On Ultracom, Flexicom and Ultrapower boilers F1 is an ignition lockout after five failed attempts, and Glow-worm's guides let you reset it. On Energy and Ultimate boilers F.01 is the return sensor instead.
Take care
Which boiler, and what have you checked?
The right answer depends on what you can see. Pick the one that matches.
Choose the option on the left that matches what your appliance is doing, and the answer for that case appears here.
Older boiler, and the gas is off or the meter is empty
Restore the supply and reset once. The boiler was never at fault.
Older boiler, gas fine, condensate clear, F1 returns after a reset
Electrode, spark lead or gas valve. Glow-worm's guide says contact your servicing company at this point.
Book a Gas Safe registered engineer. Do not keep resetting.
F.01 with a stop, or F01 on a two-digit display
Return temperature sensor circuit. A cheap part, but inside the casing.
Engineer visit; no householder action changes this one.
What F1 means
Two boilers, one number, and the display tells you which you have. If yours is an Ultracom cxi, hxi or sxi, a Flexicom cx, hx or sx or an Ultrapower sxi — a flashing F and a single digit on a small LCD — Glow-worm's user guides define F1 in one line: "Boiler has attempted to light 5 times and failed on all occasions. Press the reset button. If the fault persists, contact your Installation/Servicing company or Glow-worm." The trade tables for those ranges, and for the 24CI, 18SI, 30ci Plus, Xtramax HE and Ultracom cx before them, all list F1 as "ignition fault"; the CI-era boilers showed it as 01 with the letter F and a flashing red light.
The same guides give the householder two things to check around it: the switching-on section says to "check that the water and gas isolating valves on the appliance are open", and the condensate section says the boiler stops if the drain is blocked and that an ice blockage can be released "by the use of warm cloths on the pipe", after which "the boiler should then restart". Glow-worm's current homeowner page gives the same checks, plus prepayment credit, for the modern equivalent F.28.
If instead your boiler is an Energy, Ultimate3, Easicom, Betacom3 or 4 or Compact showing F.01 with a stop, or an Ultracom2 or Betacom2 showing F01, the code has nothing to do with ignition: it is "Fault: Return temperature sensor", the return NTC unplugged, its plug loose on the board, a break in the harness or the sensor itself failed, and that half of the page is an engineer's job. The five attempts of the old F1 against the three of the new F.28 is a genuine difference between the generations, not a transcription slip.
What causes it
| Cause | What is actually happening | How likely |
|---|---|---|
| No gas at the boiler — older ranges | The CI-era table defines 01 as an ignition lockout "caused by no gas, no detection". A closed isolator, a supply interruption or a prepayment meter out of credit produce five failed attempts and F1 with nothing else wrong. | Common |
| Condensate pipe frozen or blocked — older ranges | The Flexicom and Ultracom guides say the boiler stops when the condensate drain is blocked and carry a section on releasing an ice blockage with warm cloths. Condensate that cannot drain backs into the chamber and the burner will not establish. | Common |
| Electrode, lead or spark generator worn — older ranges | These boilers are ten to twenty years old, and an electrode that has eroded or a spark lead that has cracked is the usual finding once the gas is proven. Engineer-only, but not expensive. | Common |
| Return temperature sensor open circuit — F.01 on current ranges | Glow-worm's causes are the NTC plug loose or off, the multiple plug on the PCB not seated, a break in the harness, or the sensor defective. Nothing to do with lighting; the boiler will not run without a return reading. | Occasional |
What to try yourself
Identify the display. A single-digit F1 with a flashing F on an Ultracom, Flexicom or Ultrapower is the ignition lockout and the steps below apply. F.01 with a stop, or F01 on an Ultracom2 or Betacom2, is the return sensor — skip to calling an engineer.
Check the gas supply: does the hob light, is the meter in credit, is the gas isolating valve under the boiler open? The guides ask for it open before switching on, and a lockout after five attempts with no gas is not a boiler fault.
Trace the condensate pipe outside and free any frozen section with warm cloths, which is the method the Flexicom and Ultracom guides give. Warm, not boiling — the Betacom2 guide adds that warning for the same job.
Press the reset button on the fascia once. The guide says the boiler should return to operation if the supply or the pipe was the problem; if F1 returns, leave it switched off and call your installer or a Gas Safe registered engineer, because five more attempts have already been made for you.
Get a Gas Safe registered engineer to look at your Glow-worm F1
We do not pass enquiries to a repair firm, so there is no form here. Find a Gas Safe registered engineer through the Gas Safe Register, and ask to see their registration card when they arrive — it is the register, not the van, that tells you they are qualified.
What it costs to fix
Typical repair cost
£0–£400
Time on site
20 minutes
Free if it was gas credit or a frozen pipe. Electrode £90–£170. Return sensor (F.01) £90–£160. Gas valve £250–£400.
Typical UK prices including parts and labour, updated September 2026. Your quote may differ.
Parts you may need
We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.
Condensate trap and siphon
COND-TRAP£15–£38Plumbing merchant
Price checked 28 September 2026
Glow-worm flow or return temperature sensor (clip-on NTC)
£12–£35Authorised Glow-worm parts distributor
Price checked 28 September 2026
Glow-worm ignition and flame-sensing electrode
£18–£45Authorised Glow-worm parts distributor
Price checked 28 September 2026
Own this appliance and had this code? . Nothing is published until a person has read it.
Related Glow-worm fault codes
- F.28Get it checkedThree ignition attempts have failed and the boiler has locked out. Glow-worm's guides let you check the gas supply and the condensate pipe and reset three times before calling anyone.Related: ignition and gas supply
- F.29Get it checkedThe burner lit and then the flame went out while running. Glow-worm blame the gas supply, flue gas recirculating, earthing, the spark transformer and, on newer manuals, a blocked condensate pipe.Related: ignition and gas supply
- F.61Get it checkedThe board cannot drive the gas valve properly — a short in its wiring, coils shorted to earth, or the electronics. The valve stays shut until an engineer has traced it.Related: ignition and gas supply
- F.27Stop — call an engineerThe boiler is sensing a flame when there should not be one. Glow-worm list moisture on the electronics, a failed flame monitor or a leaking gas valve. Not a reset job.Related: ignition and gas supply
- F.68Get it checkedThe flame is burning but its signal is unstable. Glow-worm list air in the gas, low gas pressure, a wrong combustion setting or injector, a poor electrode connection or a blocked condensate pipe.Related: ignition and gas supply
- F.62Stop — call an engineerThe gas valve did not shut off when told to — the flame signal lingered after the close command. Glow-worm list a delayed or leaking valve or the electronics. Switch off; call an engineer.Related: ignition and gas supply
Own a Glow-worm boiler? Save it and its codes come first next time.
Related guides
Common questions about Glow-worm F1
Why five attempts on the Flexicom but three on the Energy?
Different generations of board. The Flexicom, Ultracom and Ultrapower guides say five; the Energy7, Ultimate3 and Betacom4 guides say three before F.28 and then allow three resets. Both are Glow-worm's own figures.
My Betacom shows F1 with two digits, F01. Which is it?
The two-digit displays of the Ultracom2, Betacom 24a/28a and Betacom2 use F01 for the return sensor and F28 for ignition. So F01 on those is the sensor, not the lockout.
How much for the older boilers?
An electrode is typically £90–£170 fitted on these ranges; a spark generator similar. If it is the gas valve, £250–£400, and on a boiler this age an engineer may talk to you about whether that is worth doing.
Technical review
Not reviewed by an engineer
No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.
Sources and how we verified this
We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.
- Manufacturer technical and service documentation
- Manufacturer support portal
This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.