Vaillant F.73 fault codewhat it means and how to fix it
The pressure sensor signal is out of range at the low end. Usually the sensor or its wiring, rather than the pressure itself.
Take care
Get a Gas Safe registered engineer to look at your Vaillant F.73
We do not pass enquiries to a repair firm, so there is no form here. Find a Gas Safe registered engineer through the Gas Safe Register, and ask to see their registration card when they arrive — it is the register, not the van, that tells you they are qualified.
What F.73 means
F.73 and F.22 are easily confused and the difference is worth getting right. F.22 means the appliance has read the pressure and found it too low. F.73 means the appliance cannot get a sensible reading from the sensor at all — Vaillant describe it as the water pressure sensor signal being out of range at the low end, caused by a broken cable, a short circuit to 0V, or a defective sensor.
In other words, F.22 is about the water and F.73 is about the measurement. That distinction has a practical consequence: on an F.73 the pressure gauge will very often read perfectly normally, and topping the system up will change nothing at all. People frequently refill two or three times before working that out. The good news is that a pressure sensor and its wiring are among the cheaper repairs on a Vaillant, and the fault is straightforward for an engineer to confirm with a multimeter.
One generation words it the other way round, and it matters if you own one: the ecoTEC sustain manual prints F.73 as "water pressure sensor short-circuited" and gives the interruption — the broken cable — to F.74, which is the reverse of the ecoTEC plus and pro. The 2022 CS/1-5 has no F.073 at all; its F.074 covers the interrupted signal. Whichever way round your boiler prints it, the engineer's job is the same circuit.
What causes it
| Cause | What is actually happening | How likely |
|---|---|---|
| Pressure sensor failed | Gone open circuit or drifted outside the range the board will accept. The most likely explanation and a modest part cost. | Common |
| Cable to the sensor broken or shorted | Vaillant name a broken cable and a short to 0V specifically. A wiring fault is cheaper than a sensor and worth eliminating first. | Common |
| Connector corroded or unseated | Frequently follows previous work on the appliance, or damp inside the case. Costs nothing but the call-out if that is all it is. | Occasional |
| Control board input fault | The board cannot read a healthy sensor. Considered only after the sensor and its wiring have been measured. | Rare |
Can you fix it yourself?
Stop — this needs an engineer
What it costs to fix
Typical repair cost
£90–£260
A wiring or connector repair is a call-out charge of £80 to £150. A pressure sensor is £130 to £240 fitted.
Typical UK prices including parts and labour, updated September 2026. Your quote may differ.
Parts you may need
We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.
Vaillant ecoTEC water pressure sensor
0020059717£26–£54Authorised Vaillant parts distributor
Price checked 28 September 2026
Own this appliance and had this code? . Nothing is published until a person has read it.
Related Vaillant fault codes
- F.22Get it checkedThe boiler has shut down because there is not enough water in the system. Pressure has dropped below roughly 0.5 bar and it will not fire until you top it up.Related: water pressure
- F.75Get it checkedThe boiler cannot detect a rise in pressure when the pump starts, so it has locked out. Usually a failed pressure sensor or a pump that is not moving water.Related: water pressure
- S.53Get it checkedNot a fault. Your boiler is in a deliberate waiting period because the gap between flow and return temperatures is too wide, which points at poor circulation.Related: water pressure
- F.74Get it checkedThe water pressure sensor is sending a signal that is too high to be genuine. This is a wiring or sensor fault, not high system pressure.Related: water pressure
- S.76Get it checkedA service message, not a lockout: the heating water pressure has dropped and Vaillant want it topped up. The boiler is still running, but below 0.5 bar it will stop with F.22.Related: water pressure
- S.41Get it checkedA status, not a lockout: the heating water pressure is too high, above about 2.8 bar. Usually an over-filled system or a tired expansion vessel, and the safety valve will discharge above 3 bar.Related: water pressure
Own a Vaillant boiler? Save it and its codes come first next time.
Related guides
Technical review
Not reviewed by an engineer
No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.
Sources and how we verified this
We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.
- Manufacturer technical and service documentation
This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.