Glow-worm F.28 fault codewhat it means and how to fix it

Get it checkedBoilerF.28 on Energy, Ultimate, Easicom, Betacom3/4 and Compact · F28 on Ultracom2, Betacom 24a/28a and Betacom2 · shown as F1 on Ultracom, Flexicom, Ultrapower and the CI rangesLast updated

Three ignition attempts have failed and the boiler has locked out. Glow-worm's guides let you check the gas supply and the condensate pipe and reset three times before calling anyone.

Take care

Some of this is safe to check yourself, but the repair itself is not. If the fault comes back after one reset, stop resetting it and get a Gas Safe registered engineer to look at the Glow-worm properly.

What else is true in the house right now?

The right answer depends on what you can see. Pick the one that matches.

Choose the option on the left that matches what your appliance is doing, and the answer for that case appears here.

The hob will not light either, or the meter is out of credit

Not a boiler fault. Restore the supply, then reset once.

Contact the gas supplier if the meter is in credit and still nothing lights.

It is below freezing and the condensate pipe runs outside

A frozen condensate pipe is Glow-worm's own listed cause. Thaw it and reset once.

Gas is fine, it is mild, and the third reset has failed

The fault is inside the boiler — electrode, gas valve or board.

Book a Gas Safe registered engineer and leave the boiler off.

You can smell gas

Do not reset again.

Leave the property and call 0800 111 999 from outside.

What F.28 means

Glow-worm print F.28 as "Fault: Ignition unsuccessful when starting up", and the operating instructions for the Energy7, Ultimate3 and Betacom4 all explain how you got there: "after three unsuccessful ignition attempts, the product switches to fault mode". The boiler has already tried three times before you see the code. The installation manuals then give the longest cause list in the whole table — a gas meter fault or gas pressure switch that has tripped, air in the gas, gas pressure too low, a thermal cut-out, the wrong gas injector, a wrong or faulty gas valve, a plug not seated on the board, a break in the harness, the ignition transformer, cable, plug or electrode, an interrupted ionisation signal, poor earthing, or the electronics — and the Energy7 and Compact editions add one more that is yours to check: a blocked condensate siphon or discharge pipe.

The Compact user guide is the most helpful Glow-worm document on this code. It tells the householder to check the gas stopcock is open, to "check at the gas meter that gas is still being supplied", adding that "if you have not topped up your payment recently, the gas supply could be cut off by the meter", and only then to call a competent person.

Glow-worm's homeowner fault-code page gives the same three checks — other gas appliances, prepayment credit, ice in an outdoor condensate pipe — and adds the electrode, the PCB and the flue to the causes. The Ultracom2 and Betacom2 tables also carry F28, with no gas or insufficient gas flow, a mis-set gas valve and a defective electrode or igniter as the causes, and the Betacom 24a installation manual adds a warning worth repeating: do not use the reset button to purge the gas line, and never press it more than three times.

What causes it

Causes of the Glow-worm F.28 fault code, most common first
CauseWhat is actually happeningHow likely
No gas reaching the boilerA prepayment meter out of credit, a gas stopcock knocked shut, or a supply interruption. Glow-worm's Compact guide names the meter payment specifically, and it is the commonest reason a boiler that was fine yesterday will not light today.Common
Condensate siphon or pipe blocked or frozenListed by Glow-worm against F.28 on the Energy7 and Compact. Water backs up into the combustion chamber and the burner cannot light. In frost the external pipe is the place to look; in summer a siphon full of sludge does the same.Common
Electrode worn, cracked or badly earthedThe spark is weak or the flame is not sensed once lit, so the attempt is counted as a failure. Glow-worm list the electrode, its cable and the earthing of the product together, and this is the usual finding when the gas supply is proven.Common
Gas valve, injector or pressure faultGas pressure too low at the boiler, a gas valve that will not open cleanly, or the wrong injector after a conversion. Engineer-only, and the dearer end of the list.Occasional

What to try yourself

  1. Check the gas. Will the hob light? Is a prepayment meter in credit, including emergency credit that may have run out? Is the gas isolator under the boiler fully open? Glow-worm's Compact guide puts these first for a reason.

  2. Follow the condensate pipe — the plastic pipe leaving the bottom of the boiler — to where it discharges. If it runs outside and the weather has been freezing, feel for a solid, cold section and thaw it with warm water, not boiling.

  3. Reset as your guide says: press the reset button for one second on an Energy7, press the button on an Ultimate3 or Betacom4, hold the on/off button for more than three seconds on a Compact. The boiler makes a fresh ignition attempt.

    Glow-worm allow three resets. Each one runs the full ignition sequence with the gas valve open, and the Betacom 24a manual says outright never to press reset more than three times. If it is still F.28 after three, stop.
  4. Call a Gas Safe registered engineer if the third reset fails, and tell them whether the gas and condensate checks were clear — that saves the first twenty minutes of the visit.

Get a Gas Safe registered engineer to look at your Glow-worm F.28

We do not pass enquiries to a repair firm, so there is no form here. Find a Gas Safe registered engineer through the Gas Safe Register, and ask to see their registration card when they arrive — it is the register, not the van, that tells you they are qualified.

What it costs to fix

Typical repair cost

£0–£400

Time on site

20 minutes

Free if it was gas credit or a frozen pipe. Electrode £90–£180. Gas valve £250–£400 fitted.

Typical UK prices including parts and labour, updated September 2026. Your quote may differ.

Parts you may need

We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.

Condensate trap and siphon

COND-TRAP£15–£38Plumbing merchant

Price checked 28 September 2026

Glow-worm ignition and flame-sensing electrode

£18–£45Authorised Glow-worm parts distributor

Price checked 28 September 2026

Glow-worm gas valve assembly

£90–£200Authorised Glow-worm parts distributor

Price checked 28 September 2026

Own this appliance and had this code? . Nothing is published until a person has read it.

Own a Glow-worm boiler? Save it and its codes come first next time.

Common questions about Glow-worm F.28

Why did it only fail this morning?

Overnight is when the condensate pipe is coldest, the gas main pressure is lowest and a marginal electrode has cooled fully. A boiler that locks out first thing and runs after one reset is telling you a fault is developing, not that it has a quirk.

My older Glow-worm shows F1, not F.28. Same thing?

Same event, different generation. The Flexicom, Ultracom and Ultrapower guides define F1 as the boiler having attempted to light five times and failed, and their trade tables print it as an ignition fault. The F1 page here covers those boilers.

What will an engineer charge?

A diagnostic visit £80–£130. An electrode £90–£180 fitted, a gas valve £250–£400. Clearing a condensate blockage is cheap; re-routing an outdoor pipe so it stops freezing is £120–£250.

Written by

Andrew Pickett

Researcher and writer

Last updated

Technical review

Not reviewed by an engineer

No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.

What we check instead

Sources and how we verified this

We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.

  • Manufacturer technical and service documentation
  • Manufacturer support portal

This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.

Read our full verification process

Was this page helpful?