Viessmann F.63 fault codewhat it means and how to fix it

Stop — call an engineerBoilerNumeric F-code display (2020 on): Vitodens 100-W B1HF/B1KF, B1HG/B1KG, B1GA; 111-W B1LF, B1LG; 050-W B0HA/B0KALast updated

The flue gas temperature limiter has tripped on a 2020-on Vitodens and the burner is locked out. Reset only once the flue has cooled; the cause is a circulation check for a Gas Safe engineer.

Get a Gas Safe registered engineer to look at your Viessmann F.63

We do not pass enquiries to a repair firm, so there is no form here. Find a Gas Safe registered engineer through the Gas Safe Register, and ask to see their registration card when they arrive — it is the register, not the van, that tells you they are qualified.

What F.63 means

F.63 reads "Burner in a fault state — Flue gas temperature limiter has responded." on every numeric-table Vitodens. Where F.62 watches the water leaving the heat exchanger, F.63 watches the flue gas leaving it: a sensor in the flue connection that trips when the products of combustion run hotter than the plastic flue is rated for. Hot flue gas is a symptom of the heat exchanger not giving up its heat, and Viessmann's measures are therefore the same as for the high limit: "Check heating system fill level. Check pre-charge pressure in diaphragm expansion vessel. Adjust to required system pressure. Check whether flow rate is sufficient (circulation pump). Check function of 3-way diverter valve. Vent the system." The last line is the one that differs: "Reset the appliance once the flue system has cooled down."

That instruction is about the flue, not the boiler. A plastic flue that has been overheated needs time before the sensor will accept a restart, and Viessmann make the same point on the two-character units, whose F3 row carries the identical condition. The householder may reset once with the arrow keys, and if the code returns the operating instructions say to notify the heating contractor. A flue gas limiter that trips repeatedly on a boiler with good circulation points to the heat exchanger itself — scaled or sludged on the water side, or blocked with combustion deposits on the gas side, both of which stop heat crossing the wall between them. The flue gas temperature sensor has its own rows, F.49 and F.50, when it fails electrically rather than trips.

What causes it

Causes of the Viessmann F.63 fault code, most common first
CauseWhat is actually happeningHow likely
Poor circulation through the heat exchangerPump, diverter valve or air, exactly as for F.62. Water that is not moving cannot carry heat away, and the flue gas leaves hot.Common
Heat exchanger fouledScale or sludge on the water side, or deposits between the coils on the combustion side, insulate the wall and push flue gas temperature up. A cleaning and flushing job.Common
Low fill level or flat expansion vesselThe first three measures in the row. A boiler running with too little water in it heats what there is very quickly.Occasional
Sensor or leadA flue gas sensor reading high, or a poor connection. If the electrical fault is outright the boiler shows F.49 or F.50 instead.Rare

Can you fix it yourself?

What it costs to fix

Typical repair cost

£80–£350

Time on site

2 hours

A pump or valve repair mid-range; a heat exchanger clean and system flush at the top.

Typical UK prices including parts and labour, updated September 2026. Your quote may differ.

Parts you may need

We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.

Viessmann flue gas temperature sensor

£25–£60Authorised Viessmann parts distributor

Price checked 28 September 2026

Viessmann internal circulation pump

£150–£300Authorised Viessmann parts distributor

Price checked 28 September 2026

Viessmann 3-way diverter valve (motor and cartridge)

£60–£180Authorised Viessmann parts distributor

Price checked 28 September 2026

Own this appliance and had this code? . Nothing is published until a person has read it.

Own a Viessmann boiler? Save it and its codes come first next time.

Written by

Andrew Pickett

Researcher and writer

Last updated

Technical review

Not reviewed by an engineer

No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.

What we check instead

Sources and how we verified this

We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.

  • Manufacturer technical and service documentation

This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.

Read our full verification process