Skip to content
FaultcodeCheck

Glow-worm F.68 fault codewhat it means and how to fix it

Get it checkedBoilerF.68 on Energy, Ultimate, Easicom, Betacom3/4 and Compact · F68 on Ultracom2, Betacom 24a/28a and Betacom2Last updated

The flame is burning but its signal is unstable. Glow-worm list air in the gas, low gas pressure, a wrong combustion setting or injector, a poor electrode connection or a blocked condensate pipe.

Take care

Some of this is safe to check yourself, but the repair itself is not. If the fault comes back after one reset, stop resetting it and get a Gas Safe registered engineer to look at the Glow-worm properly.

Get a Gas Safe registered engineer to look at your Glow-worm F.68

We do not pass enquiries to a repair firm, so there is no form here. Find a Gas Safe registered engineer through the Gas Safe Register, and ask to see their registration card when they arrive — it is the register, not the van, that tells you they are qualified.

What F.68 means

Glow-worm call F.68 "Fault: Unstable flame (analogue input)" and, on the two-digit boilers, "fluctuation of flame signal". The burner lit and is being held, but the ionisation current the electrode reports is wandering rather than steady, and after enough of that the board gives up.

The published causes are "air in gas, gas flow pressure too low, incorrect air ratio, incorrect gas injector, ionisation flow interruption (cable, electrode)", and the Compact manual adds flue gas recirculation and a blocked condensate discharge pipe, and against the air-in-gas cause it tells the engineer to "reset the unit once" — the one place Glow-worm sanction a reset for this code, and only in the installer's document. That is what F.68 often is after a gas supply has been off: air in the pipe gives a ragged flame for the first burn and a single reset clears it. The other causes are not like that. A combustion setting that has drifted, an injector left from a different gas type, or an electrode with a poor connection produce a flame that is permanently marginal, and the boiler will keep finding it.

The Betacom2 manual gives the engineer the same checks it gives for F28 — gas circuit, flame picture and CO2, igniter connections, electrode condition — which tells you how Glow-worm think of F.68: the ignition fault that nearly worked. It is a combustion code, and combustion adjustment on a Glow-worm is an analyser job for a Gas Safe registered engineer.

What causes it

Causes of the Glow-worm F.68 fault code, most common first
CauseWhat is actually happeningHow likely
Air in the gas supplyAfter a meter change, a supply interruption or work on the pipework. The Compact manual's remedy is a single reset, and if the flame steadies the fault was never in the boiler.Common
Gas pressure low at the boilerGlow-worm's second cause. A supply that sags at peak demand, a long undersized run or a partly closed valve leaves the burner hunting, and the signal fluctuates with it.Common
Combustion ratio or injector wrongThe CO2 setting has drifted or the wrong injector is fitted. The Betacom2 manual tells the engineer to observe the flame picture and check the CO2; that needs an analyser.Occasional
Electrode or lead connection poorGlow-worm's "ionisation flow interruption (cable, electrode)". A corroded terminal or a cracked ceramic gives a signal that comes and goes with vibration and heat.Occasional

Can you fix it yourself?

What it costs to fix

Typical repair cost

£80–£400

Time on site

1 hour

Combustion check and adjustment £80–£150. Electrode £90–£180. Gas valve £250–£400 if the pressure regulation has failed.

Typical UK prices including parts and labour, updated September 2026. Your quote may differ.

Parts you may need

We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.

Condensate trap and siphon

COND-TRAP£15–£38Plumbing merchant

Price checked 28 September 2026

Glow-worm ignition and flame-sensing electrode

£18–£45Authorised Glow-worm parts distributor

Price checked 28 September 2026

Glow-worm gas valve assembly

£90–£200Authorised Glow-worm parts distributor

Price checked 28 September 2026

Own this appliance and had this code? . Nothing is published until a person has read it.

Own a Glow-worm boiler? Save it and its codes come first next time.

Common questions about Glow-worm F.68

Can I reset it once?

Glow-worm's Compact installation manual says a single reset is the measure for air in the gas, and the user guides reserve the code for a competent person. One reset after a known supply interruption is reasonable; a second is not.

Is F.68 the same fault as F.28?

Cousins. F.28 is a flame that never established; F.68 is one that did but cannot hold a steady signal. Glow-worm give the engineer almost the same checklist for both on the Betacom2.

Could it be the condensate pipe?

The Compact manual lists a blocked condensate discharge pipe against F.68, F.28 and F.29 alike. In freezing weather the outdoor pipe is worth a look before anyone is called.

Written by

Andrew Pickett

Researcher and writer

Last updated

Technical review

Not reviewed by an engineer

No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.

What we check instead

Sources and how we verified this

We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.

  • Manufacturer technical and service documentation

This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.

Read our full verification process

Was this page helpful?