0800 111 999Viessmann F.347 fault codewhat it means and how to fix it
Flue gas recirculation detected on a 2020-on Vitodens — exhaust is getting back into the combustion air. F.463 adds contaminated air. Burner locked out; flue inspection by a Gas Safe engineer.
Stop — this needs an engineer
Get a Gas Safe registered engineer to look at your Viessmann F.347
We do not pass enquiries to a repair firm, so there is no form here. Find a Gas Safe registered engineer through the Gas Safe Register, and ask to see their registration card when they arrive — it is the register, not the van, that tells you they are qualified.
What F.347 means
F.347 — "Burner in a fault state — Flue gas recirculation" — is the combustion controller recognising its own exhaust in the air it is burning. Measures: "Check the flue system for leaks; remedy if necessary. Check the flue system for flue gas back pressure, e.g. caused by an insufficient fall in the flue system, constrictions or blockages. Rectify if necessary. Reset the appliance." F.463, "Contaminated combustion air, flue gas recirculation", is the same conclusion with the wider net: "Check flue system for contamination and flue gas recirculation. Clean flue system if required", plus Viessmann's standing note that deposits on the electrodes indicate foreign bodies in the combustion air — laundry detergents, cleaning agents, toiletries, a chimney used as an air supply — and that a boiler whose gauze assembly and electrode have been replaced should have its fan unit, gas/air channel and venturi extension cleaned as well.
On a concentric balanced flue the exhaust travels up the inner pipe and the air comes down the annulus around it; the two are separated by seals at every joint. A seal that has failed, a joint pulled apart in a loft, or a terminal fitted where the wind pushes exhaust straight back into the intake defeats that separation. A run with too little fall lets condensate pool until the flue gas has to push past it, and the back pressure forces exhaust out of any weak joint. This is not a householder repair at any point; the flue is part of the gas installation and inspecting it is Gas Safe work. The permitted single reset is available, but a recirculation code that returns after a reset should be left, because the next stage is F.352, the CO limit itself. Householders who can see their flue terminal can usefully look at it for obstruction, nests or ice while waiting for the engineer, and mention what they saw.
What causes it
| Cause | What is actually happening | How likely |
|---|---|---|
| Flue joint or seal failed | Exhaust escaping from the inner pipe into the air annulus at a joint, elbow or terminal. Viessmann's first measure. | Common |
| Insufficient fall and back pressure | Condensate pooling in a horizontal run chokes the flue and forces exhaust back. Named in the row as the example of back pressure. | Common |
| Terminal position or wind | A terminal in a corner, under an overhang or beside another appliance's outlet, where exhaust is drawn back into the intake. | Occasional |
| Contaminated combustion air (F.463) | Aerosols, lint, solvents or a dusty air supply in the boiler's room, leaving deposits on the electrodes. Cleaning the flue, fan unit and gas/air channel is the remedy. | Occasional |
Can you fix it yourself?
Stop — this needs an engineer
What it costs to fix
Typical repair cost
£90–£500
Time on site
2 hours
A seal or terminal repair with a combustion test at the low end; re-running a flue at the top.
Typical UK prices including parts and labour, updated September 2026. Your quote may differ.
Parts you may need
We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.
Viessmann ionisation (flame-monitoring) electrode
£20–£55Authorised Viessmann parts distributor
Price checked 28 September 2026
Viessmann Vitodens fan
£150–£300Authorised Viessmann parts distributor
Price checked 28 September 2026
Viessmann MatriX burner gauze assembly with insulation blocks
£120–£300Authorised Viessmann parts distributor
Price checked 28 September 2026
Own this appliance and had this code? . Nothing is published until a person has read it.
Related Viessmann fault codes
- EAStop — call an engineerA Lambda Pro combustion-controller code on Vitotronic-controlled 200-W, 222-F and 242-F boilers: the ionisation current during calibration was outside the permissible range or implausibly different from last time. Lockout; engineer.Related: combustion control
- F.352Stop — call an engineerThe combustion controller measured carbon monoxide above its limit on a 2020-on Vitodens and locked the burner out. Leave it off. The whole flue gas path is inspected by a Gas Safe engineer.Related: combustion control
- F.346Stop — call an engineerThe combustion controller on a 2020-on Vitodens could not calibrate its ionisation current. F.372, F.464, F.468 and F.377 lock out; F.374 to F.376 restart by themselves. Gas supply, electrode, flue and condensate: engineer's checks.Related: combustion control
- F.67Get it checkedIonisation current outside its permitted range on a 2020-on Vitodens; F.69, F.350 and F.351 are the same finding. The burner locks out until the electrode, gas supply and fan unit are checked by an engineer.Related: combustion control
- F4Stop — call an engineerNo flame signal was detected during burner start on any two-character Vitodens, so the burner has locked out. Reset once; if it returns, call a Gas Safe engineer.Related: same brand
- F.74Get it checkedSystem pressure too low on a 2020-on Vitodens with the numeric display. The burner and pump stop until the pressure is back. Viessmann tell the householder to top up below 1.0 bar.Related: same brand
Own a Viessmann boiler? Save it and its codes come first next time.
Related guides
Technical review
Not reviewed by an engineer
No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.
Sources and how we verified this
We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.
- Manufacturer technical and service documentation
This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.