Viessmann F.64 fault codewhat it means and how to fix it

Get it checkedBoilerNumeric F-code display (2020 on): Vitodens 100-W B1HF/B1KF, B1HG/B1KG, B1GA; 111-W B1LF, B1LG; 050-W B0HA/B0KALast updated

Flame loss on a 2020-on Vitodens that the boiler recovered from by itself — a message, not a lockout. Worth a service visit before it becomes F.381; not a reason to reset anything.

Take care

Some of this is safe to check yourself, but the repair itself is not. If the fault comes back after one reset, stop resetting it and get a Gas Safe registered engineer to look at the Viessmann properly.

Get a Gas Safe registered engineer to look at your Viessmann F.64

We do not pass enquiries to a repair firm, so there is no form here. Find a Gas Safe registered engineer through the Gas Safe Register, and ask to see their registration card when they arrive — it is the register, not the van, that tells you they are qualified.

What F.64 means

F.64 has the wording of a fault and the behaviour of a note. The row reads "Normal operation; burner restarts — Flame loss during stabilisation or operating phase", and the difference from F.378, which uses the same cause text, is entirely in that first phrase. The burner lost its flame, the control unit relit it, heating carried on, and the event was logged so that the next engineer sees it under the "b.4" message history. Viessmann's measures are nevertheless the full flame-loss set — "Check gas supply (gas pressure and gas flow switch). Check balanced flue system for flue gas recirculation. Check ionisation electrode (replace if necessary). Check the distance of the electrode to the burner gauze assembly and its contamination level." — because the causes are the same as for the lockout; the boiler simply caught this one.

There is nothing for the householder to reset, and pressing the reset combination on a boiler that is running normally only interrupts it. What F.64 is useful for is warning. One occurrence in a winter is weather. A run of them in the history, or F.64 appearing on the display more than occasionally, is a burner working at the edge of its flame signal, and the next stage is the lockout row F.381 on a cold morning. The ionisation electrode is the part most often responsible and is replaced at a routine service; flue gas recirculation and gas pressure are the checks that go with it. Mention the code when booking the annual service so the contractor looks at the history rather than only at the boiler as it happens to be running that day.

What causes it

Causes of the Viessmann F.64 fault code, most common first
CauseWhat is actually happeningHow likely
Ionisation electrode ageingSignal strength falling with wear or deposits until a gust or a modulation step drops it below threshold for a moment. Replaced at service.Common
Gas pressure dipA neighbour's appliance starting on a shared supply, or a regulator hesitating. Momentary and self-correcting, which is why the burner relights.Common
Wind at the flue terminalA low-fire flame disturbed by a gust, particularly on an exposed wall. The balanced flue check in the row.Occasional
Flue gas recirculationA minor leak between flue and air duct that only matters at certain outputs. Found on the flue inspection.Rare

Can you fix it yourself?

What it costs to fix

Typical repair cost

£0–£120

Time on site

30 minutes

Nothing if it stays a one-off. An electrode changed at a service is the usual cost.

Typical UK prices including parts and labour, updated September 2026. Your quote may differ.

Parts you may need

We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.

Viessmann ionisation (flame-monitoring) electrode

£20–£55Authorised Viessmann parts distributor

Price checked 28 September 2026

Own this appliance and had this code? . Nothing is published until a person has read it.

Own a Viessmann boiler? Save it and its codes come first next time.

Written by

Andrew Pickett

Researcher and writer

Last updated

Technical review

Not reviewed by an engineer

No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.

What we check instead

Sources and how we verified this

We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.

  • Manufacturer technical and service documentation

This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.

Read our full verification process

Was this page helpful?