Get it checkedBoilerNumeric F-code display (2020 on): Vitodens 100-W B1HF/B1KF, B1HG/B1KG, B1GA; 111-W B1LF, B1LG; 050-W B0HA/B0KALast updated

Hot water stopped on a 2020-on Vitodens because the boiler could not get enough flow through itself before (F.980) or during (F.981) cylinder heating. Heating carries on. Cylinder valves, air and pump for the engineer.

Take care

Some of this is safe to check yourself, but the repair itself is not. If the fault comes back after one reset, stop resetting it and get a Gas Safe registered engineer to look at the Viessmann properly.

Get a Gas Safe registered engineer to look at your Viessmann F.980

We do not pass enquiries to a repair firm, so there is no form here. Find a Gas Safe registered engineer through the Gas Safe Register, and ask to see their registration card when they arrive — it is the register, not the van, that tells you they are qualified.

What F.980 means

F.980 and F.981 belong to the way these boilers protect themselves when heating a hot water cylinder. Viessmann's function description explains it: before DHW heating the internal flow rate is monitored, and if the threshold is not reached the diverter valve returns to the heating position for five minutes, then tries again; after four failed attempts, about twenty minutes, F.980 is output and DHW heating is blocked for the period set in parameter 1087.0, with heating still available. F.981 is the same logic applied while cylinder heating is under way — flow drops below the threshold, the valve returns to heating for five minutes, and after four failures the fault is shown. The rows list the causes together: "Shut-off or too much constriction. Scaling or sludge. Incorrect hydraulic configuration. Circulation pump faulty, air in the heating circuit. System pressure unstable or too low." On the B1GA and 050-W B0HA/B0KA the same numbers read simply "Water flow rate below minimum level".

The measures are a checklist for the installer as much as the repairer: every cylinder shut-off device fully open, the hydraulic scheme set correctly in the commissioning assistant, the system fully vented (Viessmann's venting programme can be run again from the service menu), the quick-action air vents on the appliance side permanently open and not leaking, the set system pressure checked ("this fault is more likely if the system pressure is too low"), and the circulation pump. Two things matter to the householder. First, this is a hot-water fault on a boiler that is still heating the house, so it is not an emergency. Second, Viessmann say the blocking time "can be terminated by carrying out a mains reset. Switch the appliance off and on again at the appliance switch" — the one action available from outside the case. A boiler that needs that every day has a real flow problem. The two-character units have no equivalent row; their 52/5A is the combi's tap-flow turbine, a different device.

What causes it

Causes of the Viessmann F.980 fault code, most common first
CauseWhat is actually happeningHow likely
Air in the primary circuitAfter filling or work, air pockets in the boiler or cylinder coil stall the flow the monitoring expects. Viessmann's venting programme and the quick-action vents are the remedy.Common
Cylinder valve closed or restrictedA shut-off on the cylinder flow or return not fully open, or a constriction in the pipework. First measure in the row.Common
Low or unstable system pressureNamed in the row as making the fault more likely. Often a flat expansion vessel behind it.Occasional
Scale, sludge or a tired pumpA furred cylinder coil or a sludged circuit raises the resistance; a pump that cannot push through it fails the threshold. The expensive end.Occasional
Hydraulic scheme set wronglyA commissioning parameter that tells the boiler to expect a flow path it does not have. Rare after commissioning.Rare

Can you fix it yourself?

What it costs to fix

Typical repair cost

£0–£320

Time on site

1h 30m

A valve opened or a system vented is a short visit. A pump, or a cylinder coil descale, is the top figure.

Typical UK prices including parts and labour, updated September 2026. Your quote may differ.

Parts you may need

We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.

Viessmann internal circulation pump

£150–£300Authorised Viessmann parts distributor

Price checked 28 September 2026

Viessmann diaphragm expansion vessel (Vitodens internal)

£70–£200Authorised Viessmann parts distributor

Price checked 28 September 2026

Viessmann 3-way diverter valve (motor and cartridge)

£60–£180Authorised Viessmann parts distributor

Price checked 28 September 2026

Own this appliance and had this code? . Nothing is published until a person has read it.

Own a Viessmann boiler? Save it and its codes come first next time.

Written by

Andrew Pickett

Researcher and writer

Last updated

Technical review

Not reviewed by an engineer

No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.

What we check instead

Sources and how we verified this

We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.

  • Manufacturer technical and service documentation

This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.