Viessmann F.347 fault codewhat it means and how to fix it

Stop — call an engineerBoilerNumeric F-code display (2020 on): Vitodens 100-W B1HF/B1KF, B1HG/B1KG, B1GA; 111-W B1LF, B1LG; 050-W B0HA/B0KALast updated

Flue gas recirculation detected on a 2020-on Vitodens — exhaust is getting back into the combustion air. F.463 adds contaminated air. Burner locked out; flue inspection by a Gas Safe engineer.

Get a Gas Safe registered engineer to look at your Viessmann F.347

We do not pass enquiries to a repair firm, so there is no form here. Find a Gas Safe registered engineer through the Gas Safe Register, and ask to see their registration card when they arrive — it is the register, not the van, that tells you they are qualified.

What F.347 means

F.347 — "Burner in a fault state — Flue gas recirculation" — is the combustion controller recognising its own exhaust in the air it is burning. Measures: "Check the flue system for leaks; remedy if necessary. Check the flue system for flue gas back pressure, e.g. caused by an insufficient fall in the flue system, constrictions or blockages. Rectify if necessary. Reset the appliance." F.463, "Contaminated combustion air, flue gas recirculation", is the same conclusion with the wider net: "Check flue system for contamination and flue gas recirculation. Clean flue system if required", plus Viessmann's standing note that deposits on the electrodes indicate foreign bodies in the combustion air — laundry detergents, cleaning agents, toiletries, a chimney used as an air supply — and that a boiler whose gauze assembly and electrode have been replaced should have its fan unit, gas/air channel and venturi extension cleaned as well.

On a concentric balanced flue the exhaust travels up the inner pipe and the air comes down the annulus around it; the two are separated by seals at every joint. A seal that has failed, a joint pulled apart in a loft, or a terminal fitted where the wind pushes exhaust straight back into the intake defeats that separation. A run with too little fall lets condensate pool until the flue gas has to push past it, and the back pressure forces exhaust out of any weak joint. This is not a householder repair at any point; the flue is part of the gas installation and inspecting it is Gas Safe work. The permitted single reset is available, but a recirculation code that returns after a reset should be left, because the next stage is F.352, the CO limit itself. Householders who can see their flue terminal can usefully look at it for obstruction, nests or ice while waiting for the engineer, and mention what they saw.

What causes it

Causes of the Viessmann F.347 fault code, most common first
CauseWhat is actually happeningHow likely
Flue joint or seal failedExhaust escaping from the inner pipe into the air annulus at a joint, elbow or terminal. Viessmann's first measure.Common
Insufficient fall and back pressureCondensate pooling in a horizontal run chokes the flue and forces exhaust back. Named in the row as the example of back pressure.Common
Terminal position or windA terminal in a corner, under an overhang or beside another appliance's outlet, where exhaust is drawn back into the intake.Occasional
Contaminated combustion air (F.463)Aerosols, lint, solvents or a dusty air supply in the boiler's room, leaving deposits on the electrodes. Cleaning the flue, fan unit and gas/air channel is the remedy.Occasional

Can you fix it yourself?

What it costs to fix

Typical repair cost

£90–£500

Time on site

2 hours

A seal or terminal repair with a combustion test at the low end; re-running a flue at the top.

Typical UK prices including parts and labour, updated September 2026. Your quote may differ.

Parts you may need

We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.

Viessmann ionisation (flame-monitoring) electrode

£20–£55Authorised Viessmann parts distributor

Price checked 28 September 2026

Viessmann Vitodens fan

£150–£300Authorised Viessmann parts distributor

Price checked 28 September 2026

Viessmann MatriX burner gauze assembly with insulation blocks

£120–£300Authorised Viessmann parts distributor

Price checked 28 September 2026

Own this appliance and had this code? . Nothing is published until a person has read it.

Own a Viessmann boiler? Save it and its codes come first next time.

Written by

Andrew Pickett

Researcher and writer

Last updated

Technical review

Not reviewed by an engineer

No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.

What we check instead