This fault can involve incomplete combustion and carbon monoxide.
If anyone in the property feels sick, dizzy or drowsy, or you can smell gas: open the windows, leave the building, and do not switch anything on or off. Then call the National Gas Emergency Service.
0800 111 999Viessmann F.370 fault codewhat it means and how to fix it
The gas or modulation valve on a 2020-on Vitodens did not close when told to; burner locked out. F.365 to F.367 are the control side. Leave the boiler off; call a Gas Safe engineer.
Stop — this needs an engineer
Get a Gas Safe registered engineer to look at your Viessmann F.370
We do not pass enquiries to a repair firm, so there is no form here. Find a Gas Safe registered engineer through the Gas Safe Register, and ask to see their registration card when they arrive — it is the register, not the van, that tells you they are qualified.
What F.370 means
F.370 — "Burner in a fault state — Gas valve or modulation valve will not close." — is the numeric table's version of the two-character F8, and the same safety logic sits behind it: when the burner is commanded off, the control unit watches the flame signal disappear, and a flame that lingers past the permitted time can only mean gas still flowing through a valve that should be shut. Viessmann's measures are short: "Reset the appliance. If fault occurs repeatedly, replace fan unit." The fan unit is named because on these boilers the modulation valve that meters gas into the venturi is part of the gas/air unit rather than a separate gas train, so a sticking modulation valve is a fan unit replacement. F.365, "Feedback from gas valve relay contact implausible (relay contact is welded up)", and F.366/F.367, "Gas valve electricity supply does not turn off", are the same fault seen from the control side — the HBMU heat management unit's own relay has stuck or its drive will not release — and for those the only measure is to replace the heat management unit.
This is a row to take literally. A valve that may be passing gas is the reason Viessmann print their warning about resets beside every lockout, and a single reset — the arrow keys, after the burner has cooled — is the most the operating instructions permit before the contractor is called. If F.370 returns, or if there is any smell of gas, the boiler should be switched off at its ON/OFF switch and the gas shut-off valve closed, and the fault treated as urgent. There is no householder repair. The Vitotronic 200-W words the same event "Fuel valve or modulation valve will not close" under F8; the two-character 100-W rows say "Fuel valve closes too late".
What causes it
| Cause | What is actually happening | How likely |
|---|---|---|
| Modulation valve sticking | The gas-metering valve in the fan unit not seating when de-energised. Viessmann's remedy for a repeat F.370 is the fan unit itself. | Common |
| Heat management unit relay stuck (F.365 to F.367) | A welded relay contact or a drive that will not switch off keeps the valve energised. The HBMU is replaced; there is no reset branch. | Occasional |
| Flame signal persisting for another reason | An ionisation signal that lingers after the valve has genuinely shut — a wet or earthed electrode — can mimic a valve fault. Checked before the fan unit is condemned. | Occasional |
| Gas train fault | Where the boiler has a separate gas solenoid valve, a valve that closes slowly. Less common on these units than the modulation valve. | Rare |
Can you fix it yourself?
Stop — this needs an engineer
What it costs to fix
Typical repair cost
£150–£550
Time on site
2 hours
A fan unit at the low to middle of the range; a heat management unit fitted and parameterised at the top.
Typical UK prices including parts and labour, updated September 2026. Your quote may differ.
Parts you may need
We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.
Viessmann gas train (gas valve assembly)
£150–£320Authorised Viessmann parts distributor
Price checked 28 September 2026
Viessmann Vitodens fan
£150–£300Authorised Viessmann parts distributor
Price checked 28 September 2026
Viessmann burner control unit (control unit PCB / HBMU heat management unit)
£250–£500Authorised Viessmann parts distributor
Price checked 28 September 2026
Own this appliance and had this code? . Nothing is published until a person has read it.
Related Viessmann fault codes
- F4Stop — call an engineerNo flame signal was detected during burner start on any two-character Vitodens, so the burner has locked out. Reset once; if it returns, call a Gas Safe engineer.Related: ignition and gas supply
- F.65Stop — call an engineerNo flame signal at burner start on a 2020-on Vitodens — the numeric table's equivalent of F4. Burner locked out. Check the gas is on, reset once; if it returns, call a Gas Safe engineer.Related: ignition and gas supply
- F3Stop — call an engineerThe control unit saw a flame signal before it had opened the gas — a flame where there should be none, or a false signal from the ionisation electrode. Lockout; Gas Safe engineer.Related: ignition and gas supply
- E5Get it checkedViessmann call E5 an "internal fault" but their only instruction is to check the ionisation electrode and its cables — a flame-monitoring fault, blocked not locked, and one for a Gas Safe engineer.Related: ignition and gas supply
- F.357Get it checkedInsufficient gas supply on a 2020-on Vitodens. F.353 is the softer version with output reduced; F.467, F.383 and F.384 blame calibration or a contaminated gas line. Check the gas is on, then call an engineer.Related: ignition and gas supply
- F.359Stop — call an engineerNo ignition spark on a 2020-on Vitodens, so the burner locked out before it could light. Ignition electrode, ignition module or heat management unit: a Gas Safe engineer's diagnosis.Related: ignition and gas supply
Own a Viessmann boiler? Save it and its codes come first next time.
Related guides
Technical review
Not reviewed by an engineer
No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.
Sources and how we verified this
We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.
- Manufacturer technical and service documentation
This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.