Viessmann E6 fault codewhat it means and how to fix it
System water pressure too low — a code only on the WB1A, early WB1B and Vitotronic 200-W. Viessmann's measure is to top up with water; later 100-W units show the flashing pressure instead.
Take care
What E6 means
E6 is one of the few Viessmann codes with a householder remedy printed against it. The first-generation Vitodens 100 and 100-W WB1A gives "E6 — Burner blocked — Water pressure too low — Top up water", the 2008 WB1B installation instructions carry the same row, and the Vitotronic-controlled 200-W B2HA and 242-F B2UA read "Burner blocked — System pressure too low — Top up with water." The control unit reads a pressure sensor in the primary circuit and refuses to fire below the minimum; because the burner is blocked rather than locked out, it starts again on its own once pressure is restored, so there is no reset. What changes by unit is whether you see a code at all. The 2011 WB1B service instructions, the WB1C, B1HA and B1HC tables and the 050-W BPJD have no E6: on those the operating instructions say the system pressure reading flashes on the display instead, and the B1HC operating instructions give 0.8 bar as the minimum.
The householder instruction comes from Viessmann's WB1A operating instructions: low system water pressure is shown flashing, contact your heating engineer, and "it is possible to recharge the system via the filling loop", with the warning that care must be taken to ensure the fill valve is not left turned on. The Vitotronic operating instructions are more reserved, telling the owner to ask the heating contractor for the required system pressure and the position of the shut-off valves, so on a 200-W or 242-F the steps below apply only if your installer has shown you the filling loop. A system that needs topping up more than once or twice a year is losing water somewhere, and that is the contractor's. On the 2020-on numeric-table units the equivalent is F.74 (system pressure too low), which stops both the burner and the pump; F.87 is pressure too high and F.471 a pressure sensor fault.
What causes it
| Cause | What is actually happening | How likely |
|---|---|---|
| Normal loss over time | Small losses through radiator bleeds and the pressure relief valve bring a sealed system down over months. A top-up once or twice a year is ordinary. | Common |
| Leak on the system | A weeping radiator valve, a joint under a floor, or a relief valve discharging outside. Needs topping up repeatedly and gets worse. | Common |
| Expansion vessel lost its charge | Pressure that swings high when hot and low when cold points at the vessel, not a leak. A contractor recharges or replaces it. | Occasional |
| Pressure sensor fault | On the WB1A a faulty sensor is its own code, F7; on the Vitotronic units a sensor reading low with the gauge normal is the finding. | Rare |
What to try yourself
Read the pressure gauge with the boiler cold. On the B1HC-generation 100-W Viessmann give 0.8 bar as the minimum; on other units ask your installer for the figure, and take a note of the reading before you do anything.
If your installer has shown you the filling loop, open its valves slowly until the gauge reaches the pressure they set, then close both valves fully. Viessmann's own warning: care must be taken to ensure the fill valve is not left turned on. The burner restarts by itself once pressure is back.
If you have not been shown the filling loop, or the pressure drops again within days, stop and call your heating contractor. Repeated topping up hides a leak and wears the boiler.
Get a Gas Safe registered engineer to look at your Viessmann E6
We do not pass enquiries to a repair firm, so there is no form here. Find a Gas Safe registered engineer through the Gas Safe Register, and ask to see their registration card when they arrive — it is the register, not the van, that tells you they are qualified.
What it costs to fix
Typical repair cost
£0–£250
Time on site
15 minutes
A top-up costs nothing. Finding and fixing a leak, or replacing an expansion vessel, is the higher figure.
Typical UK prices including parts and labour, updated September 2026. Your quote may differ.
Parts you may need
We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.
Viessmann water pressure sensor
£30–£75Authorised Viessmann parts distributor
Price checked 28 September 2026
Own this appliance and had this code? . Nothing is published until a person has read it.
Related Viessmann fault codes
- F.74Get it checkedSystem pressure too low on a 2020-on Vitodens with the numeric display. The burner and pump stop until the pressure is back. Viessmann tell the householder to top up below 1.0 bar.Related: water pressure
- F.87Get it checkedSystem pressure too high on a numeric-display Vitodens. Burner and internal pump stop. Usually an overfilled system or a flat expansion vessel; the contractor checks vessel charge and the pressure sensor.Related: water pressure
- F.471Get it checkedThe system pressure sensor is missing, open-circuit or shorted on a 2020-on Vitodens, so the boiler will not run at all. A sensor and lead check for the engineer.Related: water pressure
- F4Stop — call an engineerNo flame signal was detected during burner start on any two-character Vitodens, so the burner has locked out. Reset once; if it returns, call a Gas Safe engineer.Related: same brand
- F.65Stop — call an engineerNo flame signal at burner start on a 2020-on Vitodens — the numeric table's equivalent of F4. Burner locked out. Check the gas is on, reset once; if it returns, call a Gas Safe engineer.Related: same brand
- EAStop — call an engineerA Lambda Pro combustion-controller code on Vitotronic-controlled 200-W, 222-F and 242-F boilers: the ionisation current during calibration was outside the permissible range or implausibly different from last time. Lockout; engineer.Related: same brand
Own a Viessmann boiler? Save it and its codes come first next time.
Related guides
Technical review
Not reviewed by an engineer
No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.
Sources and how we verified this
We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.
- Manufacturer technical and service documentation
This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.