Glow-worm F.9 fault codewhat it means and how to fix it

Get it checkedBoilerF9 on Ultracom hxi, cxi and sxi, Flexicom, Ultrapower and Xtramax HE · 09 on the CI, CI Plus and SI two-digit displays · not on the current F.xx ranges (F.73 and F.74 there) or the Ultracom2 and Betacom two-digit boardsLast updated

F9 on an Ultracom, Flexicom, Ultrapower or CI-range boiler is Glow-worm's water pressure sensor fault — on the hxi and Flexicom "or a blocked flow filter or pump fault". It is not the low-pressure code.

Take care

Some of this is safe to check yourself, but the repair itself is not. If the fault comes back after one reset, stop resetting it and get a Gas Safe registered engineer to look at the Glow-worm properly.

What F.9 means

F9 belongs to the F1-to-F77 generation: the Ultracom hxi, cxi and sxi, the Flexicom, the Ultrapower, the Xtramax HE and the CI, CI Plus and SI ranges. Glow-worm's trade tables give two versions of it. For the Ultracom hxi and the Flexicom it is "water pressure sensor fault, blocked flow filter or pump fault"; for the cxi, sxi, CI and SI ranges it is "water pressure sensor fault (please contact GW technical department for further information)".

The 24CI/18SI installation manual lists 09 on its two-digit display as "water pressure sensor fault", and separately lists a flashing pressure reading — "0.5bar", lack of water — for genuinely low pressure, which tells you F9 is the sensor's fault rather than the water's. On the Flexicom the low-pressure code is F22, and its user guide says so. This page used to say that F9 was simply the older name for F22 and could be cleared by repressurising; Glow-worm's current homeowner page does not say that, and no manual we have read says it, so the claim is withdrawn.

What the user guides for these ranges do let a householder do is read the pressure gauge, top up if it is below 1 bar, and press reset once. If F9 stays with the gauge reading normally, the sensor, the filter or the pump is the engineer's to find. The current F.xx ranges have no F.9; their sensor codes are F.73 and F.74.

What causes it

Causes of the Glow-worm F.9 fault code, most common first
CauseWhat is actually happeningHow likely
Water pressure sensor failed or disconnectedGlow-worm's first cause on every range that shows F9. The sensor is a small transducer on the hydraulic block inside the casing; a failed element or a plug knocked off gives the board no pressure it can trust.Common
Blocked flow filter — Ultracom hxi and FlexicomNamed in the hxi and Flexicom tables. Debris caught in the filter starves the sensor of a true reading when the pump runs, and the board reports the sensor rather than the sludge.Occasional
Pump fault — Ultracom hxi and FlexicomThe third clause in the same table entry. A pump that does not run, or runs without moving water, leaves the pressure signal flat where the board expects it to change. Overlaps with F73 on these ranges.Occasional
Pressure genuinely low as wellNot the code's meaning, but a system that has dropped below the sensor's range can show F9 rather than a flashing pressure. The gauge settles it, which is why the first step is to read it.Occasional

What to try yourself

  1. Read the pressure gauge on the boiler with the system cold. Glow-worm's Ultracom, Flexicom and Ultrapower user guides want it at or above 1 bar.

  2. If it is below 1 bar, top up through the filling loop as your user guide describes, to between 1 and 1.5 bar, and close and disconnect the loop afterwards.

  3. Press the reset button once. If F9 clears and stays clear, it was the pressure.

  4. If F9 returns with the gauge reading normally, stop there and book an engineer. Tell them the pressure reads correctly, because that points them at the sensor, the filter or the pump rather than the water.

    Do not keep resetting or topping up against a reading you cannot trust.

Get a Gas Safe registered engineer to look at your Glow-worm F.9

We do not pass enquiries to a repair firm, so there is no form here. Find a Gas Safe registered engineer through the Gas Safe Register, and ask to see their registration card when they arrive — it is the register, not the van, that tells you they are qualified.

What it costs to fix

Typical repair cost

£0–£300

Time on site

1 hour

Nothing if it was low pressure. A pressure sensor fitted £120–£240. A pump on an Ultracom or Flexicom £200–£300.

Typical UK prices including parts and labour, updated September 2026. Your quote may differ.

Parts you may need

We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.

Central heating circulating pump

CH-PUMP-15-60£90–£180Plumbing merchant

Price checked 28 September 2026

Magnetic system filter, 22mm

MAG-22£65–£120Plumbing merchant

Price checked 28 September 2026

Glow-worm water pressure sensor

£25–£60Authorised Glow-worm parts distributor

Price checked 28 September 2026

Own this appliance and had this code? . Nothing is published until a person has read it.

Common questions about Glow-worm F.9

Is F9 the old name for F22?

No. On the ranges that show F9 the low-pressure code is F22 — the Flexicom user guide lists both — and F9 is the pressure sensor itself. An earlier version of this page said otherwise on the strength of a sentence that is not in any Glow-worm document we can find.

The trade table says "contact GW technical department". What does that mean for me?

That Glow-worm did not publish a diagnostic for F9 on the cxi, sxi and CI ranges even for engineers. Expect the engineer to prove the sensor and its wiring, and to ring Glow-worm if that does not resolve it.

Will a magnetic filter help?

On the hxi and Flexicom, where Glow-worm name a blocked flow filter, keeping debris out of the system is the long-term answer. That is a system decision for the engineer, not a Glow-worm instruction for F9.

Written by

Andrew Pickett

Researcher and writer

Last updated

Technical review

Not reviewed by an engineer

No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.

What we check instead

Sources and how we verified this

We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.

  • Manufacturer technical and service documentation
  • Manufacturer support portal

This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.

Read our full verification process