This fault can involve incomplete combustion and carbon monoxide.
If anyone in the property feels sick, dizzy or drowsy, or you can smell gas: open the windows, leave the building, and do not switch anything on or off. Then call the National Gas Emergency Service.
0800 111 999Viessmann F.387 fault codewhat it means and how to fix it
Earth fault in the ionisation (flame-monitoring) circuit on a 2020-on Vitodens; F.385, F.395, F.399, F.401, F.403 and F.405 are the same family. Electrode first, heat management unit if it persists. Engineer job.
Take care
Get a Gas Safe registered engineer to look at your Viessmann F.387
We do not pass enquiries to a repair firm, so there is no form here. Find a Gas Safe registered engineer through the Gas Safe Register, and ask to see their registration card when they arrive — it is the register, not the van, that tells you they are qualified.
What F.387 means
Seven rows in the numeric table describe the flame-monitoring circuit finding an unwanted path to earth. F.387 — "Burner in a fault state — Earth fault, ionisation current. HBMU heat management unit faulty." — is the plainest. F.385 is "Short circuit, signal 1, ionisation current"; F.395, F.399 and F.401 read "IO electrode earth fault, HBMU heat management unit faulty"; F.403 and F.405 "Ionisation electrode earth fault, HBMU heat management unit faulty". Viessmann's naming puts the unit in the cause line, but the measures make the order of suspicion clear: "Check ionisation electrode and connecting cable" (F.387), "Check IO electrode for earth fault" (F.385, F.399, F.401, F.403, F.405), "Check ignition electrode for earth fault" (F.395) — and only then "If the fault persists, replace the HBMU heat management unit. Reset the appliance." The flame-monitoring input is a high-impedance measurement of a tiny current through the flame; any leakage to earth swamps it, and the unit cannot tell a leak from a fault in its own circuitry, so it names both.
The ordinary causes are physical: a cracked electrode ceramic letting the signal track to the burner door, condensate wetting the electrode after a blocked trap, a cable pinched under the burner cover with its insulation cut, or a plug part-seated. All are found by the contractor with the burner exposed and are dealt with by an electrode set and a cable check. The heat management unit is the answer only when a proven-good electrode on a dry, sound cable still returns the code. There is no householder action beyond the single reset the operating instructions permit for a locked-out burner and the call if it comes back; a flame-monitoring fault is not one to keep resetting, because the circuit that would detect a failed ignition is the one in question.
What causes it
| Cause | What is actually happening | How likely |
|---|---|---|
| Electrode ceramic cracked | The insulator around the ionisation or ignition electrode fractured, letting the signal leak to earth. The usual cause and a routine part. | Common |
| Cable damaged or plug part-seated | Insulation cut where the lead passes the burner cover, or a connector not fully home after a service. F.387's "connecting cable". | Common |
| Moisture on the electrode | Condensate backing up into the heat cell wets the ceramic and bridges it to earth. The condensate trap is checked alongside. | Occasional |
| HBMU heat management unit | The fault survives a new electrode and a sound cable. Viessmann's last resort on every row in the family. | Rare |
Can you fix it yourself?
Stop — this needs an engineer
What it costs to fix
Typical repair cost
£80–£500
Time on site
1h 30m
Electrode set and visit at the low end. A heat management unit, if it comes to that, is the top figure.
Typical UK prices including parts and labour, updated September 2026. Your quote may differ.
Parts you may need
We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.
Viessmann ionisation (flame-monitoring) electrode
£20–£55Authorised Viessmann parts distributor
Price checked 28 September 2026
Viessmann ignition electrode set
£25–£65Authorised Viessmann parts distributor
Price checked 28 September 2026
Viessmann burner control unit (control unit PCB / HBMU heat management unit)
£250–£500Authorised Viessmann parts distributor
Price checked 28 September 2026
Own this appliance and had this code? . Nothing is published until a person has read it.
Related Viessmann fault codes
- F4Stop — call an engineerNo flame signal was detected during burner start on any two-character Vitodens, so the burner has locked out. Reset once; if it returns, call a Gas Safe engineer.Related: ignition and gas supply
- F.65Stop — call an engineerNo flame signal at burner start on a 2020-on Vitodens — the numeric table's equivalent of F4. Burner locked out. Check the gas is on, reset once; if it returns, call a Gas Safe engineer.Related: ignition and gas supply
- F3Stop — call an engineerThe control unit saw a flame signal before it had opened the gas — a flame where there should be none, or a false signal from the ionisation electrode. Lockout; Gas Safe engineer.Related: ignition and gas supply
- E5Get it checkedViessmann call E5 an "internal fault" but their only instruction is to check the ionisation electrode and its cables — a flame-monitoring fault, blocked not locked, and one for a Gas Safe engineer.Related: ignition and gas supply
- F.357Get it checkedInsufficient gas supply on a 2020-on Vitodens. F.353 is the softer version with output reduced; F.467, F.383 and F.384 blame calibration or a contaminated gas line. Check the gas is on, then call an engineer.Related: ignition and gas supply
- F.359Stop — call an engineerNo ignition spark on a 2020-on Vitodens, so the burner locked out before it could light. Ignition electrode, ignition module or heat management unit: a Gas Safe engineer's diagnosis.Related: ignition and gas supply
Own a Viessmann boiler? Save it and its codes come first next time.
Related guides
Technical review
Not reviewed by an engineer
No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.
Sources and how we verified this
We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.
- Manufacturer technical and service documentation
This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.