Viessmann E6 fault codewhat it means and how to fix it

Get it checkedBoilerVitodens 100 WB1A, 100-W WB1A and early WB1B (2008 edition); Vitotronic 200-W B2HA, 242-F B2UA. Later 100-W units flash the pressure reading insteadLast updated

System water pressure too low — a code only on the WB1A, early WB1B and Vitotronic 200-W. Viessmann's measure is to top up with water; later 100-W units show the flashing pressure instead.

Take care

Some of this is safe to check yourself, but the repair itself is not. If the fault comes back after one reset, stop resetting it and get a Gas Safe registered engineer to look at the Viessmann properly.

What E6 means

E6 is one of the few Viessmann codes with a householder remedy printed against it. The first-generation Vitodens 100 and 100-W WB1A gives "E6 — Burner blocked — Water pressure too low — Top up water", the 2008 WB1B installation instructions carry the same row, and the Vitotronic-controlled 200-W B2HA and 242-F B2UA read "Burner blocked — System pressure too low — Top up with water." The control unit reads a pressure sensor in the primary circuit and refuses to fire below the minimum; because the burner is blocked rather than locked out, it starts again on its own once pressure is restored, so there is no reset. What changes by unit is whether you see a code at all. The 2011 WB1B service instructions, the WB1C, B1HA and B1HC tables and the 050-W BPJD have no E6: on those the operating instructions say the system pressure reading flashes on the display instead, and the B1HC operating instructions give 0.8 bar as the minimum.

The householder instruction comes from Viessmann's WB1A operating instructions: low system water pressure is shown flashing, contact your heating engineer, and "it is possible to recharge the system via the filling loop", with the warning that care must be taken to ensure the fill valve is not left turned on. The Vitotronic operating instructions are more reserved, telling the owner to ask the heating contractor for the required system pressure and the position of the shut-off valves, so on a 200-W or 242-F the steps below apply only if your installer has shown you the filling loop. A system that needs topping up more than once or twice a year is losing water somewhere, and that is the contractor's. On the 2020-on numeric-table units the equivalent is F.74 (system pressure too low), which stops both the burner and the pump; F.87 is pressure too high and F.471 a pressure sensor fault.

What causes it

Causes of the Viessmann E6 fault code, most common first
CauseWhat is actually happeningHow likely
Normal loss over timeSmall losses through radiator bleeds and the pressure relief valve bring a sealed system down over months. A top-up once or twice a year is ordinary.Common
Leak on the systemA weeping radiator valve, a joint under a floor, or a relief valve discharging outside. Needs topping up repeatedly and gets worse.Common
Expansion vessel lost its chargePressure that swings high when hot and low when cold points at the vessel, not a leak. A contractor recharges or replaces it.Occasional
Pressure sensor faultOn the WB1A a faulty sensor is its own code, F7; on the Vitotronic units a sensor reading low with the gauge normal is the finding.Rare

What to try yourself

  1. Read the pressure gauge with the boiler cold. On the B1HC-generation 100-W Viessmann give 0.8 bar as the minimum; on other units ask your installer for the figure, and take a note of the reading before you do anything.

  2. If your installer has shown you the filling loop, open its valves slowly until the gauge reaches the pressure they set, then close both valves fully. Viessmann's own warning: care must be taken to ensure the fill valve is not left turned on. The burner restarts by itself once pressure is back.

    If you have not been shown the filling loop, or the pressure drops again within days, stop and call your heating contractor. Repeated topping up hides a leak and wears the boiler.

Get a Gas Safe registered engineer to look at your Viessmann E6

We do not pass enquiries to a repair firm, so there is no form here. Find a Gas Safe registered engineer through the Gas Safe Register, and ask to see their registration card when they arrive — it is the register, not the van, that tells you they are qualified.

What it costs to fix

Typical repair cost

£0–£250

Time on site

15 minutes

A top-up costs nothing. Finding and fixing a leak, or replacing an expansion vessel, is the higher figure.

Typical UK prices including parts and labour, updated September 2026. Your quote may differ.

Parts you may need

We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.

Viessmann water pressure sensor

£30–£75Authorised Viessmann parts distributor

Price checked 28 September 2026

Own this appliance and had this code? . Nothing is published until a person has read it.

Own a Viessmann boiler? Save it and its codes come first next time.

Written by

Andrew Pickett

Researcher and writer

Last updated

Technical review

Not reviewed by an engineer

No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.

What we check instead

Sources and how we verified this

We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.

  • Manufacturer technical and service documentation

This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.

Read our full verification process

Was this page helpful?