Viessmann F.67 fault codewhat it means and how to fix it

Get it checkedBoilerF.67, F.69: Vitodens 100-W B1HF/B1KF, B1HG/B1KG, B1GA; 111-W B1LF, B1LG; 050-W B0HA/B0KA. F.350/F.351: B1GA and B0HA/B0KA tablesLast updated

Ionisation current outside its permitted range on a 2020-on Vitodens; F.69, F.350 and F.351 are the same finding. The burner locks out until the electrode, gas supply and fan unit are checked by an engineer.

Take care

Some of this is safe to check yourself, but the repair itself is not. If the fault comes back after one reset, stop resetting it and get a Gas Safe registered engineer to look at the Viessmann properly.

Get a Gas Safe registered engineer to look at your Viessmann F.67

We do not pass enquiries to a repair firm, so there is no form here. Find a Gas Safe registered engineer through the Gas Safe Register, and ask to see their registration card when they arrive — it is the register, not the van, that tells you they are qualified.

What F.67 means

Four numbers in the numeric table carry the cause "Ionisation current lies outside the permissible range": F.67, F.69, and on the B1GA and 050-W B0HA/B0KA tables F.350 and F.351 as a pair. All are "Burner in a fault state". On these boilers the ionisation current is not only proof of flame but the signal the electronic combustion controller regulates air ratio from — Viessmann's appendix explains that the current peaks at an air ratio of 1 and the controller holds the burner between λ 1.2 and 1.5 by reading it — so a current the controller cannot make sense of is a combustion it cannot regulate, and it stops. F.67's measures start outside the burner: "Check gas supply (gas pressure and gas flow switch), check gas solenoid valve and inlet strainer", then the electrode's distance to the burner gauze and contamination of either, and finally "If specified measures don't help, replace fan unit." F.69's are more specific: whether the insulation block is touching the electrode ceramic, a gas-valve test at the lower heating output for about four minutes under service menu "b.6" (if the fault occurs, the HBMU heat management unit is replaced), then switching to the upper output — if the fault appears during modulation, the intake screen is checked for contamination and the fan unit replaced if necessary.

The fan unit appearing as a remedy for an electrode fault is not a misprint. On these Vitodens the gas/air mixture is formed in the fan unit's venturi and a contaminated intake screen or a worn fan skews the mixture, which the ionisation reading then reports as implausible. It is also why Viessmann's note about deposits on electrodes indicating foreign bodies in the combustion air matters: a boiler in a utility room full of tumble-dryer lint or laundry aerosols will show these codes long before a boiler in a clean cupboard. The householder's options are the single arrow-key reset and the call to the contractor if the code recurs.

What causes it

Causes of the Viessmann F.67 fault code, most common first
CauseWhat is actually happeningHow likely
Ionisation electrode gap or contaminationToo far from the gauze, coated, or with the insulation block touching its ceramic (F.69's first check). Cheap, common, and the first thing replaced.Common
Gas supply or gas solenoid valve strainerLow working pressure or a strainer blocked with debris from the pipework changes the mixture at the burner. F.67's first measure.Common
Contaminated intake or fan unitDust, lint or aerosol residue on the intake screen, or a fan unit whose venturi no longer meters air correctly. Viessmann's final remedy on both rows.Occasional
HBMU heat management unitIf the fault appears during the four-minute lower-output test in F.69's procedure, the unit itself is replaced. Rare.Rare

Can you fix it yourself?

What it costs to fix

Typical repair cost

£80–£300

Time on site

1h 30m

An electrode at the low end; a fan unit at the top. A heat management unit would exceed the range but is the least likely finding.

Typical UK prices including parts and labour, updated September 2026. Your quote may differ.

Parts you may need

We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.

Viessmann ionisation (flame-monitoring) electrode

£20–£55Authorised Viessmann parts distributor

Price checked 28 September 2026

Viessmann gas train (gas valve assembly)

£150–£320Authorised Viessmann parts distributor

Price checked 28 September 2026

Viessmann Vitodens fan

£150–£300Authorised Viessmann parts distributor

Price checked 28 September 2026

Own this appliance and had this code? . Nothing is published until a person has read it.

Own a Viessmann boiler? Save it and its codes come first next time.

Written by

Andrew Pickett

Researcher and writer

Last updated

Technical review

Not reviewed by an engineer

No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.

What we check instead