Viessmann 51 fault codewhat it means and how to fix it
DHW outlet temperature sensor fault on a combi: 51 short circuit, 59 lead break. Heating continues but hot water stops, because the boiler cannot see the tap temperature it is controlling.
Before you start
Get a Gas Safe registered engineer to look at your Viessmann 51
We do not pass enquiries to a repair firm, so there is no form here. Find a Gas Safe registered engineer through the Gas Safe Register, and ask to see their registration card when they arrive — it is the register, not the van, that tells you they are qualified.
What 51 means
A Vitodens combi heats tap water through a plate heat exchanger and steers the burner by an outlet temperature sensor on the hot side of it. 51 is "No DHW heating — Short circuit, outlet temperature sensor" and 59 is "No DHW heating — Lead break, outlet temperature sensor", measure "Check the sensor", on the WB1A, WB1B, WB1C, B1HA/B1KA and B1HC/B1KC combis, the 111-W, the 050-W BPJD and the Vitotronic 200-W B2HB and 242-F B2UA. Without a plausible outlet reading the control unit will not run a hot-water cycle, so the symptom is a boiler that heats radiators normally and does nothing when a tap is opened; central heating is untouched. The WB1A table prints "short circuit" for both 51 and 59, which is a misprint carried in that edition — every later table gives 59 as the lead break.
Viessmann's repair note for this sensor is the reason the job is a contractor's: water can leak out when the outlet sensor is replaced, and the cold water shut-off valve must be closed and the DHW pipe and plate heat exchanger drained on the secondary side first. There is no householder step and no reset; the code clears itself when the sensor reads plausibly. On the 2020-on numeric-table units the pair is F.182 (short circuit) and F.183 (lead break), flagged "if installed"; a bare 59 on that display is F.59, mains undervoltage, which is unrelated and has its own page.
What causes it
| Cause | What is actually happening | How likely |
|---|---|---|
| Outlet sensor lead or plug | The sensor sits low in the boiler near the plate heat exchanger; its lead and plug are in the wet zone and suffer accordingly. 59. | Common |
| Sensor failed | Gone short (51) or open (59). Compared against the resistance curve and replaced with the secondary side drained. | Common |
| Scale on the sensor pocket | In hard-water areas scale on the DHW side can crack a sensor or its fitting over years. Often found with a plate heat exchanger that also needs descaling. | Occasional |
Can you fix it yourself?
Stop — this needs an engineer
What it costs to fix
Typical repair cost
£60–£140
Time on site
1 hour
A sensor plus draining the secondary side. Descaling the plate heat exchanger, if found, is extra.
Typical UK prices including parts and labour, updated September 2026. Your quote may differ.
Parts you may need
We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.
Viessmann DHW outlet temperature sensor
£15–£45Authorised Viessmann parts distributor
Price checked 28 September 2026
Own this appliance and had this code? . Nothing is published until a person has read it.
Related Viessmann fault codes
- 30Get it checkedBoiler water temperature sensor fault: 30 is a short circuit, 38 a lead break. The burner is blocked until the sensor reads plausibly again. Engineer replaces the sensor.Related: temperature sensors
- 50Usually simple to fixCylinder temperature sensor fault — 50 short circuit, 58 lead break. Heating continues; hot water from the cylinder stops until the sensor or its lead is replaced. Not a safety fault.Related: temperature sensors
- 10Usually simple to fixOutside temperature sensor fault — 10 short circuit, 18 lead break. The boiler keeps heating, in constant-temperature mode rather than weather-compensated. Not urgent; an engineer replaces the sensor.Related: temperature sensors
- 52Get it checkedFlow sensor fault on a 100-W combi: 52 is a short circuit, 5A a lead break. The burner is blocked, because the boiler cannot tell whether a tap is running. Engineer job.Related: temperature sensors
- F4Stop — call an engineerNo flame signal was detected during burner start on any two-character Vitodens, so the burner has locked out. Reset once; if it returns, call a Gas Safe engineer.Related: same brand
- F.74Get it checkedSystem pressure too low on a 2020-on Vitodens with the numeric display. The burner and pump stop until the pressure is back. Viessmann tell the householder to top up below 1.0 bar.Related: same brand
Own a Viessmann boiler? Save it and its codes come first next time.
Related guides
Technical review
Not reviewed by an engineer
No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.
Sources and how we verified this
We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.
- Manufacturer technical and service documentation
This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.