Skip to content
FaultcodeCheck

Viessmann F.357 fault codewhat it means and how to fix it

Get it checkedBoilerF.357: Vitodens 100-W B1HF/B1KF, B1HG/B1KG; 111-W B1LF, B1LG. F.353, F.467, F.383, F.384: those units plus 100-W B1GA and 050-W B0HA/B0KALast updated

Insufficient gas supply on a 2020-on Vitodens. F.353 is the softer version with output reduced; F.467, F.383 and F.384 blame calibration or a contaminated gas line. Check the gas is on, then call an engineer.

Take care

Some of this is safe to check yourself, but the repair itself is not. If the fault comes back after one reset, stop resetting it and get a Gas Safe registered engineer to look at the Viessmann properly.

Get a Gas Safe registered engineer to look at your Viessmann F.357

We do not pass enquiries to a repair firm, so there is no form here. Find a Gas Safe registered engineer through the Gas Safe Register, and ask to see their registration card when they arrive — it is the register, not the van, that tells you they are qualified.

What F.357 means

The numeric table has a family of gas-starvation rows. F.357 — "Burner in a fault state — Insufficient gas supply" — is on the 100-W B1HF/B1KF and B1HG/B1KG and the 111-W B1LF/B1LG (the B1GA and 050-W B0HA/B0KA tables omit it). F.353, on every unit, is the graceful version: "Shutdown with restart if demand exists — Insufficient gas supply, burner output reduced", meaning the boiler has throttled itself and will try again. F.467 is "Gas supply insufficient during calibration. Contaminated or insufficiently sized gas line", and F.383/F.384 are "Possible contamination of gas line". All are a burner that could not get the gas it asked for. F.357's measures are the most complete: "Check that the main gas valve and the gas shut-off valve are open. Test static gas pressure and gas flow pressure. Check that on-site gas line and gas flow switch are correctly sized." Then a note only an installer would write: if the building's pressure regulator leaks, pressure creeps up while the burner is idle and the gas flow switch may trip on restart. Then the coil resistance at the fuel valve (approx. 4 kΩ), the cable to the fan unit, the ignition electrode's insulation, and "Reset the appliance."

Two things the householder can do are in the operating instructions under "No fuel": with natural gas, "Open the gas shut-off valve. If necessary, check with your gas supply utility"; with LPG, "Check the fuel reserves and re-order if required." A prepayment meter out of credit, a supplier interruption or a gas valve nudged shut are the innocent causes and the only ones you can clear. Everything else — working pressure measured at the boiler under full load, a strainer in the gas solenoid valve blocked with debris from brazed pipework (F.467's note), a supply pipe too small for a 32 kW appliance — is Gas Safe work, and a gas-line contamination row should not be reset repeatedly in the hope it clears.

What causes it

Causes of the Viessmann F.357 fault code, most common first
CauseWhat is actually happeningHow likely
Gas shut off or supply interruptedA valve nudged closed, no credit on a prepayment meter, an LPG tank run down, or a network interruption. Viessmann's first measure and the householder's check.Common
Working pressure too low under loadStatic pressure fine, flow pressure collapsing when the burner opens up. A regulator, meter or undersized pipe run; measured by the contractor.Common
Gas solenoid valve strainer contaminatedDebris from installation or brazing blocking the inlet strainer. Named in the F.467 note and the F.353 measures.Occasional
Gas line sized for a smaller applianceF.467's "insufficiently sized gas line". A replacement boiler on an old 15 mm run starves at full output.Occasional

Can you fix it yourself?

What it costs to fix

Typical repair cost

£0–£400

Time on site

1 hour

A closed valve or an empty meter costs nothing. Cleaning a strainer is a service visit; re-running an undersized gas supply is the top of the range.

Typical UK prices including parts and labour, updated September 2026. Your quote may differ.

Parts you may need

We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.

Viessmann gas train (gas valve assembly)

£150–£320Authorised Viessmann parts distributor

Price checked 28 September 2026

Own this appliance and had this code? . Nothing is published until a person has read it.

Own a Viessmann boiler? Save it and its codes come first next time.

Written by

Andrew Pickett

Researcher and writer

Last updated

Technical review

Not reviewed by an engineer

No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.

What we check instead

Sources and how we verified this

We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.

  • Manufacturer technical and service documentation

This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.

Read our full verification process

Was this page helpful?