost

£80–£320

Time on site

1h 30m

An electrode and a visit at the low end; a gas train at the top. A closed gas valve costs nothing but the call-out if one was booked.

Typical UK prices including parts and labour, updated September 2026. Your quote may differ.

Parts you may need

We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.

Viessmann ionisation (flame-monitoring) electrode

£20–£55Authorised Viessmann parts distributor

Price checked 28 September 2026

Viessmann ignition electrode set

£25–£65Authorised Viessmann parts distributor

Price checked 28 September 2026

Viessmann ignition module (ignition unit)

£60–£140Authorised Viessmann parts distributor

Price checked 28 September 2026

Viessmann gas train (gas valve assembly)

£150–£320Authorised Viessmann parts distributor

Price checked 28 September 2026

Viessmann condensate trap (siphon)

£25–£70Authorised Viessmann parts distributor

Price checked 28 September 2026

Own this appliance and had this code? . Nothing is published until a person has read it.

Own a Viessmann boiler? Save it and its codes come first next time.

Written by

Andrew Pickett

Researcher and writer

Last updated

Technical review

Not reviewed by an engineer

No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.

What we check instead

Sources and how we verified this

We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.

  • Manufacturer technical and service documentation

This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.

Read our full verification process

Was this page helpful?