Viessmann F8 fault codewhat it means and how to fix it

Stop — call an engineerBoilerVitodens 100 WB1A, 100-W WB1A to B1HC/B1KC, 111-W B1LA to B1LD, 050-W BPJD; also Vitotronic-controlled 200-W B2HA/B2HB, 222-F B2TA, 242-F B2UALast updated

The gas train closed later than the control unit expected when the burner shut down. Viessmann treat it as a gas valve fault: lockout, no reset by the householder, Gas Safe engineer.

Get a Gas Safe registered engineer to look at your Viessmann F8

We do not pass enquiries to a repair firm, so there is no form here. Find a Gas Safe registered engineer through the Gas Safe Register, and ask to see their registration card when they arrive — it is the register, not the van, that tells you they are qualified.

What F8 means

F8 is "Burner in a fault state — Fuel valve closes too late" on the WB1A, WB1B, WB1C, B1HA/B1KA, B1HC/B1KC, the 111-W B1LA to B1LD and the 050-W BPJD. When the burner is told to stop, the control unit watches the flame signal disappear and expects it to do so within a defined time after the gas train is de-energised. If the flame persists past that window the only explanation the control unit will accept is that the fuel valve did not close when it was told to, and it locks out. Viessmann's measures are "Check gas train. Check both control paths." — the two control paths being the two independent ways the control unit drives the valve shut, either of which failing is a safety-chain fault.

Because the fault is about a valve that may be passing gas, this page gives no householder steps and carries the carbon monoxide flag. A single reset on the unit's own control (rotary selector to RESET on WB1B/WB1C/B1HA, "R" for two seconds on B1HC, the Reset key on WB1A, MODE and OK on BPJD) is what Viessmann's operating instructions allow before the contractor is called; an F8 that clears and returns is a gas train on its way out, not a glitch. The Vitotronic-controlled 200-W, 222-F and 242-F carry the same F8 — worded "Fuel valve or modulation valve will not close" in the 2019 B2HB edition, with "Check the gas train and replace if required. Press reset button R." — and the 2020-on numeric-table units report it as F.370 (gas valve or modulation valve will not close), which has its own page. A numeric-display boiler showing a plain 8 with the triangle is a different matter altogether — F.8 there is a cylinder temperature sensor short circuit, covered under 50/58.

What causes it

Causes of the Viessmann F8 fault code, most common first
CauseWhat is actually happeningHow likely
Gas train slow to closeWear or contamination in the valve seat means the armature does not drop cleanly when de-energised, so gas continues for a moment after the command to stop. The first of Viessmann's two measures.Common
Control path fault to the gas trainOne of the two drive paths from the burner control unit to the valve is stuck energised — a relay or output on the control unit. The second measure, "check both control paths".Occasional
Ionisation electrode holding a false flame signalIf the electrode keeps reporting a flame after the gas has genuinely stopped, the control unit reads it as a valve that closed late. Proven by checking the electrode before condemning the valve.Occasional

Can you fix it yourself?

What it costs to fix

Typical repair cost

£150–£450

Time on site

1h 30m

A gas train replacement is the usual outcome. If the control unit output is at fault the control unit is replaced instead, which is the higher figure.

Typical UK prices including parts and labour, updated September 2026. Your quote may differ.

Parts you may need

We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.

Viessmann ionisation (flame-monitoring) electrode

£20–£55Authorised Viessmann parts distributor

Price checked 28 September 2026

Viessmann gas train (gas valve assembly)

£150–£320Authorised Viessmann parts distributor

Price checked 28 September 2026

Viessmann burner control unit (control unit PCB / HBMU heat management unit)

£250–£500Authorised Viessmann parts distributor

Price checked 28 September 2026

Own this appliance and had this code? . Nothing is published until a person has read it.

Own a Viessmann boiler? Save it and its codes come first next time.

Written by

Andrew Pickett

Researcher and writer

Last updated

Technical review

Not reviewed by an engineer

No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.

What we check instead

Sources and how we verified this

We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.

  • Manufacturer technical and service documentation

This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.

Read our full verification process

Was this page helpful?