Vaillant S.41 status codewhat it means

Get it checkedBoilerecoTEC plus, pro, exclusive (with the 2.8 bar figure), 48–64 kW plus and ecoFIT pure, and the ecoTEC plus CS/1-5 as S.041. The 2005–2012 ecoTEC, ecoMAX and turboMAX plus tables have no high-pressure status; on those the safety valve is the only indication.Last updated

A status, not a lockout: the heating water pressure is too high, above about 2.8 bar. Usually an over-filled system or a tired expansion vessel, and the safety valve will discharge above 3 bar.

Take care

Some of this is safe to check yourself, but the repair itself is not. If the fault comes back after one reset, stop resetting it and get a Gas Safe registered engineer to look at the Vaillant properly.

What S.41 means

S.41 is the status "Water pressure too high — the system pressure is too high", and the ecoTEC exclusive manual gives the figure: "water pressure > 2.8 bar". The boiler is not locked out. It is telling you that the sealed heating system is carrying more pressure than it should, and that the next stop is the pressure relief valve, which opens at 3 bar and dumps water through the copper pipe that ends outside.

Vaillant's operating instructions for the ecoTEC sustain put the householder response in one line: "the system pressure is too high: > 0.3 MPa (> 3 bar) — wait until the excess heating water has flowed out through the expansion relief valve", which is honest about what will happen but not something to rely on twice, because a relief valve that has lifted often fails to reseal and then weeps for good. The two common causes are simple. The system was filled too far, to 2 bar or more when cold, so that ordinary expansion as it heats pushes it towards 3 bar; or the expansion vessel has lost the air charge that lets it absorb that expansion, so the pressure swings between low when cold and very high when hot.

A combi has a third route: a pinhole in the plate heat exchanger or a passing filling loop lets mains water at 3 or 4 bar creep into the heating side, and the pressure climbs over days with nothing switched on. F.74 is the fault version, raised when the pressure sensor's signal is too strong, and its remedy in the installer table is "drain water, check the water pressure sensor". The 2022 ecoTEC plus shows S.041.

What causes it

Causes of the Vaillant S.41 status code, most common first
CauseWhat is actually happeningHow likely
Over-filled when topping upFilled to 2 bar or above with the system cold. Heating it adds the best part of a bar, and 2.8 arrives before the radiators are hot.Common
Expansion vessel lost its chargeWithout air behind the diaphragm the vessel cannot absorb expansion. Pressure climbs steeply as the boiler heats and falls back when it cools, and the relief valve discharges each cycle.Common
Filling loop left open or passingA loop with both valves not fully closed, or a worn valve, feeds mains pressure into the heating. Pressure rises with the boiler off and keeps rising.Occasional
Plate heat exchanger leaking mains into the heatingA combi-only cause. A pinhole between the two sides lets cold mains through at mains pressure. Pressure creeps up over days, and hot water may run tepid at the same time.Rare

What to try yourself

  1. Check both valves on the filling loop are fully closed, and if your loop is the flexible detachable kind, that it is disconnected. Then read the pressure with the boiler cold. Vaillant's range is 1.0 to 2.0 bar cold; the top of the bar graph on the display marks 2.0.

  2. If it is above 2.0 bar cold and you filled it recently, let a little water out at a radiator bleed valve into a cloth or cup until the display reads about 1.2 to 1.5 bar. Do it slowly and stop early; it is easier to add than to remove.

    Do not open the boiler's pressure relief valve to lower the pressure. It rarely reseals properly once lifted by hand and will drip outside for good.
  3. Watch the pressure over the next few heating cycles. If it climbs above 2.5 bar every time the boiler is hot and falls back when cold, the expansion vessel needs recharging or replacing. If it climbs with the boiler off and the loop closed, water is getting in from the mains, and both are engineer's work.

Get a Gas Safe registered engineer to look at your Vaillant S.41

We do not pass enquiries to a repair firm, so there is no form here. Find a Gas Safe registered engineer through the Gas Safe Register, and ask to see their registration card when they arrive — it is the register, not the van, that tells you they are qualified.

What it costs to fix

Typical repair cost

£80–£450

Time on site

20 minutes

Letting a little water out costs nothing. Recharging the expansion vessel is £80 to £120; replacing it £180 to £300; a plate heat exchanger on a combi £250 to £450 fitted.

Typical UK prices including parts and labour, updated September 2026. Your quote may differ.

Parts you may need

We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.

Expansion vessel (8 litre, sealed system)

EV-8L£35–£85Plumbing merchant

Price checked 28 September 2026

Pressure relief valve, 3 bar

PRV-3B£18–£42Plumbing merchant

Price checked 28 September 2026

Vaillant ecoTEC water pressure sensor

0020059717£26–£54Authorised Vaillant parts distributor

Price checked 28 September 2026

Own this appliance and had this code? . Nothing is published until a person has read it.

Common questions about Vaillant S.41

Will the boiler stop?

Not at S.41; it is a status and the boiler carries on. Above 3 bar the safety valve opens and lets water out until the pressure falls. If the pressure sensor reads very high the boiler raises F.74 and does stop. Either way the cause wants fixing before the valve is asked to do that again.

It was fine for years. Why now?

Expansion vessels lose their air charge slowly through the diaphragm; most need re-pressurising after five to ten years. The first sign is a pressure that swings much more than it used to between cold and hot, and a puddle under the discharge pipe outside.

Can I keep letting water out?

As a one-off after over-filling, yes. As a routine, no: if you are bleeding water out every week, something is adding it, or the vessel is not absorbing expansion, and each cycle wears the safety valve and brings fresh, oxygenated water into the system.

Written by

Andrew Pickett

Researcher and writer

Last updated

Technical review

Not reviewed by an engineer

No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.

What we check instead

Sources and how we verified this

We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.

  • Manufacturer technical and service documentation

This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.

Read our full verification process

Was this page helpful?