Vaillant F.73 fault codewhat it means and how to fix it

Get it checkedBoilerecoTEC plus and pro 2005–2021, ecoTEC exclusive, ecoFIT pure and sustain and the open-vent ecoTEC plus (signal too low: broken cable, short to 0 V, sensor). ecoTEC sustain: the same number means the sensor short-circuited, with the interruption moved to F.74. Not printed for the ecoTEC plus CS/1-5.Last updated

The pressure sensor signal is out of range at the low end. Usually the sensor or its wiring, rather than the pressure itself.

Take care

Some of this is safe to check yourself, but the repair itself is not. If the fault comes back after one reset, stop resetting it and get a Gas Safe registered engineer to look at the Vaillant properly.

Get a Gas Safe registered engineer to look at your Vaillant F.73

We do not pass enquiries to a repair firm, so there is no form here. Find a Gas Safe registered engineer through the Gas Safe Register, and ask to see their registration card when they arrive — it is the register, not the van, that tells you they are qualified.

What F.73 means

F.73 and F.22 are easily confused and the difference is worth getting right. F.22 means the appliance has read the pressure and found it too low. F.73 means the appliance cannot get a sensible reading from the sensor at all — Vaillant describe it as the water pressure sensor signal being out of range at the low end, caused by a broken cable, a short circuit to 0V, or a defective sensor.

In other words, F.22 is about the water and F.73 is about the measurement. That distinction has a practical consequence: on an F.73 the pressure gauge will very often read perfectly normally, and topping the system up will change nothing at all. People frequently refill two or three times before working that out. The good news is that a pressure sensor and its wiring are among the cheaper repairs on a Vaillant, and the fault is straightforward for an engineer to confirm with a multimeter.

One generation words it the other way round, and it matters if you own one: the ecoTEC sustain manual prints F.73 as "water pressure sensor short-circuited" and gives the interruption — the broken cable — to F.74, which is the reverse of the ecoTEC plus and pro. The 2022 CS/1-5 has no F.073 at all; its F.074 covers the interrupted signal. Whichever way round your boiler prints it, the engineer's job is the same circuit.

What causes it

Causes of the Vaillant F.73 fault code, most common first
CauseWhat is actually happeningHow likely
Pressure sensor failedGone open circuit or drifted outside the range the board will accept. The most likely explanation and a modest part cost.Common
Cable to the sensor broken or shortedVaillant name a broken cable and a short to 0V specifically. A wiring fault is cheaper than a sensor and worth eliminating first.Common
Connector corroded or unseatedFrequently follows previous work on the appliance, or damp inside the case. Costs nothing but the call-out if that is all it is.Occasional
Control board input faultThe board cannot read a healthy sensor. Considered only after the sensor and its wiring have been measured.Rare

Can you fix it yourself?

What it costs to fix

Typical repair cost

£90–£260

A wiring or connector repair is a call-out charge of £80 to £150. A pressure sensor is £130 to £240 fitted.

Typical UK prices including parts and labour, updated September 2026. Your quote may differ.

Parts you may need

We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.

Vaillant ecoTEC water pressure sensor

0020059717£26–£54Authorised Vaillant parts distributor

Price checked 28 September 2026

Own this appliance and had this code? . Nothing is published until a person has read it.

Written by

Andrew Pickett

Researcher and writer

Last updated

Technical review

Not reviewed by an engineer

No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.

What we check instead

Sources and how we verified this

We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.

  • Manufacturer technical and service documentation

This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.

Read our full verification process

Was this page helpful?