This fault can involve incomplete combustion and carbon monoxide.
If anyone in the property feels sick, dizzy or drowsy, or you can smell gas: open the windows, leave the building, and do not switch anything on or off. Then call the National Gas Emergency Service.
0800 111 999Viessmann F.381 fault codewhat it means and how to fix it
Flame lost while the burner was running on a 2020-on Vitodens and it has locked out; F.378 is the same event. The gas supply, flue and ionisation electrode are for a Gas Safe engineer.
Stop — this needs an engineer
Get a Gas Safe registered engineer to look at your Viessmann F.381
We do not pass enquiries to a repair firm, so there is no form here. Find a Gas Safe registered engineer through the Gas Safe Register, and ask to see their registration card when they arrive — it is the register, not the van, that tells you they are qualified.
What F.381 means
F.381 — "Burner in a fault state — Flame loss during operating phase" — and F.378 — "Flame loss during stabilisation or operating phase" — are the lockout rows for a flame that was established and then went out. The measures are the flame-loss set: "Check gas supply (gas pressure and gas flow switch). Check balanced flue system for flue gas recirculation. Check ionisation electrode, burner gauze assembly: clearance to burner gauze assembly, contamination on electrode. Reset the appliance." The F.378 row phrases the middle item as "Check flue gas recirculation" and "Check for contamination of ionisation electrode and burner gauze assembly", which is the same instruction. The numeric table has a third row with the F.378 wording, F.64, whose system characteristic is "Normal operation; burner restarts" — so the same words can be a message or a fault depending on the number, and the number is what to write down.
Why a running burner loses its flame is a shorter list than why one fails to light. Gas that drops away under load; combustion air contaminated with exhaust; an electrode whose signal was marginal and finally fell below the threshold; and, on a modulating burner, a mixture at the low end of its range that a gust down the flue can blow out. Viessmann's combustion controller regulates the air ratio from the ionisation signal, so an electrode that is dirty or wrongly gapped does not just fail to see the flame, it steers the burner toward a mixture that is easier to lose. A flame that goes out repeatedly with the flue in good order is usually that electrode. The householder may reset once with the arrow keys after the burner has cooled and must notify the contractor if the fault recurs; nothing inside the case is user-serviceable.
What causes it
| Cause | What is actually happening | How likely |
|---|---|---|
| Ionisation electrode marginal | Worn, coated or wrongly gapped, it reads a weak signal and the controller both misjudges the mixture and loses the flame. The commonest repeat cause. | Common |
| Gas pressure falling under load | Other appliances starting, a regulator fault or a restricted supply. Viessmann's first measure. | Common |
| Flue gas recirculation or wind | Exhaust in the intake, or a terminal exposed to gusts that disturb a low-fire flame. Second in the row. | Occasional |
| Burner gauze assembly deteriorated | A damaged or fouled MatriX gauze gives an uneven flame front that lifts off at low output. Replaced with its insulation blocks. | Rare |
Can you fix it yourself?
Stop — this needs an engineer
What it costs to fix
Typical repair cost
£80–£320
Time on site
1h 30m
An electrode and visit at the low end; a burner gauze assembly or flue repair at the top.
Typical UK prices including parts and labour, updated September 2026. Your quote may differ.
Parts you may need
We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.
Viessmann ionisation (flame-monitoring) electrode
£20–£55Authorised Viessmann parts distributor
Price checked 28 September 2026
Viessmann gas train (gas valve assembly)
£150–£320Authorised Viessmann parts distributor
Price checked 28 September 2026
Viessmann MatriX burner gauze assembly with insulation blocks
£120–£300Authorised Viessmann parts distributor
Price checked 28 September 2026
Own this appliance and had this code? . Nothing is published until a person has read it.
Related Viessmann fault codes
- F4Stop — call an engineerNo flame signal was detected during burner start on any two-character Vitodens, so the burner has locked out. Reset once; if it returns, call a Gas Safe engineer.Related: ignition and gas supply
- F.65Stop — call an engineerNo flame signal at burner start on a 2020-on Vitodens — the numeric table's equivalent of F4. Burner locked out. Check the gas is on, reset once; if it returns, call a Gas Safe engineer.Related: ignition and gas supply
- F3Stop — call an engineerThe control unit saw a flame signal before it had opened the gas — a flame where there should be none, or a false signal from the ionisation electrode. Lockout; Gas Safe engineer.Related: ignition and gas supply
- E5Get it checkedViessmann call E5 an "internal fault" but their only instruction is to check the ionisation electrode and its cables — a flame-monitoring fault, blocked not locked, and one for a Gas Safe engineer.Related: ignition and gas supply
- F.357Get it checkedInsufficient gas supply on a 2020-on Vitodens. F.353 is the softer version with output reduced; F.467, F.383 and F.384 blame calibration or a contaminated gas line. Check the gas is on, then call an engineer.Related: ignition and gas supply
- F.359Stop — call an engineerNo ignition spark on a 2020-on Vitodens, so the burner locked out before it could light. Ignition electrode, ignition module or heat management unit: a Gas Safe engineer's diagnosis.Related: ignition and gas supply
Own a Viessmann boiler? Save it and its codes come first next time.
Related guides
Technical review
Not reviewed by an engineer
No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.
Sources and how we verified this
We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.
- Manufacturer technical and service documentation
This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.