Viessmann 51 fault codewhat it means and how to fix it

Usually simple to fixBoilerCombis: Vitodens 100 WB1A, 100-W WB1A to B1HC/B1KC, 111-W B1LA to B1LD, 050-W BPJD; Vitotronic 200-W B2HB, 242-F B2UA. As F.182/F.183 on the 2020-on numeric-display unitsLast updated

DHW outlet temperature sensor fault on a combi: 51 short circuit, 59 lead break. Heating continues but hot water stops, because the boiler cannot see the tap temperature it is controlling.

Before you start

Some of this is safe to check yourself, but the repair itself is not. If the fault comes back after one reset, stop resetting it and get a Gas Safe registered engineer to look at the Viessmann properly.

Get a Gas Safe registered engineer to look at your Viessmann 51

We do not pass enquiries to a repair firm, so there is no form here. Find a Gas Safe registered engineer through the Gas Safe Register, and ask to see their registration card when they arrive — it is the register, not the van, that tells you they are qualified.

What 51 means

A Vitodens combi heats tap water through a plate heat exchanger and steers the burner by an outlet temperature sensor on the hot side of it. 51 is "No DHW heating — Short circuit, outlet temperature sensor" and 59 is "No DHW heating — Lead break, outlet temperature sensor", measure "Check the sensor", on the WB1A, WB1B, WB1C, B1HA/B1KA and B1HC/B1KC combis, the 111-W, the 050-W BPJD and the Vitotronic 200-W B2HB and 242-F B2UA. Without a plausible outlet reading the control unit will not run a hot-water cycle, so the symptom is a boiler that heats radiators normally and does nothing when a tap is opened; central heating is untouched. The WB1A table prints "short circuit" for both 51 and 59, which is a misprint carried in that edition — every later table gives 59 as the lead break.

Viessmann's repair note for this sensor is the reason the job is a contractor's: water can leak out when the outlet sensor is replaced, and the cold water shut-off valve must be closed and the DHW pipe and plate heat exchanger drained on the secondary side first. There is no householder step and no reset; the code clears itself when the sensor reads plausibly. On the 2020-on numeric-table units the pair is F.182 (short circuit) and F.183 (lead break), flagged "if installed"; a bare 59 on that display is F.59, mains undervoltage, which is unrelated and has its own page.

What causes it

Causes of the Viessmann 51 fault code, most common first
CauseWhat is actually happeningHow likely
Outlet sensor lead or plugThe sensor sits low in the boiler near the plate heat exchanger; its lead and plug are in the wet zone and suffer accordingly. 59.Common
Sensor failedGone short (51) or open (59). Compared against the resistance curve and replaced with the secondary side drained.Common
Scale on the sensor pocketIn hard-water areas scale on the DHW side can crack a sensor or its fitting over years. Often found with a plate heat exchanger that also needs descaling.Occasional

Can you fix it yourself?

What it costs to fix

Typical repair cost

£60–£140

Time on site

1 hour

A sensor plus draining the secondary side. Descaling the plate heat exchanger, if found, is extra.

Typical UK prices including parts and labour, updated September 2026. Your quote may differ.

Parts you may need

We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.

Viessmann DHW outlet temperature sensor

£15–£45Authorised Viessmann parts distributor

Price checked 28 September 2026

Own this appliance and had this code? . Nothing is published until a person has read it.

Written by

Andrew Pickett

Researcher and writer

Last updated

Technical review

Not reviewed by an engineer

No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.

What we check instead

Sources and how we verified this

We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.

  • Manufacturer technical and service documentation

This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.

Read our full verification process

Was this page helpful?