Viessmann 0A fault codewhat it means and how to fix it

Stop — call an engineerBoilerVitodens 100-W B1HC/B1KC and 111-W B1LD with a CO limiter or gas pressure switch fitted. Not on earlier units or the 050-W BPJDLast updated

On the B1HC-generation 100-W and 111-W, 0A means a fitted CO limiter has responded to carbon monoxide, or a fitted gas pressure switch has seen gas pressure fall. Switch off; Gas Safe engineer.

Get a Gas Safe registered engineer to look at your Viessmann 0A

We do not pass enquiries to a repair firm, so there is no form here. Find a Gas Safe registered engineer through the Gas Safe Register, and ask to see their registration card when they arrive — it is the register, not the van, that tells you they are qualified.

What 0A means

0A appears on the Vitodens 100-W B1HC/B1KC and 111-W B1LD (2016 to 2020) and carries two rows in Viessmann's table, both marked "if installed". The first is "Burner blocked — CO limiter (if installed) has responded. CO concentration too high. — Check the heating system. Remove the cause of escaping CO." The second is "Burner blocked — Gas pressure switch (if installed) has responded. Gas pressure too low. — Check the gas supply." Neither device is standard on a UK domestic installation — a CO limiter is an optional accessory, and a gas pressure switch is normally fitted where the supply is marginal or shared — so 0A on a boiler that has neither fitted should not appear. On one that has, the first row is the only code in the whole Viessmann two-character table that names carbon monoxide, and Viessmann's measure is not to reset it but to remove the cause of the escaping gas.

Because the burner is blocked rather than locked out, the boiler may attempt to run again if the condition clears, which with a CO limiter is not a reassurance. Treat 0A as you would a CO alarm: switch the boiler off, ventilate, and do not run it again until a Gas Safe engineer has found the cause. If your installation has a gas pressure switch and no CO limiter, the code means the supply pressure dropped below the switch setting while the burner ran — a governor, a shared supply under load, or an LPG regulator — and the engineer's check is the gas supply. The code is absent from every earlier two-character unit and from the 050-W BPJD. On the 2020-on numeric-table units the equivalents are F.352 (combustion CO limit exceeded) and F.368 (gas pressure switch fault).

What causes it

Causes of the Viessmann 0A fault code, most common first
CauseWhat is actually happeningHow likely
Carbon monoxide detected by the fitted CO limiterProducts of combustion escaping into the room — a flue leak, spillage from a compartment, or a heat exchanger fault. Viessmann: remove the cause of escaping CO.Occasional
Gas pressure too low at the fitted gas pressure switchSupply pressure fell below the switch setting while the burner ran. A governor, a meter, a shared supply under load, or an LPG regulator or empty cylinder. Viessmann: check the gas supply.Occasional
Limiter or switch wiringA device fitted but wired wrongly, or a lead that has failed, produces 0A with nothing wrong in the room or the supply. Diagnosed after the two real causes are excluded, never before.Rare

Can you fix it yourself?

What it costs to fix

Typical repair cost

£70–£300

Time on site

1h 30m

A gas supply check is a call-out; a flue repair or a heat exchanger inspection is the higher figure. A CO alarm, if you do not have one, is under £30 and is the thing to buy first.

Typical UK prices including parts and labour, updated September 2026. Your quote may differ.

Own this appliance and had this code? . Nothing is published until a person has read it.

Own a Viessmann boiler? Save it and its codes come first next time.

Written by

Andrew Pickett

Researcher and writer

Last updated

Technical review

Not reviewed by an engineer

No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.

What we check instead

Sources and how we verified this

We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.

  • Manufacturer technical and service documentation

This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.

Read our full verification process

Was this page helpful?